4.2
Rebuild/Copyback Process Time
This section explains the time required for Rebuild/Copyback.
■
Rebuild Process Time
The following table shows the time required for the rebuild process.
Table 4.2 Rebuild Process Time
RAID level
Number of drives
Rebuild process time (*1)
SSDs
RAID1
2 (1D+1M)
Approx. 9 minutes/200GB
RAID1+0
4 (2D+2M)
Approx. 5 minutes/200GB
RAID5
5 (4D+1P)
Approx. 3 minutes/200GB
RAID5+0
8 ((3D+1P)
´
2)
Approx. 2 minutes/200GB
RAID6
6 (4D+2P)
Approx. 3 minutes/200GB
*1: The value shows the rebuild process time when the volume capacity is 200GB and there is no server I/O.
The time that is required depends on the type and configuration of the drive.
■
Copyback Process Time
The following table shows the time required for the copyback process.
Table 4.3 Copyback Process Time
RAID level
Number of drives
Copyback process time (*1)
SSDs
RAID1
2 (1D+1M)
Approx. 9 minutes/200GB
RAID1+0
4 (2D+2M)
Approx. 5 minutes/200GB
RAID5
5 (4D+1P)
Approx. 3 minutes/200GB
RAID5+0
8 ((3D+1P)
´
2)
Approx. 2 minutes/200GB
RAID6
6 (4D+2P)
Approx. 3 minutes/200GB
*1: The value shows the copyback process time when the volume capacity is 200GB and there is no server
I/O. The time that is required depends on the type and configuration of the drive.
[Set RAID Group Parameter] specifies the rebuild priority for host access. When the Rebuild Priority is
"High", rebuild, copyback, and redundant copy performance can be improved.
Note that RAID group performance (throughput) may be reduced when a rebuild, copyback, or redundant
copy is being performed in the target RAID group.
Chapter 4 Process Time (Estimated)
4.2 Rebuild/Copyback Process Time
47
FUJITSU Storage ETERNUS AF650 S2, ETERNUS AF650 All-Flash Arrays Operation Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1932-04ENZ0