background image

Technical Manual - English

System Board D2799
for PRIMERGY TX200 S6 

Technical Manual

Edition July 2010

Summary of Contents for D2799

Page 1: ...Technical Manual English System Board D2799 for PRIMERGY TX200 S6 Technical Manual Edition July 2010 ...

Page 2: ... Copyright and Trademarks Copyright 2010 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other righ...

Page 3: ...rd assemblies and in the mouse and keyboard are limited life components Use of these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reache...

Page 4: ... Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported from Japan or transferred t...

Page 5: ...ual Only for the Japanese market I Although described in this manual some sections do not apply to the Japanese market These options and routines include USB Flash Module UFM CSS Customer Self Service Replacing the lithium battery ...

Page 6: ...Technical Manual D2799 TX200 S6 ...

Page 7: ...ironmental protection 15 3 Features 17 3 1 Overview 17 3 2 Main memory 23 3 2 1 Module population 23 3 2 2 Modes of operation 24 3 2 3 LV DIMM support 25 3 3 PCIe slots 26 3 4 Screen resolution 27 3 5 Temperature system monitoring 27 3 6 Connectors and indicators 29 3 6 1 System board 29 3 6 2 Connector panel 33 3 7 Settings 35 3 7 1 Switches 35 4 Replacing the lithium battery 37 ...

Page 8: ...Technical Manual D2799 TX200 S6 Contents ...

Page 9: ...mat on the ServerView Suite DVD 2 The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server PRIMERGY Abbreviations and Glossary can also be found on the ServerView Suite DVD 2 1 1 Notational conventions The following notational conventions are used in this manual Text in italics indicates commands or menu items Quotation marks indicate names of chapters and terms that a...

Page 10: ...10 Technical Manual D2799 TX200 S6 Notational conventions ...

Page 11: ...ied staff Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original ...

Page 12: ...11801 standard respectively The minimum requirement is a Category 5 shielded cable for 10 100 Ethernet or Category 5e for Gigabit Ethernet Never connect or disconnect data transmission lines during a storm risk of lightning hazard Batteries V CAUTION Incorrect replacement of batteries may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type recomme...

Page 13: ...ays discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always hold components with ESDs at the edges or at the points marked green touch points Do not touch any connectors or conduction path...

Page 14: ... other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp objects screw drivers for leverage Do not damage or modify internal cables or devices Doing so may cause a device failure fire or electric shock Do not touch the circuitry on...

Page 15: ...rver fujitsu com primergy concept for the Japanese market Energy saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for transporting t...

Page 16: ...ons Details regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 333 18010 The device must not be disposed of with domestic waste This device is labeled...

Page 17: ...y up to 2x 6 slots for main memory the number of allowed memory modules is dependent on memory type supports DDR3 800 1066 1333 UDIMM memory modules supports DDR3 800 1066 1333 RDIMM memory modules supports DDR3 1066 1333 LV UDIMM memory modules only supported by processors type X56xx supports DDR3 1066 1333 LV RDIMM memory modules only supported by processors type X56xx minimum 2 GB of memory max...

Page 18: ...ntegrated VGA controller with PCIe x1 interface Matrox G200 8 MB graphic memory available via driver VESA compatible LAN Ethernet controller Intel 82574L Gigabit Ethernet controller PXE 2 0 and iSCSI boot support IPV6 header offloading Storage devices 6x SATA2 3 Gbit s 2x USB 2 0 internal USB backup drives 1x USB Flash Module or 1x internal USB 2 0 memory stick Internal connectors 1x SATA MLC1 con...

Page 19: ...deo connector VGA 1x RJ45 management LAN connector 1x RJ45 shared LAN connector PCI slots 5x PCI Express slots all slots are mechanical x8 2x PCIe x8 slots Gen2 one slot is open on the right side to plug in a x16 graphics card 2x PCIe x4 slots Gen2 1x PCIe x4 slot Gen1 1x PCI slot 32 bit 33 MHz Server Management controller iRMC S2 basic functionalities fan control voltage supervision for onboard v...

