PortGroup Name VLAN ID Used Ports Uplinks
VM Network 0 0
Service Console 0 1
Execute the esxcfg-vswitch command to connect the physical adapter vmnic1 to vSwitch0.
# esxcfg-vswitch -L vmnic1 vSwitch0
# esxcfg-vswitch -l
Switch Name Num Ports Used Ports Configured Ports \
MTU Uplinks
vSwitch0 64 2 64 \
1500 vmnic1
PortGroup Name VLAN ID Used Ports Uplinks
VM Network 0 0 vmnic1
Service Console 0 1 vmnic1
4. Execute the esxcfg-vswif command to assign the IP address (192.168.0.2) to vswif0.
# esxcfg-vswif -i 192.168.0.2 -n 255.255.255.0 vswif0
# esxcfg-vswif -l
Name Port Group/DVPort IP Family IP Address \
Netmask Broadcast Enabled TYPE
vswif0 Service Console IPv4 192.168.0.2 \
255.255.255.0 192.168.0.255 true STATIC
\: This indicates that there is no line feed.
Configuring the PSA-to-MMB communication LAN
1. Execute the esxcfg-vswitch command to create a virtual switch (vSwitch1).
# esxcfg-vswitch -a vSwitch1
# esxcfg-vswitch -l
Switch Name Num Ports Used Ports Configured Ports \
MTU Uplinks
vSwitch0 64 2 64 \
1500 vmnic1
PortGroup Name VLAN ID Used Ports Uplinks
VM Network 0 0 vmnic1
Service Console 0 1 vmnic1
vSwitch1 64 2 64 \
1500
PRIMEQUEST 1000 Series Installation Manual
APPENDIX E Notes on VMware Installation
273
C122-E107-09EN