Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED
P3AM-4842-12ENZ0
149
A.2.5
Test Messages
The messages that are sent when the test notification of an event is performed in ETERNUS Web GUI or
ETERNUS CLI are described below.
■
Test mail transmission
The message is notified when the test notification of e-mail is performed in ETERNUS Web GUI or ETERNUS CLI.
■
Test Trap transmission
The message is notified when the test notification of the SNMP Trap is performed in ETERNUS Web GUI or
ETERNUS CLI.
A.2.6
Sense Codes
This section describes the sense codes that are notified to the server.
Event type code
Message
T FFFFFFFF
Test e-mail Message
Trap No.
TrapItemId
TrapMessage
2
0x80000000
SNMP Trap Test
The Trap No. and ItemId in the test Trap are the same as the notification that is sent when a drive in Slot#0 in
CE is in Fault status. A drive is not actually disconnected when a test Trap is notified.
Sense code
Description
Remarks
SK
ASC
ASCQ
02
04
00
The device is in Not Ready status.
This sense code is notified when "Not
ready" is enabled for Error Severity Level
in the event notification setting.
This is not notified during maintenance
operations.