![Fujitsu General AOHG07KMCC Service Manual Download Page 150](http://html.mh-extra.com/html/fujitsu/general-aohg07kmcc/general-aohg07kmcc_service-manual_2343861150.webp)
2-4. Details of function
¢
Control input function
•
When function setting is “Operation/Stop” mode 1
– In the case of “Edge” input:
Function
setting
Rotary SW on External
input and output PCB
External input
Input signal
Command
46-00
1
External input and
output PCB
CN313
Off → On
Operation
On → Off
Stop
Operation
Stop
Remote controller
On
Off
Indoor unit
On
CN313
– In the case of “Pulse” input:
Function
setting
Rotary SW on External
input and output PCB
External input
Input signal
Command
46-00
1
External input and
output PCB
CN313
Pulse
Operation
CN314
Pulse
Stop
On
On
Off
Operation
Stop
Remote controller
On
Off
Indoor unit
CN313
CN314
NOTES:
• The last command has priority.
• The indoor units within the same remote controller group operates in the same mode.
2-4. Details of function
- (05-16) -
2. External input and output
FIELD
WORKING
FIELD
WORKING