1. Specifications
Type
Inverter heat pump
Model name
AOHG30KMTA
AOHG36KMTA
Power supply
230 V ~ 50 Hz
Power supply intake
Outdoor unit
Available voltage range
198—264 V
Starting current
A
10.2
13.9
Fan
Airflow rate
Cooling
m
3
/h
3,750
Heating
3,750
Type × Q'ty
Propeller × 1
Motor output
W
100
Sound pressure level*
1
Cooling
dB (A)
53
55
Heating
55
55
Sound power level
Cooling
dB (A)
68
70
Heating
69
70
Heat exchanger type
Dimensions
(H × W × D)
mm
Main1: 756 × 905 × 18.19
Main2: 756 × 905 × 18.19
Fin pitch
1.45
Rows × Stages
1 × 36
Pipe type
Copper
Fin
Type (Material)
Aluminum
Surface treatment
Blue fin
Compressor
Type × Q'ty
DC Twin rotary × 1
Motor output
W
1,500
Refrigerant
Type (Global warming potential)
R32 (675)
Factory charge
g
1,900
Refrigerant oil
Type
FW68D
Amount
cm
3
600
Enclosure
Material
Steel sheet
Color
Beige
Approximate color of Munsell 10YR 7.5/1.0
Dimensions
(H × W × D)
Net
mm
788 × 940 × 320
Gross
966 × 1,027 × 445
Weight
Net
kg
52
Gross
60
Connection pipe
Size
Liquid
mm (in)
Ø9.52 (3/8)
Gas
Ø15.88 (5/8)
Method
Flare
Pre-charge length
m
30
Max. length
50
Max. height difference
30
Operation range
Cooling
°C
-15 to 46
Heating
-15 to 24
Drain hose
Material
LDPE
Size
mm
Ø13.0 (I. D.), Ø16.0 to Ø16.7 (O. D.)
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5.0 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
- 36 -
1. Specifications
OUTDOOR UNIT
AOHG30-36KMTA
OUTDOOR UNIT
AOHG30-36KMTA