C141-E106-01EN
3 - 12
open
Host detected CBLID- below V
IL
Host
Device 0
Device 1
with 80-conductor cable
with 40-conductor cable
PDIAG-: CBLID- conductor
PDIAG-: CBLID- conductor
Host detected CBLID- above V
IH
Host
Device 0
Device 1
Figure 3.12 Cable type detection using CBLID- signal
(Host sensing the condition of the CBLID- signal)
open
0.047
µ
F
±10% or
±20%
Host
Device 0
Device 1
with 80-conductor cable
with 40-conductor cable
PDIAG-:CBLID- conductor
PDIAG-:CBLID- conductor
IDENTIFY DEVICE information
word 93 bit13:1
Device detected CBLID- above V
IH
IDENTIFY DEVICE information
word 93 bit13:0
Device detected CBLID- below V
IL
Host
Device 0
Device 1
0.047
µ
F
±10% or
±20%
Figure 3.13 Cable type detection using IDENTIFY DEVICE data
(Device sensing the condition of the CBLID- signal)