Page 20: ...by RTC external serial connectors LAN PCI Express controller and iRMC S2 power on by power button external serial connectors LAN PCI Express controller and iRMC S2 BIOS features Phoenix SecureCore SMBIOS 2 5 DMI MultiProcessor specification Server Hardware Design Guide WfM ACPI support LSI SAS RAID BIOS USB keyboard mouse boot possible from hard disk SATA SAS SCSI USB USB stick CD DVD IDE SATA SAS...

Page 21: ...nctionality You will find a description of CSS functionality in the operating manual of your server USB Flash Module option The system board can be equipped with an USB Flash Module UFM by the manufacturer or by an add on kit The module can be used as optional memory for software e g VMware or as a software dongle I The USB Flash Module can not be used together with an USB device in the internal U...

Page 22: ...OS system for more information refer to the BIOS manual V CAUTION When using the TPM note the program descriptions provided by the third party manufacturers You must also create a backup of the TPM content To do this follow the third party manufacturer s instructions Without this backup if the TPM or the system board is faulty you will not be able to access your data If a failure occurs please inf...

Page 23: ...stalling RDIMM memory modules 96 GB Mixing both types of memory modules is forbidden When using processors type X56xx LV DIMMs low voltage DIMMs can be used ECC with memory scrubbing and with the Single Device Data Correction SDDC function is supported I You will find the descriptions how to install memory modules in the Options Guide of your server 3 2 1 Module population Figure 2 Slots of the ma...

Page 24: ... different modes Independent Channel Mode Allows population of all channels in any order Related to the channels A F DIMM1 must be populated first Works with DIMMs of different clock rates and applies the lowest clock rate Legend required required if 2nd CPU is configured optional same type in bank per CPU optional any type not usable CPU 2 CPU 1 CPU 2 DIMM 1F DIMM 1E DIMM 1D DIMM 2E DIMM 2D DIMM ...

Page 25: ...s the main memory for the applications is reduced to two third 3 2 3 LV DIMM support LV DIMMs will be supplied with 1 35 V instead of the 1 5 V of the NV DIMMs normal voltage DIMMs Anyway LV DIMMs can also be operated with 1 5 V so that mixing of LV DIMMs and NV DIMMs is possible In this case all DIMMs will be operated with 1 5 V When using two LV DIMMs 1333 MHz per channel the operating voltage r...

Page 26: ...or PCIe x4 slot 2 PCIe x41 PCIe x4 slot 3 PCI 32 32 bit 33 MHz PCI slot 4 PCIe x8 PCIe x8 slot slot is open on the right side to plug in a x16 graphics card 5 PCIe x8 PCIe x8 slot 6 PCIe x41 PCIe x4 slot Slot 3 Slot 2 Slot 1 iRMC Battery Slot 4 Slot 5 Slot 6 FAN3 FAN1 PCI 32 Bit 33 MHz PCIe x4 PCIe x4 PCIe x4 PCIe x8 PCIe x8 Serial 2 Gigabit LAN ON 1 2 3 4 IOH SATA 6 SATA 5 Indicate CSS ICH TPM ...

Page 27: ...reliably protect the computer hardware against damage caused by overheating In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The temperature and system monitoring are controlled by the iRMC S2 integrated Remote Management Controller The following functions are supported Temperature monitoring Measurement of the proces...

Page 28: ...level high or falls below warning level low an alert will be generated Cover monitoring Unauthorized opening of the cover is detected even when the system is switched off However this will only be indicated when the system is switched on again System Event Log SEL All monitored events of the system board are signalized via the Global Error LED or CSS LED and recorded in the System Event Log They c...

Page 29: ...4 Battery External connectors Slot 4 Slot 5 Slot 6 Service LAN Serial 1 Management LAN 1 USB 8 7 IOH PWR1 PWR3 PWR2 FAN3 FAN1 FAN4 Frontpanel Intrusion USB1 AUX USB2 AUX DIP switches PC98 SATA 6 SATA 5 SATA MLC1 PCI 32 Bit 33 MHz PCIe x4 PCIe x4 PCIe x4 Indicate CSS LAN 2 USB 4 5 PCIe x8 PCIe x8 ICH Serial 2 Gigabit LAN DIMM2A DIMM1A DIMM2B DIMM1B DIMM2C DIMM1C CPU 1 CPU 2 SMB USB Front FAN2 UFM T...

Page 30: ...or for system fan 4 8 FAN2 Connector for system fan 2 9 USB1 AUX USB1 connector 10 Frontpanel Front panel connector 11 USB2 AUX USB2 connector 12 PC98 Power supply connector PC98 13 USB Front USB connector for USB on the front side 14 SMB I2C signaling connector 15 USB Stick USB stick connector 16 SATA MLC1 SATA MLC1 connector 4 port 17 uSSD Connector for USB Flash Module UFM 18 SATA5 SATA5 connec...

Page 31: ...be disconnected it is possible to indicate the faulty component by pressing the CSS indicate button No Description 1 CSS indicate button Slot 3 Slot 2 Slot 1 DIMM1F DIMM2F DIMM1E DIMM2E DIMM1D DIMM2D iRMC ON 1 2 3 4 Battery Slot 4 Slot 5 Slot 6 IOH PWR1 PWR3 PWR2 FAN3 FAN1 FAN4 Frontpanel Intrusion USB1 AUX USB2 AUX PC98 SATA 6 SATA 5 SATA MLC1 PCI 32 Bit 33 MHz PCIe x4 PCIe x4 PCIe x4 Indicate CS...

Page 32: ...icates a failure CSS component C Identification Blue on Server is identified via the ServerView Operations Manager Blue flashing Local monitor off via AVR D1 board Yellow on AUX voltage available D2 board Green on System running D3 board Red on Configuration error The system board will be held in reset Possible configuration errors are e g old CPU populated CPUs with different FSB requirements pop...

Page 33: ...roller Intel 82574L The LAN controller supports transmission rates of 10 Mbit s 100 Mbit s and 1 Gbit s G CPU Off CPU okay Orange on CPU failure H PCI card Off PCI card okay Orange on PCI card failure No Description 1 Management LAN connector LAN1 for iRMC S2 server management function 2 Shared LAN connector LAN2 3 USB connectors 4 Video connector VGA 5 Serial connector COM1 6 Global error indicat...

Page 34: ...re 8 LAN LEDs No Indicator Description 1 LAN link transfer management LAN Steady green signal when a LAN connection exists Remains dark when no LAN connection exists Flashes green when LAN transfer takes place 2 LAN speed management LAN Steady green signal in the event of a LAN transfer rate of 100 Mbit s Remains dark in the event of a LAN transfer rate of 10 Mbit s 3 LAN link transfer shared LAN ...

Page 35: ...S manual or please call our customer service centre Default Switch Function Status Description S1 1 Recovery BIOS ON Boot block enabled OFF Normal boot S1 2 Reserved S1 3 BIOS flash write protect ON BIOS can only be read OFF BIOS can both be read and written to S1 4 Not used Slot 3 Slot 2 Slot 1 Battery Slot 4 Slot 5 Slot 6 PCI 32 Bit 33 MHz PCIe x4 PCIe x4 PCIe x4 PCIe x8 PCIe x8 Serial 2 ON 1 2 ...

Page 36: ...36 Technical Manual D2799 TX200 S6 Settings ...

Page 37: ...e replaced with an identical battery or a battery type recommended by the manufacturer CR2450 This information doesn t apply to the Japanese market Do not throw lithium batteries into the trash can It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 10 Replacing the li...

Page 38: ...38 Technical Manual D2799 TX200 S6 Replacing the lithium battery ...

Reviews: