background image

CHAPTER 1 Product Overview 
1.3 PRIMEQUEST 2000 series configuration 

 

CA92344-0534-07 

1.3 

PRIMEQUEST 2000 series configuration  

The following figure shows a conceptual diagram of the configuration of the PRIMEQUEST 2000 series.  

FIGURE 1.4 Configuration conceptual diagram 

 

 

 

Summary of Contents for PRIMEQUEST 2400E3

Page 1: ...CA92344 0534 07 FUJITSU Server PRIMEQUEST 2000 Series General Description ...

Page 2: ...titioning functions including PPAR and Flexible I O used in the PRIMEQUEST 2000 series CHAPTER 6 Redundancy Chapter 6 describes the redundancy of components for the PRIMEQUEST 2000 series CHAPTER 7 Applicable Components for Hot Maintenance Chapter 7 describes the hot maintenance of hardware components for the PRIMEQUEST 2000 series CHAPTER 8 Operations Management Tools Chapter 8 provides an overvi...

Page 3: ...mation in the PRIMEQUEST 2000 Series Hardware Installation Manual Appendix F Tree Structure of the MIB provided with the PRIMEQUEST 2000 series Appendix F provides a link to Appendix H Tree Structure of the MIB Provided with the PRIMEQUEST 2000 Series in the PRIMEQUEST 2000 Series Administration Manual Appendix G Linkage functions and Services Appendix G describes the linkage functions and service...

Page 4: ...t PRIMEQUEST 2400E2 2800E2 2800B2 Added description about Memory Scale up Board and Extended Socket 05 2015 09 29 All pages Added description about LDAP 06 2015 10 30 All page modified description about Memory Scale up Board 07 2016 05 30 All page Added description about PRIMEQUEST 2400E3 2800E3 2800B3 Added description about Address Range Mirror 1 Chapter section and item numbers in the Revised l...

Page 5: ...f the user does not perform the procedure correctly This indicates information that could help the user use the product more efficiently Alert messages in the text An alert statement follows an alert symbol An alert statement is indented on both ends to distinguish it from regular text Similarly one space line is inserted before and after the alert statement Only Fujitsu certified service engineer...

Page 6: ...Preface v CA92344 0534 07 Warning label location the main cabinet top ...

Page 7: ...Preface vi CA92344 0534 07 Warning label location the main cabinet left Warning label location PCI_Box ...

Page 8: ...not guaranteed to operate with any optional product not certified by Fujitsu Exportation release of this product Exportation release of this product may require necessary procedures in accordance with the regulations of the Foreign Exchange and Foreign Trade Control Law of Japan and or US export control laws Maintenance Only Fujitsu certified service engineers should perform the following tasks on...

Page 9: ...ssary Support and service Product and service inquiries For all product use and technical inquiries contact the distributor where you purchased your product or a Fujitsu sales representative or systems engineer SE If you do not know the appropriate contact address for inquiries about the PRIMEQUEST 2000 series use the Fujitsu contact line Fujitsu contact line We acceptWeb inquiries For details vis...

Page 10: ...ary information and concepts you should understand for installation and facility planning for SPARC Enterprise and PRIMEQUEST installations C120 H007EN PRIMEQUEST 2000 Series Hardware Installation Manual Includes the specifications of and the installation location requirements for the PRIMEQUEST 2000 series CA92344 0535 PRIMEQUEST 2000 Series Installation Manual Describes how to set up the PRIMEQU...

Page 11: ...ibes the user interface of ServerView Operations Manager ServerView Suite ServerView RAID Management User Manual Describes RAID management using ServerView RAID Manager ServerView Suite Basic Concepts Describes basic concepts about ServerView Suite ServerView Operations Manager Installation ServerView Agents for Linux Describes installation and update installation of ServerView Linux Agent ServerV...

Page 12: ...t Windows Server 2008 R2 Standard Windows Windows Server 2008 R2 Microsoft Windows Server 2008 R2 Enterprise Microsoft Windows Server 2008 R2 Datacenter Red Hat Enterprise Linux 7 for Intel64 Linux RHEL7 Red Hat Enterprise Linux 6 for Intel64 Linux RHEL6 Oracle Linux 6 x86_64 Oracle Linux Oracle Linux 6 VMware vSphere 6 VMware vSphere 6 x VMware 6 VMware 6 x VMware ESXi TM 6 ESX ESX 6 ESX 6 x VMwa...

Page 13: ...s in this manual Notation This manual uses the following fonts and symbols to express specific types of information Font or symbols Meaning Example italics Title of a manual that you should refer to See the PRIMEQUEST 2000 Series Installation Manual CA92344 0536 Window names as well as the names of buttons tabs and drop down menus in windows are enclosed in brackets Click the OK button Notation fo...

Page 14: ...ly referred to as IO Units Screenshots contained in this manual may differ from the actual product screen displays The IP addresses configuration information and other such information contained in this manual are display examples and differ from that for actual operation The PDF file of this manual is intended for display using Adobe Reader in single page viewing mode at 100 zoom This manual shal...

Page 15: ...ction 20 1 4 7 Hardware RAID 21 1 4 8 PCI Hot Plug Function 21 1 4 9 Security and Encryption Function 21 1 4 10 Trusted Platform Module TPM 21 1 4 11 Secure Boot 22 1 4 12 Physical Partitioning PPAR 22 1 4 13 Extended Partitioning 22 1 4 14 Extended Socket 22 1 4 15 Dynamic Reconfiguration DR function 22 1 4 16 Flexible I O 23 1 4 17 Memory Scale up Board 23 1 4 18 Virtual Support Virtualization T...

Page 16: ...upport CPU list 43 2 4 DIMM Memory module 44 2 4 1 Supported DIMM 44 2 4 2 DIMM slot locations 44 2 4 3 DIMM installation group 45 2 5 SB System board 45 2 5 1 SB specifications 45 2 5 2 USB 51 2 5 3 VGA 52 2 6 Memory Scale up Board 52 2 6 1 Memory Scale up Board specifications 52 2 7 MMB Management Board 53 2 7 1 MMB specifications 54 2 7 2 MMB serial interface 55 2 7 3 MMB LAN interface 55 2 8 I...

Page 17: ... CHAPTER 3 3 1 Bundled electronic media 75 3 2 OS 75 3 3 Bundled software 76 3 4 Supplied Drivers 76 3 5 Firmware 77 3 6 Operations Management Software 77 Functions provided by the PRIMEQUEST 2000 series 78 CHAPTER 4 4 1 Basic Architecture 78 4 2 Management with MMB 78 4 2 1 MMB functions 78 4 2 2 MMB firmware 79 4 2 3 User account management of MMB 79 4 2 4 MMB operating environment 80 4 2 5 Hard...

Page 18: ...ocket 95 5 5 Memory Scale up Board 95 5 6 Reserved SB 95 5 7 Partition configuration definition method 96 5 8 Notes on the partition configuration 96 5 9 Dynamic Reconfiguration Function 96 5 10 Flexible I O Mode 96 5 11 Home SB 97 Redundancy 99 CHAPTER 6 6 1 Redundancy 99 6 2 Redundancy of components 99 6 3 Redundancy of HDD 99 6 3 1 Redundancy of the disk 99 6 4 Redundancy of the Management LAN ...

Page 19: ...e Customer Support System REMCS 115 Appendix H Right or wrong of combination of each function 116 H 1 Right or wrong of combination of each function in Microsoft Windows Server 2012 R2 116 H 2 Right or wrong of combination of each function in Microsoft Windows Server 2012 117 H 3 Right or wrong of combination of each function in Microsoft Windows Server 2008 R2 64bit 118 H 4 Right or wrong of comb...

Page 20: ...QUEST 2800B front view 41 FIGURE 2 9 PRIMEQUEST 2800B3 2800B2 2800B rear view 41 FIGURE 2 10 PRIMEQUEST 2800B3 2800B2 2800B top view 42 FIGURE 2 11 PRIMEQUEST 2800B3 2800B2 2800B right view 42 FIGURE 2 12 PRIMEQUEST 2800B3 2800B2 perspective view 42 FIGURE 2 13 PRIMEQUEST 2800B perspective view 43 FIGURE 2 14 SB External view 2400E3 2800E3 2400E2 2800E2 47 FIGURE 2 15 SB External view 2800B3 2800B...

Page 21: ...e of configuration display screen 81 FIGURE 4 5 Example of mounting different OS and versions on each partition 82 FIGURE 4 6 REMCS Automatic report function 83 FIGURE 4 7 Diagram of time synchronization of three 3 NTP servers 86 FIGURE 4 8 Flow of Proactive monitoring 88 FIGURE 4 9 Sadump conceptual diagram 89 FIGURE 5 1 Conceptual diagram of the partitioning PRIMEQUEST 2400E3 2400E2 92 FIGURE 5 ...

Page 22: ... 2 8 Memory Scale up Board specifications 52 TABLE 2 9 MMB specifications 54 TABLE 2 10 IOU_1GbE IOU_10GbE specifications 56 TABLE 2 11 The specification of the IOU built in LAN Controller 56 TABLE 2 12 Connection of IOU with DU 58 TABLE 2 13 DU specifications 59 TABLE 2 14 HDD bays in the SB and the HDD specifications of the DU PRIMEQUEST 2400E3 2800E3 2800B3 2400E2 2800E2 2800B2 61 TABLE 2 15 HD...

Page 23: ... 1 System disk redundancy 99 TABLE 8 1 List of SVS function manuals 104 Table H 1 Right or wrong of combination of each function in Microsoft Windows Server 2012 R2 116 Table H 2 Right or wrong of combination of each function in Microsoft Windows Server 2012 117 Table H 3 Right or wrong of combination of each function in Microsoft Windows Server 2008 R2 64bit 118 Table H 4 Right or wrong of combin...

Page 24: ...0E3 2800B3 High availability The following are supported as the memory functions Bank DDDC Memory Patrol Scrub Full Memory Mirror Partial Memory Mirror Address Range Mirror Memory Sparing Support of degradation operation function so that the system can operate by isolating the faulty CPU cores or SBs Support of hardware RAID Support of software RAID Support of Reserved SB functions Operations supp...

Page 25: ...DIMM and SSD Use of high efficiency power supply 80plus platinum Precision control of cooling fan rotation speed Support of Power Saving function Compliance with RoHS regulation 2011 65 EU 1 1 2 PRIMEQUEST 2400E2 2800E2 2800B2 Features The features of the PRIMEQUEST 2400E2 2800E2 2800B2 are given below High reliability and high performance Use of Intel Xeon processor E7 v3 product family SMP syste...

Page 26: ...ted Memory Scale up Board See 5 5 Memory Scale up Board Supported Not Supported Not Supported Virtualization support Support of Intel Virtualization Technology VT x VT d Support of APIC virtualization APICv Green compliance Power saving Control of power optimization Control of the device cooling airflow with flap Optimization of cooling by group partition in the cabinet Support of power efficiency...

Page 27: ... 5 10 Flexible I O Mode Supported Supported Not Supported Support of Extended Partitioning See 5 3 Extended Partitioning Supported Supported Not Supported Support of Extended Socket See 5 4 Extended Socket Supported Supported Not Supported Support of Dynamic Reconfiguration See 5 9 Dynamic Reconfiguration Function Supported Supported Not Supported Memory Scale up Board See 5 5 Memory Scale up Boar...

Page 28: ... sockets Business model PRIMEQUEST 2400E2 4 sockets Enterprise model PRIMEQUEST 2800E2 8 sockets Enterprise model PRIMEQUEST 2800B2 8 sockets Business model PRIMEQUEST 2400E 4 sockets Enterprise model PRIMEQUEST 2800E 8 sockets Enterprise model PRIMEQUEST 2800B 8 sockets Business model The external view is shown below For details on the conceptual diagram see 2 2 Base cabinet FIGURE 1 1 External O...

Page 29: ...CHAPTER 1 Product Overview 1 2 Product Lineup 6 CA92344 0534 07 FIGURE 1 2 External Overview of 2800B3 2800B2 FIGURE 1 3 External Overview of 2800B ...

Page 30: ...MEQUEST 2000 series configuration 7 CA92344 0534 07 1 3 PRIMEQUEST 2000 series configuration The following figure shows a conceptual diagram of the configuration of the PRIMEQUEST 2000 series FIGURE 1 4 Configuration conceptual diagram ...

Page 31: ...can be mounted to each SB Up to two SBs can be mounted Up to three Memory Scale up Boards can be mounted 1 Up to four HDDs can be mounted to each SB Up to four sockets SMP Up to two physical partitions PPAR Main hardware configuration Number of connected IOUs 4 Number of connected DUs 2 Number of PCI_Boxes 4 1 Only PRIMEQUEST 2400E3 2400E2 support Memory Scale up Board FIGURE 1 5 Hardware configur...

Page 32: ...00E2 2800E are as below Up to two CPUs can be mounted to each SB Up to four SBs can be mounted Up to four HDDs can be mounted to each SB Up to eight sockets SMPs Up to four physical partitions PPAR Main hardware configuration Number of connected IOUs 4 Number of connected DUs 2 Number of PCI_Boxes 4 FIGURE 1 6 Hardware configuration image PRIMEQUEST 2800E3 2800E2 2800E ...

Page 33: ... 2800B2 2800B Features of the PRIMEQUEST 2800B3 2800B2 2800B are as below Up to two CPUs can be mounted to each SB Up to four SBs can be mounted Up to eight sockets SMPs Main hardware configuration Number of connected IOUs 4 Number of connected DUs 2 FIGURE 1 7 Hardware configuration image PRIMEQUEST 2800B3 2800B2 2800B ...

Page 34: ...DR4 LRDIMM 8GB 16GB 32GB 64GB 128GB Maximum capacity 12 TB 128 GB 24 TB 128 GB 4 24 TB 128 GB Speed 1333 MT s 1600 MT s 1866 MT s Memory protection function ECC SDDC Bank DDDC Memory mirror Partial mirror Full mirror Address range mirror Memory spare 1 2 3 rank spare supported Maximum number of partitions PPAR 2 4 1 Dynamic Reconfiguration DR Supported Flexible I O Supported Reserved SB Supported ...

Page 35: ...support MMB redundancy For details on the device specifications environment conditions and power conditions of the PRIMEQUEST 2000 series see PRIMEQUEST 2000 series hardware installation manual CA92344 0535 TABLE 1 2 Hardware specifications PRIMEQUEST 2400E2 2800E2 2800B2 PRIMEQUEST 2400E2 2800E2 2800B2 Number of mounted SBs 2 4 4 Number of mounted Memory Scale up Boards 3 1 0 0 Number of mounted ...

Page 36: ...upport N 1 N N Dual power feed External dimensions mm in Width 445 17 52 Depth 782 30 79 Height 438 17 25 Number of occupied units 10U Weight kg lb 124 273 150 331 143 315 1 Total number of SB and Memory Scale up Board is up to four boards 2 Since supported CPU differs depending on PRIMEQUEST model see 2 3 1 Support CPU list 3 Since these values differ depending on CPU model see 2 3 1 Support CPU ...

Page 37: ...xpress Gen3 3 Up to 56 4x IOU_1GbE 4x PCI_Box Up to 16 4x IOU_1GbE Onboard device Dual GbE on IOU_1GbE Dual 10GbE on IOU_10GbE KVM interface 4 External USB USB2 0 4 port SB VGA 25 pin analog VGA 1 port SB Video redirection function Supported Virtual media function Supported Redundancy supported hardware PSU fan HDD PCI Express card CLK MMB 5 power input system Hot replacement supported components ...

Page 38: ...ions see 4 2 6 Partition settings and configuration display 1 3 4 Hardware management The Management Board MMB is provided as a mechanism for managing the hardware of the entire PRIMEQUEST 2000 series The MMB console 1 the Field Support Tool FST 2 and an external network can be connected through a LAN connection from the MMB 1 Console for setting up and displaying each hardware resource 2 Console ...

Page 39: ...onnection FcoE boot and FCoE connection Wake on LAN WOL Technologies that facilitate administration Centralized management of hardware with MMB Agentless ServerView Agentless Service SVAS hardware monitoring LDAP function Lightweight Directory Access Protocol Remarks SVAS should be installed to monitor for any error in the PCI Express card 1 1 Since firmware monitor SAS RAID controller cards monit...

Page 40: ...nd FCoE connection Wake on LAN WOL Technologies that facilitate administration Centralized management of hardware with MMB Agentless ServerView Agentless Service SVAS hardware monitoring LDAP function Lightweight Directory Access Protocol Remarks SVAS should be installed to monitor for any error in the PCI Express card 1 1 Since firmware monitor SAS RAID controller cards monitoring SAS RAID contro...

Page 41: ...installed to monitor for any error in the PCI Express card 1 1 Since firmware monitor SAS RAID controller cards monitoring SAS RAID controller cards and HDD or SSD can be done without installing SVAS 1 4 1 CPU In PRIMEQUEST 2400E3 2800E3 2800B3 the Intel Xeon processor E7 v4 product family is mounted In PRIMEQUEST 2400E2 2800E2 2800B2 the Intel Xeon processor E7 v3 product family is mounted In PRI...

Page 42: ...et can have only same frequency 1 4 2 QuickPath Interconnect QPI The PRIMEQUEST 2000 series uses a high speed system bus called Intel Quick Path Interconnect QPI to communication between CPUs in a partition The resource can be increased by connecting peer CPUs by the QPI 1 4 3 Hyper Threading Technology Function PRIMEQUEST 2000 series supports the function of hyper threading technology In hyper th...

Page 43: ...the Memory Mirror function see 3 2 5 Memory Mirror in PRIMEQUEST 2000 Series Administration Manual CA92344 0537 1 4 5 Memory Sparing Function The PRIMEQUEST 2000 series is provided with a Memory Sparing function The Memory Sparing function prepares spare rank a rank means unit of the block of memory module to endure rank errors If predictive failure of a rank is detected copying the data of the ra...

Page 44: ...d to a SAS RAID controller card Activation of HDD SSD can be increased even when using a hardware RAID For details see Modular RAID Controller Modular SAS HBA MegaRAID SAS Software and MegaRAID SAS Device Driver Installation 1 4 8 PCI Hot Plug Function All PCI Express slots in the PCI_Box of the PRIMEQUEST 2000 series support the PCI hot plug function This function is a technology that enables ext...

Page 45: ...itions For details see 5 2 Physical Partitioning PPAR 1 4 13 Extended Partitioning The PRIMEQUEST 2400E3 2800E3 2400E2 2800E2 2400E 2800E supports the Extended Partitioning function The Extended Partitioning function is the function which divides the physical partition in units of CPU core Low cost high reliability and secure procedures are provided The features of this function are listed below T...

Page 46: ...ology VT c is the general term for the virtualization support functions VM Assist listed below IO AT CPU On board LAN controller I O Acceleration Technology IO AT IO AT indicates high speed I O technology which increases the speed and efficiency of processing data and interruption Intel QuickData Technology Direct Cache Access DCA Extended Message Signaled Interrupts MSI X Receive Side Coalescing ...

Page 47: ...bE The 10GbE interface of the 10GbE controller that is mounted on the IOU_10GbE externally outputs the data with a RJ 45 connector It is supported in 10G BASE T USER port MMB 0 and 1 port Port for connecting to an external terminal for operating and monitoring various MMB functions via the LAN It is supported in 1000BASE T REMCS port REMOTE port on MMB This is a LAN port for REMCS The port support...

Page 48: ...stem The following table shows whether the PXE boot is supported or not in each port TABLE 1 7 PXE boot support Component Port PXE Support Legacy EFI IPv4 IPv6 IPv4 IPv6 MMB User port Management LAN 1000Base T REMCS port 100Base TX CE port 100Base TX IOU_1GbE IOU_10GbE LAN port IOU_1GbE 1000Base T Supported Supported Supported LAN port IOU_10GbE 10GBase T Supported Supported Supported PCI Express ...

Page 49: ...t CNA Supported Supported Supported Except for CNA PCI_Box PCI Express slot CNA Supported Supported Supported Except for CNA TABLE 1 9 iSCSI connections Component Port iSCSI connection Legacy EFI IPv4 IPv6 IPv4 IPv6 MMB User port Management LAN 1000Base T REMCS port 100Base TX CE port 100Base TX IOU_1GbE IOU_10GbE Operation port LAN port IOU_1GbE 1000Base T Supported Supported Supported Supported ...

Page 50: ... port IOU_1GbE 1000Base T Operation port LAN port IOU_10GbE 10G Base T PCI Express slot CNA Supported Except for CNA PCI_Box PCI Express slot CNA Supported Except for CNA TABLE 1 11 FCoE connections Component Port FCoE connection Legacy EFI IPv4 IPv6 IPv4 IPv6 MMB User port Management LAN 1000Base T REMCS port 100Base TX CE port 100Base TX IOU_1GbE IOU_10GbE Operation port LAN port IOU_1GbE 1000Ba...

Page 51: ...2 2800B to improve quality of PRIMEQUEST systems using Red Hat Enterprise Linux 1 The memory dump can be acquired by executing sadump when error occurs irrespective of the status of the RHEL that is operating in the PRIMEQUEST 2000 series Then investigation of the cause of error and support becomes possible thereby receiving a high degree of support 1 sadump is not supported on SUSE Linux Enterpri...

Page 52: ...er consumption Optimal Fan Control Cooling function below Determines the rpm of the fan considering both the Ambient and the Component temperature of the place where the system is set and configuration pattern of the system There is the concept of cooling group in a cabinet which controls fan rotational speed for each group For details on cooling see 2 16 Fan Cooling mechanism 1 4 30 Air Flow Moni...

Page 53: ...ng is a function that reduces the use of agent software on OS and monitors the server by the hardware It is necessary to install the SVAS if PCI Express card should be monitored 1 1 SVAS does not monitor SAS RAID controller card Since BMC firmware and MMB firmware monitor SAS RAID controller cards monitoring SAS RAID controller cards can be done without installing SVAS 1 4 35 LDAP function Lightwe...

Page 54: ...nterface between the software in the higher level layers MMB firmware MMB firmware manages entirely all models of PRIMEQUEST 2000 series Included functions are System management function Hardware monitoring Power control system initialization Mirror mode setup and partition configuration control Web UI function for system management User authority management Time synchronization Scheduled power on...

Page 55: ...s card 1 When an error is detected it is reported through MMB 1 Since firmware monitor SAS RAID controller cards monitoring SAS RAID controller cards can be done without installing SVAS Note If SV Agent is installed it is not possible to install SVAS ServerView Suite SVS The SVS provides following functions all of them are bundled as standard products ServerView Installation Manager SVIM ServerVie...

Page 56: ...iver selection to the extent that even users without expertise can implement a setup easily and securely in a short time Setting up using the SVIM results in a stable operation early at the beginning of an operation FIGURE 1 9 SVIM setup flow Item Description Automatic HDD RAID configuration You can configure RAID using configuration tool called WebBIOS This tool is started after power on and star...

Page 57: ...application SVIM applies an emergency level hot fix for the operating system This prevents the occurrence of known faults and promotes stable operation ServerView Operations Manager SVOM SVOM identifies hardware faulty parts displays diagnosis on the console and sends e mail to the administrator to support early recovery and stable operation ServerView Agent SV Agent SV Agent monitors the status o...

Page 58: ...on virtual software might not be assured depending on the middleware or operation pattern 1 5 5 Clustering Red Hat Enterprise Linux RHEL supports clustering with PRIMECLUSTER Fujitsu middleware Windows Server 2012 R2 Windows Server 2012 and Windows Server 2008 R2 support the clustering with Failover Cluster OS standard function Using clustering can improve the availability of the entire system Clu...

Page 59: ...Per system 3 4 3 3 FANU 0 FANU 5 etc Possible by option FANM Per FANU 2 2 2 2 FANM 0 FANM 1 Possible as standard SB Per system 2 2 4 4 SB 0 SB 3 etc Possible by option CPU Per SB 2 2 2 2 CPU 0 CPU 1 No DIMM Per SB Except Mezzanine 24 24 24 24 DIMM 0A0 DIMM 1B5 etc Possible by option Mezzanine Per SB 2 2 2 2 Mezz 0 Mezz 1 No DIMM Per Mezzanine 12 12 12 12 DIMM 0C0 DIMM 1D5 etc Possible by option SA...

Page 60: ...n 3 FH 2 2 2 2 DU Per system 2 2 2 2 DU 0 DU 1 Possible by software RAID SAS RAID controller card 2 2 2 2 PCI Slot Possible by software RAID FBU 2 2 2 2 FBU HDD SSD 4 4 4 4 HDD 0 HDD 3 etc Possible by option MMB Per system 2 2 2 1 MMB 0 MMB 1 Possible by option OPL Per system 1 1 1 1 OPL No MP Per system 1 1 1 1 MP No 1 In the PRIMEQUEST 2400E3 2800E3 2800B3 2400E2 2800E2 2800B2 2400E 2800E 2800B ...

Page 61: ...ation 2 2 Base cabinet 38 CA92344 0534 07 2 2 Base cabinet An overview of the PRIMEQUEST 2000 series device is shown below FIGURE 2 1 PRIMEQUEST 2400E3 2800E3 2400E2 2800E2 front view FIGURE 2 2 PRIMEQUEST 2400E 2800E front view ...

Page 62: ... cabinet 39 CA92344 0534 07 FIGURE 2 3 PRIMEQUEST 2400E3 2800E3 2400E2 2800E2 2400E 2800E rear view FIGURE 2 4 PRIMEQUEST 2400E3 2800E3 2400E2 2800E2 2400E 2800E top view FIGURE 2 5 PRIMEQUEST 2400E3 2800E3 2400E2 2800E2 2400E 2800E right view ...

Page 63: ...CHAPTER 2 Hardware Configuration 2 2 Base cabinet 40 CA92344 0534 07 FIGURE 2 6 PRIMEQUEST 2400E3 2800E3 2400E2 2800E2 2400E 2800E perspective view FIGURE 2 7 PRIMEQUEST 2800B3 2800B2 front view ...

Page 64: ...CHAPTER 2 Hardware Configuration 2 2 Base cabinet 41 CA92344 0534 07 FIGURE 2 8 PRIMEQUEST 2800B front view FIGURE 2 9 PRIMEQUEST 2800B3 2800B2 2800B rear view ...

Page 65: ...dware Configuration 2 2 Base cabinet 42 CA92344 0534 07 FIGURE 2 10 PRIMEQUEST 2800B3 2800B2 2800B top view FIGURE 2 11 PRIMEQUEST 2800B3 2800B2 2800B right view FIGURE 2 12 PRIMEQUEST 2800B3 2800B2 perspective view ...

Page 66: ...E3 2800E3 2800B3 E7 8893v4 4 3 2 GHz 60 MB 9 6 GT s Available Available Available E7 8891v4 10 2 8 GHz 60 MB 9 6 GT s Available Available Available E7 8890v4 24 2 2 GHz 60 MB 9 6 GT s Available Available Available E7 8880v4 22 2 2 GHz 55 MB 9 6 GT s Available Available Available E7 8870v4 20 2 1 GHz 50 MB 9 6 GT s Available Available Available E7 8867v4 18 2 4 GHz 45 MB 9 6 GT s Available Availabl...

Page 67: ...vailable Available E7 8850 v2 12 2 3 GHz 24 0 MB 7 2 GT s Not available Available Available E7 8857 v2 12 3 0 GHz 30 0 MB 8 0 GT s Not available Available Available E7 8893 v2 6 3 4 GHz 37 5 MB 8 0 GT s Available Available Available E7 4890 v2 15 2 8 GHz 37 5 MB 8 0 GT s Available Not available Not available E7 4880 v2 15 2 5 GHz 37 5 MB 8 0 GT s Available Not available Not available E7 4870 v2 15...

Page 68: ...s 4 DIMMs or 8 DIMMs 1 Full mirror Partial mirror 4 DIMMs 8 DIMMs or 16 DIMMs 1 Address range mirror 8 DIMMs or 16 DIMMs 1 Spare 6 DIMMs 12 DIMMs or 24 DIMMs 1 RAS SDDC Bank DDDC Error correction ECC Port USB External 4 USB 1 1 2 0 connector type USB Type A VGA External 1 D sub 15 pin LED Power Alarm Location External dimension mm excluding protrusions Width 90 5 x depth 528 1 x height 430 8 Weigh...

Page 69: ... v2 product family Socket 2 System Interconnect QPI speed 8 0 GT s 7 2 GT s 6 4 GT s QPI bandwidth 32 GB s per port bidirectional at 8 0 GT s Memory DIMM type DDR3 RDIMM LRDIMM LV RDIMM LV LRDIMM Slot 48 Maximum capacity 3072 GB for 64 GB DIMM 2CPU Expansion unit Normal Performance 2 DIMMs 4 DIMMs or 8 DIMMs 1 Full mirror Partial mirror 4 DIMMs 8 DIMMs or 16 DIMMs 1 Spare 6 DIMMs 12 DIMMs or 24 DI...

Page 70: ...CHAPTER 2 Hardware Configuration 2 5 SB System board 47 CA92344 0534 07 FIGURE 2 14 SB External view 2400E3 2800E3 2400E2 2800E2 ...

Page 71: ...CHAPTER 2 Hardware Configuration 2 5 SB System board 48 CA92344 0534 07 FIGURE 2 15 SB External view 2800B3 2800B2 ...

Page 72: ...CHAPTER 2 Hardware Configuration 2 5 SB System board 49 CA92344 0534 07 FIGURE 2 16 SB External view 2400E 2800E ...

Page 73: ...ing up the SB is shown follows CPU Three system buses called Intel QuickPath Interconnect QPI are output from each CPU Large scale configuration SMP with up to 8 CPUs can be made by connecting to other CPUs A memory controller is also mounted in CPU and four SMI2 interfaces are output Memory Buffer MB In PRIMEQUEST 2400E3 2800E3 2800B3 2400E2 2800E2 2800B2 the MB is a converter chip that is connec...

Page 74: ...s controller There are four USB ports in the front as external connectors and one port as an internal connector The USB outputs four ports as external connectors in the front Keyboard and mouse can be connected in the external connector BMC BMC is an SB management LSI It is connected to the LPC bus It communicates with the MMB via the BMC built in NIC and exchanges information of the PECI bus inte...

Page 75: ...TABLE 2 8 Memory Scale up Board specifications Item Specifications 2400E3 2400E2 Memory DIMM type DDR4 RDIMM LRDIMM LV RDIMM LV LRDIMM Slot 48 Maximum capacity 6144GB for 128 GBDIMM 2CPU 3072 GB for 64 GB DIMM 2CPU Expansion unit Normal Performance 2 DIMMs 4 DIMMs or 8 DIMMs 1 Full mirror Partial mirror 4 DIMMs 8 DIMMs or 16 DIMMs 1 Address range mirror 2 8 DIMMs or 16 DIMMs 1 Spare 6 DIMMs 12 DIM...

Page 76: ...mory Buffers and 12 DIMM slots are mounted Two Memory Mezzanines are mounted for each Memory Scale up Board BMC BMC is an SB management LSI It is connected to the LPC bus It communicates with the MMB via the BMC built in NIC and exchanges information of the PECI bus interface to the BIOS and the GPIO control SPI Flash SPI Flash is the abbreviation of the Serial Peripheral Interface Flash It is a f...

Page 77: ... is duplicated when two MMBs are mounted in PRIMEQUEST 2400E3 2800E3 2400E2 2800E2 2400E 2800E 2 7 1 MMB specifications The MMB specification is listed in the table below TABLE 2 9 MMB specifications Item Specifications Serial interface COM port DB9 1 port For initial setup LAN interface USER port 0 1 RJ45 100 Mbps 1 Gbps 2 ports REMCS port RJ45 100 Mbps 1 port CE port RJ45 100 Mbps 1 port Hot plu...

Page 78: ... USER port 0 1 port of the MMB These LAN ports are used to connect an MMB operation terminal for a user to the MMB The user can use a Web browser from the MMB operation terminal to communicate with the MMB firmware and operate and manage the PRIMEQUEST 2000 series USER port can be duplicated This port is for 1000Base T support REMCS port MMB REMOTE port REMCS port is used for a connection Internet...

Page 79: ...ontroller IOU_1GbE GbE LAN Controller IOU_10GbE LAN Controller Intel Powerville HI350AM2 Intel Twinville JLX540AT2 Standards IEEE802 3i 10BASE T IEEE802 1p IEEE802 3u 100BASE TX IEEE802 1q VLAN IEEE802 3ab 1000BASE T IEEE802 3ad LACP IEEE802 1q VLAN IEEE802 3 2005 flow control support IEEE802 3x Flow Control IEEE802 3ad LACP IEEE802 3az Power Management and Saving IEEE802 1as Time Sync IEEE1588 Pr...

Page 80: ...nnection are then connected by a dedicated cable Up to two FBUs can be installed at PCI Express slot 0 for IOU_1GbE Note If a FBU is installed a PCI Express card cannot be installed at PCI Express slot 0 A FBU cannot be installed into IOU_10GbE The overview of IOU_1GbE and IOU_10GbE are shown below FIGURE 2 21 External view of IOU_1GbE No Description 1 Top view 2 Front view 3 Front lateral view 4 ...

Page 81: ... a unit used to mount the HDD SSD One or two SAS RAID controller cards can be mounted in the DU In total there are four 2 5 inch disk slots in the DU The DU is connected to the IOU by the PCI Express Gen2 4Lane interface Connections of the IOU to the DU are listed in the table below TABLE 2 12 Connection of IOU with DU Connection source Destination Connection destination HDD For two HDD per SAS RA...

Page 82: ...RAID controller card HDD slot 2 5 inch SAS SATA HDD slot 4 HDD hot plug Supported 1 Enclosure Management SGPIO Present monitoring and Fault LED control by SGPIO controller each HDD Supported RAID level 0 1 5 6 10 1E 2 LED Power Attention Access LED for each HDD Alarm LED each HDD Dimension mm except protrusions Width 45 x Depth 526 x Height 215 Weight kg without HDD SSD 2 9 kg 1 Hot plug of HDD is...

Page 83: ...ction describes the internal HDD and internal SSD solid state drive supported by the PRIMEQUEST 2000 series Component that can include internal HDD SSD in the PRIMEQUEST 2000 series is as below HDD bays in the SB Except for PRIMEQUEST 2800B3 2800B2 2800B DU For number of slot built in SB and DU see TABLE 1 3 Hardware specifications The specifications and capacity of the components mounted in the i...

Page 84: ...DU 4 Maximum capacity of supported HDD SSD HDD 1 2 TB SSD 1 6 TB 1 Available HW RAID levels differ depending on the number of SAS RAID controller cards HDDs mounted 2 HW RAID being RAID0 when using the SW RAID GDS is a condition 2 10 1 Internal HDD Hard disk drive The HDD capacity in the maximum configuration 1 and the maximum LUN capacity in a RAID configuration are listed in the table below 1 In...

Page 85: ...SSD capacity in maximum configuration and the maximum LUN capacity in a RAID configuration RAID configuration PRIMEQUEST Maximum LUN 1 2400E3 2400E2 2400E 2800E3 2800E2 2800E 2800B3 2800B2 2800B 1 6 TB SSD SAS non RAID 25 6 TB 38 4 TB 12 8 TB 1 6 TB SAS RAID RAID0 25 6 TB 38 4 TB 12 8 TB 6 4 TB x4 SAS RAID RAID1 12 8 TB 19 2 TB 6 4 TB 1 6 TB 1 1 SAS RAID RAID5 19 2 TB 28 8 TB 9 6 TB 4 8 TB 3 1 SAS...

Page 86: ...e Configuration 2 11 OPL Operator panel 63 CA92344 0534 07 An overview of the OPL is shown below FIGURE 2 25 External view of OPL No Description 1 Top view 2 Front view 3 Front side perspective view 4 Right lateral view ...

Page 87: ...n in the main unit side A PCNC is mounted on the PCI Express slot of the IOU and a cable is connected to the connector on the card 2 12 1 PCI_Box specification The specification of the PCI_Box is listed in the table below TABLE 2 20 PCI_Box Specification Item Specifications PCI Express slot 12 8 lane Gen3 8GbpS PCI Express interface 2 LED Power Alarm Location Hot plug Hot plug for PCI_Boxes itself...

Page 88: ...CHAPTER 2 Hardware Configuration 2 12 PCI_Box 65 CA92344 0534 07 FIGURE 2 26 PCI_Box conceptual diagram ...

Page 89: ...7 2 12 3 PCI_Box external view The following figures show external views of the PCI_Box cabinet FIGURE 2 27 Orthographic view of the PCI_Box cabinet No Description 1 Top view 2 Front view 3 Right view 4 Rear view FIGURE 2 28 Perspective views of the PCI_Box cabinet ...

