Chapter 7 Setup
7.4 Monitoring Setup
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
175
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
8
Click the [Send Test E-mail] button to check that an E-mail can be sent to the
specified E-mail destination address.
Figure 7.36 Send Test E-mail
End of procedure
7.4.3
ServerView (SNMP Trap Notification) Setup
This section explains how to perform settings to monitor event notification (Trap) by SNMP using
the "ServerView" server monitoring tool.
For details on server settings, refer to the manual that is provided with ServerView.
Also, for events that are detected by ServerView when monitoring the device, refer to
B Events detected by ServerView" (page 233)
Procedure
1
Set the network environment of the ETERNUS DX60/DX80/DX90.
When the ETERNUS DX60/DX80/DX90 and ServerView management device are in differ-
ent subnet environments, set the Gateway IP address and destination network address in
the [Setup Network Environment] screen of GUI.
1-1
Start GUI.
1-2
Click [Setup Network Environment] under the [Network Settings] menu on the [Global
Settings] tab in the GUI screen.
The [Setup Network Environment] screen appears.
Refer
Manual provided with ServerView