5.1 Tools Setup Sequence
Start the debugging system in the following sequence:
9
Select mode switch on Easy EV-Board to debug mode;
9
Connect Easy Kit to PC USB interface;
9
The Easy Kit will be recognized as “BGM Adaptor (MB2146-08)” in Windows.
5.2 Open Project and Start Debug
Users can start debug from SOFTUNE in the following sequence. Here take IO_LED project
for example.
9
Start the SOFTUNE by selecting
Program
>
SOFTUNE V3
>
FFMC-8L Family
SOFTUNE Workbench
from
Start
Menu in Windows;
9
Click
Open Workspace
from
File
Menu in SOFTUNE;
9
Select
IO_LED.wsp
in
Open Space
window;
9
Click
Start Debug
from
Debug
Menu.
If the entire procedure goes right, a debug will start normally.
5.3 Operation Precautions
9
All pins of MB95200 Series MCU are directly connected to Easy EV-board 20 pin
interface. If the user wants to connect these pins out, it’s recommended to add terminal
resistors in series with the pins.