Page 90: ...ble as standard PEXU 1 PCI _Box PEXU No PCIB 1 PEXU PCIB No LNKC 2 PCIB LNKC 0 LNKC 1 No PCI Express slot 12 PCIB PCIC 0 PCIC 11 etc Possible by option 2 12 6 PCI_Box connection pattern The PCI_Box is connected to the PCNC on the IOU One port on the PCI_Box is connected to one PCNC on the IOU by three PCI_Box connection cables Two PCI Express cables and one PCI_Box control cable Number of connecta...

Page 91: ...details on the connection conditions of the PCI_Box see 2 12 7 PCI _Box connection conditions FIGURE 2 30 PCI_Box connection diagram maximum configuration for mounted four IOU_1GbEs FIGURE 2 31 PCI_Box connection diagram maximum configuration for mounted four IOU_10GbEs ...

Page 92: ...inet cannot be connected to the same PCI_Box PCI_Box sharing Connection examples are shown below Straight connections permitted Crossover connections permitted Connection to different PCI_Boxes pattern 1 permitted Connection to different PCI_Boxes pattern 2 permitted Connection from IOU_1GbE and IOU_10GbE permitted Sharing of one PCI_Box by different PRIMEQUEST series cabinet cabinet not permitted...

Page 93: ...tion 2 12 PCI_Box 70 CA92344 0534 07 FIGURE 2 34 Connection to different PCI_Boxes pattern 1 permitted FIGURE 2 35 Connection to different PCI_Boxes pattern 2 permitted FIGURE 2 36 Connection from IOU_1GbE and IOU_10GbE permitted ...

Page 94: ...E3 2800E2 2800E 2800B3 2800B2 2800B Number of PCI Express slots Short 56 1 56 1 16 1 Except PCI Express slots where the PCNC is mounted The number of PCI Bus assigned per a slot can be set by BIOS menu Default is 1 If a PCI Express card with bridge function is mounted it is required to assign two or more PCI Buses per a slot 2 13 1 PCI Express slot IOU specifications There are two kinds of IOU in ...

Page 95: ...d for PCI_Box 2 14 Middle Plane MP The MP is an intermediate metal board for connecting SB Memory Scale up Board and IOUs The MP has a structure in which SBs Memory Scale up Boards and IOUs are linked from both sides The MP is used only for connections between boards It has no power supply or devices 2 15 Power Supply Unit PSU PSU is a power supply unit to convert the AC input to DC 12V In the PRI...

Page 96: ...cabinet For the configuration of the PSU see 4 5 1 PSU Configuration 2 15 1 PSU_P specifications The specifications of PSU_P are listed in the table below TABLE 2 26 PSU_P Specifications Item Specifications Input voltage 1 φ AC 100 V 120V 1 φAC200 V 240 V Output voltage DC12V Output power AC100 V 1 1165 W AC200 V 2685 W External dimensions mm Excluding protrusions Width 137 Depth 255 Height 128 We...

Page 97: ...Manual CA92344 0536 2 15 5 AC cable specifications For details on the AC cable specifications see PRIMEQUEST 2000 Series Installation Manual CA92344 0536 2 15 6 Mounting conditions when using 100V power supply For details on the mounting conditions when using 100 V power supply see Appendix G Component Mounting Conditions of the PRIMEQUEST 2000 Series Administration Manual CA92344 0539 2 16 Fan Co...

Page 98: ...E2 2800B2 supports the following operating systems Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Red Hat Enterprise Linux 7 for Intel64 1 Red Hat Enterprise Linux 6 for Intel64 1 2 VMware vSphere 6 3 VMware vSphere 5 3 Novell SUSE LINUX Enterprise Server 12 Novell SUSE LINUX Ente...

Page 99: ...pported Supported Supported Supported Supported 6 HBA blockage function Stops access to abnormal nodes Not supported Not supported Not supported Supported Not supported 7 ServerView Installation Manager SVIM Supports setup work Supported Supported Supported Supported Supported 8 ServerView Mission Critical Option SVmco Necessary when linking clusters Not supported Not supported Not supported Suppo...

Page 100: ...ce firmware For details on the feature of each firmware see 1 5 1 Firmware 3 6 Operations Management Software PRIMEQUEST 2000 series is linked to the operation management products of Fujitsu Limited Enterprise Server Management ESM 1 It provides a function for linking with the major operations management software IBM Tivoli HP SIM of other companies 1 Example ServerView Resource Orchestrator ...

Page 101: ... Basic Architecture The following figure shows the basic architecture of the PRIMEQUEST 2000 series for hardware system management FIGURE 4 1 Basic architecture 4 2 Management with MMB This section provides an overview of the MMB management function and its operating environment 4 2 1 MMB functions The MMB firmware runs on a processor on the MMB and enables the management functions of an entire sy...

Page 102: ... BMC firmware and with SVAS or SVS and regularly monitoring the entire system The MMB firmware provides an interface to the higher level operations management via SNMP and IPMI MMB firmware controls the server by coordinating with BIOS firmware and BMC firmware 4 2 3 User account management of MMB There are two ways to manage user account of MMB in PRIMEQUEST 2000 series Local user management Loca...

Page 103: ...cribes the security in the MMB operating environment SSL support The MMB encrypts Web and telnet access using SSL Secure Sockets Layer It creates secret keys and electronic certificates Remarks The MMB is provided with interfaces such as telnet and the Web UI and also manages their system accounts The MMB can be configured redundantly so that the information specified for the Active side can be pa...

Page 104: ...e status of the detected component The MMB collects all logs of such event log of a failure or error where processing could continue by using an alternate component or disconnecting the faulty component To reduce the number of logs or messages displayed all logs and messages can be filtered before display The conditions for reporting detected abnormal states can also be specified Hardware failure ...

Page 105: ...configuration can show each incorporated SB Memory Scale up Board and IOU and their components in detail The partition can be changed by modifying the combination of the SB Memory Scale up Board and IOU in the same way as they were specified 4 3 REMCS automatic notification function The REMCS Agent automatically detects the hardware fault prediction information and reports the information to the O...

Page 106: ...upply Monitoring and Control This section describes power supply monitoring and the system operations when there is a failure 4 5 1 PSU Configuration To design PRIMEQUEST 2000 series you need to identify quantity of fan and PSU because relevant maximum numbers different by PRIMEQUEST models The number of required PSUs and the dual power feed also differs in the100 V power reception and the 200 V p...

Page 107: ... up Board you must install PSU according to TABLE 4 3 PSU mounting location PRIMEQUEST 2800E3 2800B3 2800E2 2800B2 2800E 2800B TABLE 4 3 PSU mounting location PRIMEQUEST 2800E3 2800B3 2800E2 2800B2 2800E 2800B Input voltage Power feeding method PSU Configuration Required number Mounting location PSU FANU PSU FANU 200 V Single power feed 3 0 3 3 0 3 1 2 4 5 3 1 4 2 0 3 1 4 2 5 Dual power feed 3 x 2...

Page 108: ...tions from a remote terminal using the MMB Web UI Power supply operation by WOL function is also available Both IOU_1GbE and IOU_10GbE support WOL Remarks The support for WOL depends on the OS Refer to each OS manual for details 4 5 6 UPS Uninterruptible Power System UPS is an external battery unit With a UPS connected the device can be prepared for a power failure or sudden power supply fluctuati...

