2-66
C122-E001-10EN
CHAPTER 2 Setup
2.5.8
Setting various modes
This function sets the PCI address mode (only for PRIMEQUEST 580A/540A/580/
540/480/440) for a partition, the System Mirror Mode, and the Hyper Threading
Mode (only for PRIMEQUEST 500A/500 series).
Note the following about setting XPAR mode:
Notes:
•
Extended Mirror Mode cannot be set in partitions containing SBs, IO Units or
IOXs split with XPAR set. No split SB, IO Unit, or IOX can be assigned to a
partition that is set in Extended Mirror Mode.
•
No SB split with XPAR set can be assigned as the reserved SB of a partition that
is set in Extended Mirror Mode. Extended Mirror Mode cannot be set in
partitions to which split SBs are assigned as reserved SBs.
•
XPAR is supported only in the PRIMEQUEST 500A/500 series, and the XPAR
option is required for setting XPAR.
Procedure
1
Click [Partition]
→
[Partition#x]
→
[Mode].
The [Mode] window is displayed.
Figure 2.44 [Mode] window (PRIMEQUEST 580A/540A)