Chapter 6 Cable Connection
6.6 MiniSAS Cable Connection (For Drive Enclosures)
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
118
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
2
Connect the miniSAS cables to the server.
Connect the other end of the miniSAS cables to the server's SAS cards.
End of procedure
6.6
MiniSAS Cable Connection (For Drive Enclosures)
When a Drive Enclosure is installed, connect the Drive Enclosure to the Controller Enclosure
with a miniSAS cable. When multiple Drive Enclosures are installed (only for ETERNUS DX80/
DX90), connect the Drive Enclosures with miniSAS cable.
Two miniSAS cables (75cm) are supplied with each Drive Enclosure dual expander model, and
one miniSAS cable (75cm) with each Drive Enclosure single expander model.
CAUTION
Do
•
When connecting the SAS cables, position them so that they
will not obstruct replacement of the power supply unit or
controllers by the maintenance engineer.
CAUTION
Do
•
Make sure to wear a wrist strap before starting each operation, as
failure to discharge static electricity may cause a device failure.
Do not remove it until the operation is complete.
•
When connecting external (signal, power, etc.) cables, avoid pulling
them as it may cause device damage.
Do Not
•
Do not bend the cable too much or bind it up. Doing so may cause a
device damage or failure.
90
Do not bend square
Do not bind up