Page 109: ...s with the MMB time 4 6 2 NTP client In PRIMEQUEST 2000 series the MMB becomes an NTP client to synchronize the time with an external NTP server When NTP servers in an external network are not connected to the PRIMEQUEST 2000 series it is recommended to use an NTP server device that uses an external clock As shown in the following figure the MMB can access another NTP server and synchronize the ti...

Page 110: ... the threshold for a given period occur proactive monitoring detects the component causing the errors and reports it to the MMB When an event report on an exceeded threshold value is generated a prompt plan to stop and disconnect the component is requested Proactive monitoring is performed by SVS BIOS and MMB firmware SVS is server management software that can perform integration management of the...

Page 111: ... If e mail notification is specified the MMB sends e mail REMCS notification When REMCS connection is specified the MMB sends a notification System Event Log output The transmission destination for mail notification and REMCS notification has to be set in the Web UI of the MMB For the details on REMCS see PRIMEQUEST 2000 series REMCS Service Manual CA92344 0542 4 8 Video Redirection The video redi...

Page 112: ... memory dump could not be acquired during the early stage of booting up and just before shut down FIGURE 4 9 Sadump conceptual diagram sadump is activated by selecting sadump in Partition Power Control of the MMB Web UI when error occurs in the OS 4 11 1 sadump firmware The sadump is a dump acquiring firmware of the PRIMEQUEST 2000 series except for PRIMEQUEST 2800B3 2800B2 2800B It provides a fun...

Page 113: ...Function Windows In Windows the dump can be acquired using the standard functions of the OS Before acquiring a dump it is necessary to ensure the disk region in advance For details of settings for acquiring the dump see 10 4 3 Setting up the dump environment Windows of the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 ...

Page 114: ...ning a high degree of failure isolation In the PRIMEQUEST 2000 series the partition configuration can be changed with a static configuration control function The function for changing the configuration of each partition is triggered by a power off power on or reboot The maximum number of PPAR partitions is listed in the table below TABLE 5 1 Maximum number of partitions for each model PPAR Model M...

Page 115: ...R 5 Partitioning 5 2 Physical Partitioning PPAR 92 CA92344 0534 07 FIGURE 5 1 Conceptual diagram of the partitioning PRIMEQUEST 2400E3 2400E2 FIGURE 5 2 Conceptual diagram of the partitioning PRIMEQUEST 2400E ...

Page 116: ...tition granularity The partition granularity of the Memory Scale up Board is one physical Memory Scale up Board IOU partition granularity The partition granularity of the IOU is one physical IOU DU partition granularity The partition granularity of the DU is a physical DU divided in two Since four HDDs can be installed in each physical DU the partition granularity of the DU is two HDDs TABLE 5 3 R...

Page 117: ... that have been divided by partitioning Those partitions can be used independently as servers 5 3 1 Partition granularity of the Extended Partitioning The Extended Partitioning can effectively use the server resources with the fine granularity of partitions The following table lists the partition granularity of the components that make up a partition TABLE 5 5 Partition granularity of each compone...

Page 118: ...g to same Zone is allowed Zoning function can be set to each EP by MMB Web UI VLAN tag VLAN function is the function that separates traffics within a divided zone VLAN tag VLAN function can be set by OS on the EP 5 5 Memory Scale up Board Memory Scale up Board is the board for expanding memory without increasing CPU Memory Scale up Board is supported in only PRIMEQUEST 2400E3 2400E2 Up to three Me...

Page 119: ...ction provides notes on the partition configuration SB that operates a partition must use the CPUs and memory Memory Scale up Board that operates a partition must use the memory Memory Scale up Board cannot be set to Home SB If you include Memory Scale up Board into a partition at least one SB must be included in the partition For the details on the partition configuration see 3 1 Partition config...

Page 120: ...ing a smaller number than the Home SB is added using the DR function and when the Home SB is not necessarily the SB of the smallest physical number To find out which SB is the Home SB please check with the MMB Web UI The setting of the Home SB during an SB degradation Reserved SB operation is as follows When the Home SB is degraded the SB with the smallest number among the remaining SBs becomes th...

Page 121: ...CHAPTER 5 Partitioning 5 11 Home SB 98 CA92344 0534 07 Note Hot replacement and hot remove of Home SB cannot be performed by Dynamic Reconfiguration Memory Scale up Board cannot be set to Home SB ...

Page 122: ...n a cabinet or in external RAID devices by using software mirroring such as PRIMECLUSTER GDS 3 The redundancy between multiple redundant volumes The redundancy of inter volume is achieved by mirroring multiple disks with RAID configuration except for RAID0 configuration in external RAID devices by using software mirroring such as PRIMECLUSTER GDS Below table shows procedures of disk redundancy TAB...

Page 123: ...s to the configuration of the operation system Configuration of a redundant network or and network interface requires at least two network interfaces and an optional software for switching these interfaces The operation LAN redundancy supported by the PRIMEQUEST 2000 series is as follows Duplication of a transmission path between servers high speed switching method Depending on the duplex network ...

Page 124: ...s to which hot maintenance can be applied For details on each component see Chapter 3 Component configuration and replacement expansion removal of the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 PSU A PSU alone can be replaced while the system continues running Replacement of a PSU in a non redundant configuration requires the system to be stopped Fan A fan alone can be replaced whil...

Page 125: ...vely provide the functions for managing the server system The following diagram lists the overall configuration of the operations management tools provided in the PRIMEQUEST 2000 series FIGURE 8 1 Overall configuration diagram of the operations management tools The MMB Firmware controls the entire server system in linkage with the SVS and other firmware BIOS or BMC Firmware SVS links with the MMB ...

Page 126: ... on the video redirection see 1 6 2 Remote operation BMC in the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 8 4 Console Redirection The console redirection function directs the serial output from a partition to a terminal via a LAN The console output to the COM port on a partition is redirected by this function to a terminal connected to a LAN through the console redirection In addit...

Page 127: ...SuSE Red Hat VMware ServerView database Linux Manual for installing the Manager SVOM Agent functions of SVS in a Linux OS environment and VMware environment this procedure is not necessary when installing the Manager function Agent function using the SVIM ServerView Suite ServerView Operations Manager V4 92 Quick Installation Linux Quick guide for installing the agent function of the SVS in a Linu...

Page 128: ...rverView Update Manager Express Installing BIOS and Firmware via ASPs Installing Drivers and additional Software via PSPs Manual describing the function that applies the updates of firmware from bootable media SVDM Deploy ServerView Suite ServerView Deployment Manager Manual that describes the provisioning function for servers installation of OS applications etc SVmco ServerView Mission Critical O...

Page 129: ...gement of system information and during maintenance Below settings are required for maintenance by the field engineers Video redirection and virtual media are available For details on this setting see 1 3 6 Console Redirection Setup window in PRIMEQUEST 2000 series Tool Reference CA92344 0539 Telnet or SSH is available For details on this setting see 1 5 4 Network Protocols window in PRIMEQUEST 20...

Page 130: ...layed on the window Click the Filter button System Event Log Filtering Condition window for entering the filtering conditions appears Enter the conditions in the System Event Log Filtering Condition screen and click the Apply button The browser returns to the System Event Log window and the events that satisfy the specified criteria are displayed Displaying the details of events displayed on the w...

Page 131: ... and Connection 108 CA92344 0534 07 Hardware Installation and CHAPTER 10 Connection For details on the installation rack mounting and connection in the PRIMEQUEST 2000 series see PRIMEQUEST 2000 Series Installation Manual CA92344 0536 ...

Page 132: ...tions 109 CA92344 0534 07 Appendix A Component Mounting Locations For details on the component mounting locations see Appendix B Physical mounting position and port number in the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 ...

