Chapter 4 Connectivity Management
4.8 NAS Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
523
3
Click the [Done] button to return to the [Quota Management] screen.
End of procedure
4.8.12
Modify Quota Setting
This function changes the quota setting information. Drive space and file count thresholds (Warning and
Limit) can be changed.
Quota is a threshold for the usable space that is set on each user and group to prevent the depletion of
resources in the ETERNUS DX.
This function is displayed in a Unified Storage environment.
For details on the parameters for this function, refer to
"A.4.7.9 Modify Quota Setting" (page 901)
.
•
Quota is set for users or groups that are registered in the authentication server. When using this function,
registering the users or groups in the authentication server in advance is necessary.
•
This function sets two thresholds (Warning and Limit) for the drive space or the file count.
-
When exceeding the warning threshold
This is a predictive notification and writing to the relevant NAS user volume is not prohibited.
-
When exceeding the limit threshold
Writing to the relevant NAS user volume is prohibited.
•
A total of four threshold values can be set (two for the drive space and two for the file count) in a single
quota setting information. However, specifying "0" for all the thresholds (which includes changing the
drive space value to "Not Specified") is not allowed. At least one threshold must have a valid value.
•
The type (of User/Group) and name (of the User/Group) of the quota setting target information cannot be
changed. To change the "Type" or "Name", delete the relevant quota setting information and add the
setting again.
•
Event notifications for the conditions described below can be sent using the specified method. Refer to
"1.9.1 Setup Event Notification" (page 144)
for details.
-
The drive space or the file count has exceeded the threshold
-
The drive space or the file count has returned to a normal state below the threshold value
•
The quota setting information can be added. Refer to
"4.8.10 Add Quota Setting" (page 517)
for details.
•
The quota setting information in the ETERNUS DX can be deleted. Refer to
for details.
•
The quota setting information in the ETERNUS DX can be checked. Refer to "Quota Management" in
"ETERNUS Web GUI User's Guide (Operation)" for details.
Summary of Contents for Eternus DX200F