359
CHAPTER 16 I
2
C INTERFACE
16.4 Operation of I
2
C Interface
The I
2
C bus establishes communication via two duplex bus lines, one serial data line
(SDA) and one serial clock line (SCL). The I
2
C interface has two open-drain input pins
(SDA and SCL) to make the wiring possible.
■
I
2
C interface operation
❍
Start conditions
When the MSS bit is set to 1 while the bus is open (BB=0, MSS=0), the I2C interface is put in
master mode and generates a start condition. Even if the bus is being used (BB=1) in master
mode, another start condition can be generated by setting the SCC bit to 1.
Start conditions can be generated in the following two ways.
•
Setting the MSS bit to 1 by writing when the bus is not used (MSS=0, BB=0, INT=0, AL=0).
•
Write 1 to the SCC bit in interrupt state when the bus is in master mode (MSS=1, BB=1,
INT=1, AL=0).
If the MSS bit is set to 1 by writing when another system (idling) is using the bus, the AL bit is
set to 1. Any attempt other than as described above to set the MSS and SCC bits to 1 is not
effective.
❍
Stop conditions
If the MSS bit is set to 0 by writing in master mode (MSS=1), a stop condition is generated and
the I2C interface is put into slave mode.
Stop conditions are generated under the following conditions:
•
Setting the MSS bit to 0 by writing interrupt state when the bus is in master mode
(MSS=1,BB=1,INT=1,AL=0).
•
Any attempt other than as described above to set the MSS bit to 0 is ignored.
❍
Addressing
In master mode, after a start condition is generated, the I2C interface is set to BB=1 and
TRX=1, and the contents of the IDAR register are output, starting from the MSB. If Acknowledge
is received from the slave after address data is transmitted, bit 0 of the transmitted data (bit 0 of
the posttransmission IDAR register) is set to the other value, which is stored in the TRX bit.
In slave mode, after a start condition is generated, the I2C interface is set to BB=1 and TRX=0,
and the data transmitted from the master is received by the IDAR register. After the address
data is received, the contents of the IDAR register are compared with those of the IADR
register. If both values match, AAS=1 is set and Acknowledge is transmitted to the master.
Then, the value of bit 0 of the received data (bit 0 of the postreception IDAR register) is stored in
the TRX bit.
Summary of Contents for MB91150 Series
Page 1: ......
Page 2: ......
Page 3: ...FUJITSU LIMITED FR30 32 BIT MICROCONTROLLER MB91150 Series HARDWARE MANUAL ...
Page 4: ......
Page 10: ...vi ...
Page 112: ...96 CHAPTER 3 MEMORY SPACE CPU AND CONTROL UNIT ...
Page 178: ...162 CHAPTER 5 I O PORTS ...
Page 214: ...198 CHAPTER 7 16 BIT RELOAD TIMER ...
Page 240: ...224 CHAPTER 8 PPG TIMER ...
Page 310: ...294 CHAPTER 13 8 10 BIT A D CONVERTER ...
Page 318: ...302 CHAPTER 14 8 BIT D A CONVERTER ...
Page 362: ...346 CHAPTER 15 UART ...
Page 420: ...404 CHAPTER 19 PERIPHERAL STOP CONTROL ...
Page 428: ...412 CHAPTER 20 CALENDAR MACROS ...
Page 503: ...487 INDEX INDEX The index follows on the next page This is listed in alphabetic order ...
Page 510: ...494 INDEX ...
Page 512: ......