Page 133: ...on the correspondence between the physical location and the BUS number of the built in I O and between the mounting location and slot number in the PRIMEQUEST 2000 series see Appendix D Physical Locations and BUS Numbers of Built in I Os and PCI Slot Mounting Locations and Slot Numbers in the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 ...

Page 134: ...LEDs 111 CA92344 0534 07 Appendix C Status checks with LEDs For details on the status check with LEDs in the PRIMEQUEST 2000 series see Appendix F Status Check by LED in the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 ...

Page 135: ...ng Conditions 112 CA92344 0534 07 Appendix D Component Mounting Conditions For details on component mounting conditions see Appendix G Component Mounting Conditions in the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 ...

Page 136: ...E Cable Specifications 113 CA92344 0534 07 Appendix E Cable Specifications For details on cable specifications see Chapter 2 Connection Information in the PRIMEQUEST 2000 series Installation Manual CA92344 0535 ...

Page 137: ... 07 Appendix F Tree Structure of the MIB provided with the PRIMEQUEST 2000 series For details on the MIB tree structure provided in the PRIMEQUEST 2000 series see Appendix H MIB Tree Structure provided in the PRIMEQUEST 2000 series in the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 ...

Page 138: ...EST 2000 series G 1 Linkage with Systemwalker Centric Manager For details on the Linkage with Systemwalker Centric Manager see Appendix J Linkage with Systemwalker Centric Manager in the PRIMEQUEST 2000 Series Administration Manual CA92344 0537 G 2 Remote Customer Support System REMCS For details on Remote Customer Support System REMCS see PRIMEQUEST 2000 series REMCS Service Manual CA92344 0542 ...

Page 139: ... Y Y Y Y Y Y Y Y Y Y Y Y C Dynamic Reconfiguration D Reserved SB Y N Y Y Y Y Y Y Y Y Y N N Y E Extended Partitioning F Extended Socket G Power Saving Y Y Y Y Y Y Y Y Y Y Y Y Y Y H Segment Mode Y Y Y Y N Y Y Y Y Y Y Y Y Y I Bus Mode Y Y Y Y N Y Y Y Y Y Y Y Y Y J Memory Scale up Board K Secure Boot Y Y Y Y Y Y Y Y Y Y Y Y Y Y L Memory Operation Mode Normal Y Y Y Y Y Y Y N N N N Y Y Y M Memory Operat...

Page 140: ...Reconfiguration D Reserved SB Y N Y Y Y Y Y Y Y Y N N Y Y E Extended Partitioning F Extended Socket G Power Saving Y Y Y Y Y Y Y Y Y Y Y Y Y Y H Segment Mode Y Y Y Y N Y Y Y Y Y Y Y Y Y I Bus Mode Y Y Y Y N Y Y Y Y Y Y Y Y Y J Memory Scale up Board K Secure Boot L Memory Operation Mode Normal Y Y Y Y Y Y N N N N Y Y Y Y M Memory Operation Mode Performance Y Y Y Y Y Y N N N N Y Y Y Y N Full Memory ...

Page 141: ...Y Y Y Y C Dynamic Reconfiguration D Reserved SB Y N Y Y Y Y Y Y Y Y N N Y Y E Extended Partitioning F Extended Socket G Power Saving Y Y Y Y Y Y Y Y Y Y Y Y Y Y H Segment Mode Y Y Y Y N Y Y Y Y Y Y Y Y Y I Bus Mode Y Y Y Y N Y Y Y Y Y Y Y Y Y J Memory Scale up Board K Secure Boot L Memory Operation Mode Normal Y Y Y Y Y Y N N N N Y Y Y Y M Memory Operation Mode Performance Y Y Y Y Y Y N N N N Y Y ...

Page 142: ...eserved SB Y N Y Y Y Y Y Y Y Y Y Y Y E Extended Partitioning F Extended Socket G Power Saving Y Y Y Y Y Y Y Y Y Y Y Y Y H Segment Mode 1 Y Y Y Y N Y Y Y Y Y Y Y Y I Bus Mode Y Y Y Y N Y Y Y Y Y Y Y Y J Memory Scale up Board K Secure Boot L Memory Operation Mode Normal Y Y Y Y Y Y N N N N N Y Y M Memory Operation Mode Performance Y Y Y Y Y Y N N N N N Y Y N Full Memory Mirror Y Y Y Y Y Y N N N N N ...

Page 143: ...ation D Reserved SB Y N Y Y Y Y Y Y Y Y Y Y E Extended Partitioning F Extended Socket G Power Saving Y Y Y Y Y Y Y Y Y Y Y Y H Segment Mode 1 I Bus Mode Y Y Y Y Y Y Y Y Y Y Y Y J Memory Scale up Board K Secure Boot L Memory Operation Mode Normal Y Y Y Y Y N N N N N Y Y M Memory Operation Mode Performance Y Y Y Y Y N N N N N Y Y N Full Memory Mirror Y Y Y Y Y N N N N N Y Y O Partial Memory Mirror Y...

Page 144: ... N Y Y Y Y Y N Y Y Y Y Y Y Y N Y Y F Extended Socket Y Y N Y Y Y Y Y N Y Y Y Y Y Y Y N Y Y G Power Saving Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y H Segment Mode Y Y Y Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y I Bus Mode Y Y N Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y J Memory Scale up Board Y Y N N N N Y Y Y Y Y Y Y Y Y Y Y Y Y K Secure Boot Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y L Memory Operation Mode Normal Y Y Y Y Y...

Page 145: ...Reserved SB Y N Y Y Y Y Y Y N Y Y Y Y Y Y Y Y E Extended Partitioning Y Y N Y Y Y Y Y N Y Y Y Y Y Y Y Y F Extended Socket Y Y N Y Y Y Y Y N Y Y Y Y Y Y Y Y G Power Saving Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y H Segment Mode Y Y Y Y Y Y Y N Y Y Y Y Y Y Y Y Y I Bus Mode Y Y N Y Y Y Y N Y Y Y Y Y Y Y Y Y J Memory Scale up Board Y Y N N N N Y Y Y Y Y Y Y Y Y Y Y K Secure Boot L Memory Operation Mode Norma...

Page 146: ... Y Y N Y Y D Reserved SB Y N Y Y Y Y Y Y Y Y Y Y Y N Y Y E Extended Partitioning F Extended Socket G Power Saving Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y H Segment Mode Y Y Y Y Y N Y Y Y Y Y Y Y Y Y Y I Bus Mode Y Y N Y Y N Y Y Y Y Y Y Y Y Y Y J Memory Scale up Board K Secure Boot Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y L Memory Operation Mode Normal Y Y Y Y Y Y Y Y N N N N N Y Y Y M Memory Operation Mode Perform...

Page 147: ...Y Y Y Y Y Y B Fixed I O N Y N Y Y Y Y Y Y Y Y Y Y Y C Dynamic Reconfiguration Y Y Y Y Y N Y N Y Y Y Y Y Y D Reserved SB Y N Y Y Y Y Y Y Y Y Y Y Y Y E Extended Partitioning F Extended Socket G Power Saving Y Y Y Y Y Y Y Y Y Y Y Y Y Y H Segment Mode Y Y Y Y Y N Y Y Y Y Y Y Y Y I Bus Mode Y Y N Y Y N Y Y Y Y Y Y Y Y J Memory Scale up Board K Secure Boot L Memory Operation Mode Normal Y Y Y Y Y Y Y N ...

Page 148: ......

Reviews: