Chapter 6 Cable Connection
6.4 LAN Cable Connection (For iSCSI)
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
114
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
3
Connect the other end of the Fibre Channel cable to the server or Fibre Channel
switch.
3-1
Remove the covers from the Fibre Channel cable connectors.
3-2
Connect the Fibre Channel cable to the Fibre Channel adapter in the server or Fibre
Channel switch.
End of procedure
6.4
LAN Cable Connection (For iSCSI)
Connect the ETERNUS DX60/DX80 and the server or switching hub with LAN cables (enhanced
Cat-5 type).
User must prepare their own LAN cables.
CAUTION
Do
•
When connecting the Fibre Channel cables, position them so
that they will not obstruct replacement of the power supply
unit or controllers by the maintenance engineer.
IMPORTANT
•
Use a separate LAN for the iSCSI connection.
•
The iSCSI interface operates in 1000Base-T full-duplex mode.
•
When connecting the ETERNUS DX60/DX80 and the server via a
switching hub, the switching hub must be able to support 1Gbit/s con-
nection.
CAUTION
Do
•
Be sure to wear a wrist strap or discharge static electricity by
touching the metal frame of the ETERNUS DX60/DX80 before
starting each operation, as failure to discharge static electricity may
cause device failure.
•
When connecting external (signal, power, etc.) cables, avoid pulling
them as it may cause device damage.