Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED
P3AM-4842-12ENZ0
113
A.2.2
Error Messages
This section describes the messages that are sent when the severity is Error for each type of event.
■
Error message list
●
When the event type is "P"
The following messages are sent when components fail or degrade or when a temperature error is
detected.
Event type
code
SNMP Trap
Upper: Message
Remarks
Trap
No.
TrapItemID
Trap
Sensor
Info
Lower: Description
P 01
SSMM
00
2
0100
MM
00
-
Controller Module#
m
(
zz
) Fault <
pppppppppppp
ssssssssss rrrrr
>
These messages are
notified when "Parts
Error" is enabled for
Error Severity Level in
the event notification
setting.
They are not notified
during maintenance
operations.
CM is disconnected.
SS
: Component subtype
MM
: CM module ID (10 – 11)
m
: CM number (0 – 1)
zz
: Model name (DX80S2 or DX90S2)
pp...
: Component number
ss...
: Serial number
rr...
: Version
P 02
SSMM
0
p
2
0200
MM
0p
-
Controller Module#
m
(
zz
) DMA PORT#
p
Fault
<
pppppppppppp ssssssssss rrrrr
>
CM DMA port is disconnected.
SS
: Component subtype
MM
: CM module ID (10 – 11)
m
: CM number (0 – 1)
zz
: Model name (DX80S2 or DX90S2)
p
: Port number (0 – 1)
pp...
: Component number
ss...
: Serial number
rr...
: Version
P 03
SSMM
0
v
2
0300
MM
0v
-
Controller Module#
m
(
zz
) BIOS#
v
Fault
<
pppppppppppp ssssssssss rrrrr
>
CM BIOS is disconnected.
SS
: Component subtype
MM
: CM module ID (10 – 11)
m
: CM number (0 – 1)
zz
: Model name (DX80S2 or DX90S2)
v
: Device number (0 – 1)
pp...
: Component number
ss...
: Serial number
rr...
: Version
P 04
SSMM
00
2
0400
MM
00
-
Controller Module#
m
(
zz
) RTC Fault
<
pppppppppppp ssssssssss rrrrr
>
CM RTC is disconnected.
SS
: Component subtype
MM
: CM module ID (10 – 11)
m
: CM number (0 – 1)
zz
: Model name (DX80S2 or DX90S2)
pp...
: Component number
ss...
: Serial number
rr...
: Version