Double Striping Configuration with Distributed Parity
RAID5+0(2D+1P)
´
2 is used in the following examples to explain how to install drives that are configured for
double striping with distributed parity.
The drive number is determined by the DE-ID of the enclosure and the slot number in which the drive is
installed. Drives are divided into two redundant set groups in ascending order of drive numbers.
Example 4: Drives are installed in two different drive enclosures
Figure 125
Drive Combination 4
DE#00
A
D
B
DE#10
E
C
F
:
Redundancy Group 1
:
Redundancy Group 2
Example 5: Drives are installed in three different drive enclosures
Figure 126
Drive Combination 5
F
C
B
E
A
D
DE#00
DE#10
DE#20
:
Redundancy Group 1
4. Hardware Configurations
Recommended RAID Group Configuration
182
Design Guide
Summary of Contents for ETERNUS AF S3 Series