Fujitsu Halcyon ASUG09-12LMAS Operating Manual Download Page 6

En-5

5.  AIRFLOW SETTINGS

5.1.  Fan speed setting

)

)

 Press 

 to control the fan speed.

The fan speed changes as follows.

(Auto)

(High)

(Med)

(Low)

(Quiet)

When 

 is selected, the fan speed depends on the operating 

condition.

To increase the air cleaning effect, set the fan speed to High.

5.2.  Airflow direction setting

For details of the airflow ranges, refer to "Airflow direction 

range".

 

Vertical airflow direction setting

)

)

Press 

 to adjust the vertical airflow direction.

 

Horizontal airflow direction setting

)

)

Press 

 to adjust the horizontal airflow direction.

 

Swing operation setting

)

)

Press 

 to select the Swing operation.

The Swing operation changes as follows.

 Up/down 

Left/right 

Up/down/left/right 

Stop swing

NOTES:

 The Swing operation may stop temporarily when the indoor 

unit fan is rotating at very low speed or is stopped.

6.  TIMER OPERATIONS

NOTES: 

When [   ] indicator on the indoor unit blinks, set the clock 

and timer again. This blinking shows that the internal clock go 

wrong due to an interruption of the power supply. (Refer to 

page 10.)

 

Timer setting procedure

Before setting the timer, please adjust the clock. (Refer to "remote 

controller preparation").

1. 

Press 

.

 on the remote controller display will blink.

2. 

Press 

(

)

 to choose timer operation.

The timer operation will change as follows:

[

]

[

]

[

]

Weekly timer

Enables you to set operation 

schedules up to 4 setting for each 

day of the week.

On timer

Starts the operation at your desired 

time.

Off timer

Stops the operation at your desired 

time.

Program timer Operates as the combination of the 

On timer and Off timer.

Sleep timer

Supports your comfortable sleep 

by moderating the air conditioner 

operation gradually.

3. 

Press 

.

4. 

Set each timer operation.

For details, refer to the following instructions of each timer setting.

5. 

Press 

 to complete the timer setting.

Be close to the indoor unit.

•  To cancel the timer setting during the procedure, press 

 

again.

4.  BASIC OPERATIONS

 

3 steps to start operation

1. 

Press 

 to start or stop the operation.

2. 

Press 

 to select the operation mode.

The operation mode changes as follows.

AUTO   

COOL  

DRY   

FAN   

HEAT

3. 

Press 

 to set the desired temperature.

The temperature changes by 0.5 °C increments.

Temperature setting range

Auto/Cooling/Dry

18.0 - 30.0 °C

Heating

16.0 - 30.0 °C

NOTES:

•  In the Cooling or Dry mode, set the temperature lower than the 

current room temperature.

•  In the Heating mode,

 -set the temperature higher than the current room temperature.

 -at the beginning of the operation, the indoor unit fan rotates at very 

low speed for 3-5 minutes.

 -the Automatic defrosting operation overrides the Heating operation 

when necessary.

•  In the Fan mode, temperature control is not available. 

 

Temperature unit switching

1. 

Press 

 until only the clock is displayed.

2. 

Press down 

 for more than 5 seconds.

The current temperature unit will be displayed. (Factory setting: °C)

3. 

Press 

 to switch the temperature unit. (°C 

°F)

4. 

Press 

 to finish the setting.

If you do not press the button for 30 seconds, the displayed 

temperature unit will be set.

 

Airflow direction range

Vertical airflow direction

1

2

3

4

5 6

Change by 

 

1

2

3

4

5

6

Swing operation by 

Cooling, Dry

1

4

Heating

3

6

Fan *

1

4 or 3

6

* the Swing operation range depends on the airflow direction set before 

the Swing operation.

NOTES:

• 

Do not adjust the airflow direction louvers by hand.

• 

In the Auto or Heating mode, the airflow direction stay position 1 for 

a while from the start of the operation.

•  In the Cooling or Dry mode, position 1-3 is recommended to prevent 

condensation drips damaging your property. If position 4-6 keeps for 

30 minutes or more in these modes, the airflow direction changes to 

position 3 automatically.

•  When using the mobile app (optional wireless LAN control is 

necessary), the vertical airflow can be selected from 4 positions.

Horizontal airflow direction

3

4

5

2

1

Change by 

 

1

2

3

4

5

Swing operation 

by 

1

5

NOTES: 

In the Auto mode operation, you cannot change the airflow 

direction for a while from the start of the operation.

Summary of Contents for Halcyon ASUG09-12LMAS

Page 1: ...tions codes installation operation manuals before the installation maintenance or service of this product AIR CONDITIONER MODEL Wall Mounted Type OPERATING MANUAL Before using this product read these instructions thoroughly Also keep this manual for future reference together with the installation manuals for the indoor and outdoor units PART No 9387602029 02 Please write down the model name Refer ...

Page 2: ...duct or the power source to prevent any electrical hazards This product shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater This product shall be stored in a well ventilated area Be aware that refrigerants may not contain an odour This product shall be stored so as to prevent mechanical damage ...

Page 3: ...ects This may cause quality deterioration of those items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable Do not touch the aluminum fins of heat exchanger built in this product to avoid personal injury when you maintain the unit Do not stand on unstable steps when operating or cleaning this product It may ov...

Page 4: ...7 Activates or deactivates the Economy operation Activates or deactivates the Energy saving program that uses the human sensor For Basic operations Refer to page 5 Starts or stops the air conditioner operation Changes the operation mode Adjusts the setting temperature For Outdoor Unit Low Noise operation Refer to page 8 Activates or deactivates the Outdoor Unit Low Noise operation Remote controlle...

Page 5: ...tting to the next step Returns the timer or clock setting to the previous step By pressed down activates or deactivates the wireless LAN control Refer to page 12 Adjusts the value of the timer or clock settings Starts the clock setting After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET CAUTION To prevent malfunction...

Page 6: ...ain 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode changes as follows AUTO COOL DRY FAN HEAT 3 Press to set the desired temperature The temperature changes by 0 5 C increments Temperature setting range Auto Cooling Dry 18 0 30 0 C Heating 16 0 30 0 C NOTES In the Cooling or Dry mode set the temperature lo...

Page 7: ...ed remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Program 4 On Off On Off 26 C 28 C Wake up Leave for work Come back home Go to sleep Saturday No timer settings Sunday Program 1 Program 2 Program 3 Progr...

Page 8: ...cts infrared light given out by people the detection may be incorrect in the following situations Situations in which the sensor may detect no one in the room even when there is someone there When the room temperature is high and the difference with people s body temperature is small Such as when the temperature is 30 C or higher in summer When someone in the room do not move for a long time When ...

Page 9: ...k display To change the air conditioner custom code contact an authorized service personnel initially set to A If you do not press any buttons for 30 seconds after the custom code is displayed the display returns to the clock display In this case repeat the setting from step 2 Depending on the remote controller the custom code may return to A when replacing the batteries In this case reset the cus...

Page 10: ... handle disconnect the two lower tabs and pull out Air filter handle Hooks 2 places 3 Remove the dust in either of the following ways Cleaning with vacuum cleaner Washing with mild detergent and warm water After washing dry the air filters thoroughly in shade 4 Replace the air filters Align the sides of the air filter with the panel and push in fully Make sure to the two lower tabs are returned to...

Page 11: ...owing Indicator lamp Blinking pattern Blinks 3 times at intervals of 21 seconds After cleaning reset the filter indicator by pushing on the indoor unit for 2 seconds or less 11 GENERAL INFORMATION Heating performance This air conditioner operates on the heat pump principle absorbing heat from air outdoors and transferring that heat to the indoor unit As a result the operating performance is reduce...

Page 12: ...ser registration 1 Open the installed mobile app 2 Register the user with either a smartphone or tablet PC by following the instructions in the create an account section of the mobile app Step 3 Installing W LAN adapter CAUTION Be sure to turn off the power supply of the air conditioner when installing or removing this product to avoid the risk of electric shock Do not put fingers sticks etc in th...

Page 13: ...y 3 Press 4 Select using on the remote controller 5 Press The indoor unit enters Button mode and indicator on the indoor unit will blink on off 1sec 1sec When the W LAN adapter find a connectable W LAN access point the blinking will become slowly on off 2sec 0 5sec NOTES If the connection to W LAN access point is not be finished in several minutes Button mode is canceled and turns off In this case...

Page 14: ...eries Operation is delayed after restart Has the power supply turned from Off to On suddenly In this case the compressor will not operate for about 3 minutes to prevent a blowout of the fuse Immediately stop operation and turn off the electrical breaker in following cases Then consult authorized service personnel The problem persists even if you perform these checks or diagnostics On the indoor un...

Page 15: ... Check that the power to the wireless router is on There is a possibility that the W LAN adapter is not properly connected to the wireless router 11 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the W LAN adapter is being updated During the air conditioner registration pairing of W LAN adapter 12 Restricted function 11 Manual Auto operat...

Page 16: ......

Reviews: