Remote Connections
An FC or iSCSI interface is available for a remote connection.
When a remote connection is used, change the host interface port mode setting from "CA" to "RA".
For remote connections, different types of interfaces (FC, iSCSI 10Gbit/s, iSCSI 1Gbit/s) cannot exist together
on a REC path (connection between a local ETERNUS DX/AF and a remote ETERNUS DX/AF).
When different types of remote interfaces exist in the same ETERNUS DX/AF, make sure to use the same type
of interface for each REC path. For example, the following configuration is not supported because different
types of interfaces (FC and iSCSI) exist together on a REC path.
Figure 91 Example of Non-Supported Connection Configuration (When Multiple Types of Remote Interfaces
Are Installed in the Same ETERNUS DX/AF)
FC-RA
iSCSI-RA
FC-RA
REC path
iSCSI-RA
ETERNUS DX/AF
ETERNUS DX/AF
The following configuration is supported because the same type of interface is used for each REC path.
Figure 92 Example of Supported Connection Configuration (When Multiple Types of Remote Interfaces Are In-
stalled in the Same ETERNUS DX/AF)
FC-RA
FC-RA
ETERNUS DX/AF
ETERNUS DX/AF
ETERNUS DX/AF
FC-RA
FC-RA
iSCSI -RA
iSCSI -RA
iSCSI -RA
iSCSI -RA
REC path
REC path
4. Connection Configuration
Remote Connections
149
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Design Guide (Basic)