C141-E205
4-7
1
3
4
2
5
Figure 4.6 Surface temperature measurement points
(5)
Service clearance area
The service clearance area, or the sides which must allow access to the IDD for installation or
maintenance, is shown in Figure 4.7.
[Surface Q]
•
Hole for mounting screw
[Surface R]
•
Hole for mounting screw
[Surface P]
•
Cable connection
[Surface P']
•
Setting terminal (MP model only)
•
External operator panel connector
Figure 4.7
Service clearance area
(6)
External magnetic field
The drive should not be installed near the ferromagnetic body like a speaker to avoid the influence
of the external magnetic field.
(7)
Leak magnetic flux
The IDD uses a high performance magnet to achieve a high speed seek. Therefore, a leak
magnetic flux at surface of the IDD is large. Mount the IDD so that the leak magnetic flux does
not affect to near equipment.