Remote Connections
An FC or iSCSI interface is available for a remote connection.
When a remote connection is used, change the host interface port mode setting from "CA" to "RA".
Caution
When different types of remote interfaces exist in the same ETERNUS AF/DX, make sure to use the same
type of interface for each REC path. For example, the following configuration is not supported because
different types of interfaces (FC and iSCSI) exist together on an REC path.
Figure 91
Example of Non-Supported Connection Configuration (When Multiple Types of Remote
Interfaces Are Installed in the Same ETERNUS AF/DX)
ETERNUS AF/DX
ETERNUS AF/DX
FC-RA
REC path
iSCSI-RA
FC-RA
iSCSI-RA
The following configuration is supported because the same type of interface is used for each REC path.
Figure 92
Example of Supported Connection Configuration (When Multiple Types of Remote Interfaces
Are Installed in the Same ETERNUS AF/DX)
FC-RA
FC-RA
FC-RA
FC-RA
iSCSI -RA
iSCSI -RA
iSCSI -RA
iSCSI -RA
REC path
REC path
ETERNUS AF/DX
ETERNUS AF/DX
ETERNUS AF/DX