5. Thermistor resistance values
5-1. Indoor unit
¢
Room temperature thermistor
Temperature (°C)
Resistance (kΩ)
Voltage (V)
-10.0
58.25
0.73
-5.0
44.03
0.93
0.0
33.62
1.15
5.0
25.92
1.39
10.0
20.17
1.66
15.0
15.84
1.94
20.0
12.54
2.22
25.0
10.00
2.50
30.0
8.04
2.77
35.0
6.51
3.03
40.0
5.30
3.27
45.0
4.35
3.48
¢
Heat exchanger temperature thermistor
Temperature (°C)
Resistance (kΩ)
Voltage (V)
-30.0
1,131.91
0.21
-25.0
804.52
0.29
-20.0
579.59
0.40
-15.0
422.89
0.53
-10.0
312.27
0.69
-5.0
233.21
0.88
0.0
176.03
1.10
5.0
134.23
1.36
10.0
103.34
1.63
15.0
80.28
1.92
20.0
62.91
2.21
25.0
49.70
2.51
30.0
39.57
2.79
35.0
31.74
3.06
40.0
25.64
3.30
45.0
20.85
3.53
50.0
17.06
3.73
55.0
14.05
3.90
60.0
11.64
4.05
65.0
9.69
4.19
5-1. Indoor unit
- (03-49) -
5. Thermistor resistance values
TROUBLESHOOTING
TROUBLESHOOTING
Summary of Contents for General AOHH30KMTB
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 07 19 SR_CH01_AS073EG_02 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 07 19 SR_CH02_AS073EG_01 ...
Page 33: ...3 TROUBLESHOOTING 2022 08 22 SR_CH03_AS073EG_01 ...
Page 36: ......
Page 90: ...5 2 Outdoor unit 03 54 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 91: ...4 CONTROL AND FUNCTIONS 2022 08 22 SR_CH04_AS073EG_01 ...
Page 94: ......
Page 129: ...5 FILED WORKING 2022 08 22 SR_CH05_AS073EG_01 ...