background image

Modular RAID Controllers

 

9

2

Important information

In this chapter you will find essential information regarding safety when working 
with the board. Please read the instructions carefully if you want to 
install/remove a board.

V

CAUTION!

Observe the safety notes in the Operating Manual of your system unit.

2.1

Safety instructions

V

CAUTION!

The actions described in these instructions should only be performed 
by authorized, qualified personnel. Equipment repairs should only be 
performed by qualified staff. Any failure to observe the guidelines in 
this manual, and any unauthorized openings and improper repairs 
could expose the user to risks (electric shock, fire hazards) and could 
also damage the equipment. Please note that any unauthorized 
openings of the device will result in the invalidation of the warranty 
and exclusion from all liability.

Transport the device only in the antistatic original packaging or in 
packaging that protects it from knocks and jolts.

Only install extensions that have been released. If you install other 
extensions, you may interfere with the requirements and rules 
governing safety and electromagnetic compatibility of your system. 
Information on which system extensions are suitable can be obtained 
from the customer service center or your sales outlet.

The warranty becomes invalid if the device is damaged during the 
installation or replacement of system extensions.

Components can become very hot during operation. To avoid burns, 
make sure you do not touch components when adding or removing 
system board extensions!

Transmisson cables to peripheral devices must be adequately 
shielded.

Summary of Contents for D2607

Page 1: ...on LSI MegaRAID RAID Ctrl SAS 6G 0 1 D2607 RAID Ctrl SAS 6G 5 6 512MB D2616 PY SAS RAID Mezz Card 6Gb D3016 RAID Ctrl SAS 6G 1GB D3116 PY SAS RAID HDD Module D2816 PY SAS RAID HDD Module w o Cache D2837 PRAID EP400i EP420i PRAID EM400i PRAID CM400i PRAID CP400i PRAID EP420e PRAID EP440i January 2018 ...

Page 2: ...DIN EN ISO 9001 2008 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2008 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright 2018 FUJITSU LIMITED All rights reserved Delivery subject to availabilit...

Page 3: ...gaRAID D2507 15 3 1 1 Features 16 3 1 2 Controller versions 16 3 1 3 Connectors 17 3 1 4 Installation 18 3 2 RAID controller RAID 5 6 SAS based on LSI MegaRAID D2516 21 3 2 1 Features 21 3 2 2 Controller versions 22 3 2 3 Connectors and indicators 23 3 2 4 Installation 24 3 2 5 Installing an optional iBBU module 27 3 2 5 1 Features 27 3 2 5 2 Installation 27 4 Modular RAID 6Gb s SAS2 0 31 4 1 RAID...

Page 4: ... versions 48 4 3 3 Connectors and indicators 49 4 3 4 Installation 50 4 3 5 Installing an optional iBBU module 52 4 3 5 1 Features 52 4 3 5 2 Installation 52 4 4 RAID Controller RAID Ctrl SAS 6G 1GB D3116 54 4 4 1 Features 55 4 4 2 Controller versions 56 4 4 3 Connectors and indicators 56 4 4 4 Installation 58 4 4 5 Installing an optional TFM FBU 60 4 4 5 1 Features 60 4 4 5 2 Installation 60 4 5 ...

Page 5: ...es 80 5 1 5 2 Installation 80 5 2 RAID Controller PRAID EM400i 85 5 2 1 Features 86 5 2 2 Controller versions 86 5 2 3 Connectors and indicators 87 5 2 4 Installation 88 5 3 RAID Controller PRAID CM400i 90 5 3 1 Features 91 5 3 2 Controller versions 91 5 3 3 Connectors and indicators 92 5 3 4 Installation 93 5 4 RAID Controller PRAID CP400i 95 5 4 1 Features 96 5 4 2 Controller versions 96 5 4 3 C...

Page 6: ...rs Content 5 6 RAID Controller PRAID EP440i 107 5 6 1 Features 108 5 6 2 Controller versions 109 5 6 3 Connectors 109 5 6 4 Installation 112 5 6 5 Installing an optional FBU 114 5 6 5 1 Features 114 5 6 5 2 Installation 114 ...

Page 7: ... knowledge in order to install the board To install the software you will need to be familiar with the operating system used 1 2 Further information Information on boards drives and other devices can be found in the manuals you received with these products Information on your operating system and the application programs you are using is contained in the associated manuals or help texts The latest...

Page 8: ...s menu items file and path names or software programs quotation marks indicates names and terms that are being emphasized Ê indicates an operation that is to be performed V CAUTION indicates warnings which if ignored will endanger your health destroy the system or lead to loss of data I indicates additional information notes and tips Table 1 Notational conventions ...

Page 9: ...lease note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packaging or in packaging that protects it from knocks and jolts Only install extensions that have been released If you install other extensions you may interfere with the requirements and rules governing safet...

Page 10: ...tteries into the trash can They must be disposed of in accordance with local regulations concerning special waste Notes about boards During installation uninstallation of a board observe the specific instructions described in the service manual for the server To ensure that the system and system board are completely disconnected from the mains voltage remove the plug from the mains outlet To preve...

Page 11: ...ys discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always hold components with ESDs at the edges or at the points marked green touch points Do not touch any connectors or conduction paths...

Page 12: ...hed on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information does not apply in Japan and APAC Do not throw away the packaging You may need it later for transporting the server If possible the equipment should only be transported in its original packaging Information on handling consumables Please dis...

Page 13: ...bles within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or at http ts fujitsu com recycling The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2012 19 EU on waste electrical and electronic equipment WEEE This directive sets the framework for returning and recycling used equipment and is...

Page 14: ...14 Modular RAID Controllers Important information ...

Page 15: ...notes in chapter Important information on page 9 The RAID controller RAID 0 1 SAS based on LSI MegaRAID is designed to drive the server s internal disk drive The RAID stack is based on LSI MegaRAID and offers powerful data throughput extensive fault tolerance and easy to use management Figure 2 RAID 0 1 SAS based on LSI MegaRAID controllers 1068 A and 1064 B A B ...

Page 16: ... for both SAS and SATA Integrated RAID RAID 0 RAID 1 RAID 1E Supports SSP SMP STB and SATA Protocols Support of the following SATA II features 3 Gbit s SATA Staggered Spin Up Hot Plug Native Command Queuing NCQ Comes without with standard with low profile bracket 3 1 2 Controller versions Name Chip No of SAS channels Bracket type S26361 D2507 B1x D1x LSISAS1064e 4 low profile full height S26361 D2...

Page 17: ...ED connector 2 SAS cable connector s Connector Type Description SAS MLC1 x4 SAS ports 0 3 SFF 8087 Mini SAS connector for SAS IO cable to backplane and HDDs hard disk drives SAS MLC2 x4 SAS ports 4 7 SFF 8087 Mini SAS connector for SAS IO cable to backplane and HDDs HDD LED HDD activity indication LED 8 pin connector Pin 6 to connect activity LED 2 1 2 1 ...

Page 18: ...ack up your data before you change your system configuration To install the new controller proceed as follows Step 1 Unpack the controller Unpack the new controller in a static free environment Remove it from the anti static bag and inspect it for damage If the controller appears to be damaged contact the Fujitsu support service Step 2 Prepare the server Turn off the server and remove the cover fr...

Page 19: ... board as shown in the figure above see your system board guide for information on the PCIe slot Press down gently but firmly to ensure the card is properly seated in the slot Secure the controller to the server chassis with the PCI card hold down latches Connect the SAS and or SATA HDDs located in the system to the SAS cable connector s on the controller ...

Page 20: ...n Utility Run the LSI Logic Configuration Utility to configure the physical arrays and logical drives Press CTRL C immediately to run the utility when the following message appears on the screen Press Ctrl C to start LSI Logic Configuration Utility Step 6 Install the operating system driver The controller can operate under various operating systems To use these operating systems you must install s...

Page 21: ...ased on LSI MegaRAID is designed to drive the server s internal disk drives The RAID stack is based on LSI MegaRAID and offers powerful data throughput extensive fault tolerance and easy to use management Figure 4 RAID 5 6 SAS based on LSI MegaRAID controller 1078 3 2 1 Features Industry proven MegaRAID data protection Flexibility for both SAS and SATA II Advanced management and configuration suit...

Page 22: ... Support of the following SSP features Wide port functionality 2 or 4 Phys from a single quad port Narrow port functionality 1 Phy Compatible with SATA target devices 2 Mini 4x SFF 8087 connectors Hot plug drives SGPIO interfaces for signaling of SAS SATA ports Hardware XOR for RAID parity calculations 72 bit wide 256 512 MB of DDR2 667 with ECC 3 2 2 Controller versions Name Chip Cache No of SAS ...

Page 23: ...icators on the SAS RAID controller Connectors 1 HDD LED connector 2 iBBU connector 3 LEDs 4 SAS cable connectors 5 RAID key holder Connector Type Description SAS MLC1 x4 SAS ports 0 3 SFF 8087 Mini SAS connector for SAS IO cable to backplane and HDDs SAS MLC2 x4 SAS ports 4 7 SFF 8087 Mini SAS connector for SAS IO cable to backplane and HDDs 4 5 1 2 3 ...

Page 24: ...D LED HDD activity indication LED 8 pin connector Pin 6 to connect activity LED iBBU Connector to attach external iBBU LED Description L1 AL Replacement for audible warning L2 CD Write pending data cached Step 1 Unpack the controller Unpack the new controller in a static free environment Remove it from the anti static bag and inspect it for damage If the controller appears to be damaged contact th...

Page 25: ... board as shown in the figure above see your system board guide for information on the PCIe slot Press down gently but firmly to ensure the card is properly seated in the slot Secure the controller to the server chassis with the PCI card hold down latches Connect the SAS and or SATA HDDs located in the system to the SAS cable connector s on the controller ...

Page 26: ...he WebBIOS Configuration Utility to configure the physical arrays and logical drives Press CTRL H immediately to run the utility when the following message appears on the screen Press Ctrl H for WebBIOS Step 6 Install the operating system driver The controller can operate under various operating systems To use these operating systems you must install software drivers The ServerView Suite DVD 1 inc...

Page 27: ...liBBU01 LSliBBU07 supports remote connection to the Modular RAID Controller RAID 5 6 SAS based on LSI MegaRAID The LSliBBU01 LSliBBU07 is not installed directly on the RAID controller Instead use one of the supplied cables to connect the LSliBBU01 LSliBBU07 to the RAID controller The battery backup unit must be mounted inside the chassis I Because server chassis vary there is no standard mounting ...

Page 28: ...able connector LSliBBU01 Figure 7 Position of the cable connector LSIiBBU07 Note the cable connector marked with the red arrow and the holes 1 for the screws that attach the LSliBBU01 LSliBBU07 to the chassis Cable connector Bottom 1 1 1 1 1 1 J2 J5 J4 Cable connector Bottom 1 1 1 ...

Page 29: ... Insert the battery pack harness connector at the end of the colored wires into the J2 connector LSliBBU01 see figure 6 or J4 connector LSliBBU07 see figure 7 on the bottom of the iBBU 4 Connect the cable from the cable connector for LSliBBU01 see figure 6 or for LSliBBU07 see figure 7 on the iBBU to the BBU connector on the RAID controller I The connectors are marked with a black dot to indicate ...

Page 30: ...30 Modular RAID Controllers Modular RAID 3Gb s SAS1 0 ...

Page 31: ...tes in chapter Important information on page 9 The RAID controller RAID 0 1 SAS based on LSI MegaRAID is designed to drive the server s internal disk drive The RAID stack is based on LSI MegaRAID and offers powerful data throughput extensive fault tolerance and easy to use management Figure 9 RAID Ctrl SAS 6G 0 1 D2607 controller based on LSI SAS2008 ...

Page 32: ...CQ support of the following SSP features Wide port functionality 2 3 or 4 Phys from a single quad port Narrow port functionality 1 Phy Compatible with SATA target devices 2 Mini SAS 4i SFF 8087 multilane connectors Drive spin up sequencing control Hot plug drives 1 5 Gbit s 3 0 Gbit s and 6 0 GB s link rates for both SAS and SATA Supported RAID levels RAID 0 1 1E 10 2 SGPIO interfaces for signalin...

Page 33: ... 1 3 Connectors and indicators The following figure shows the location of the connectors and indicators on the SAS RAID controller Name Chip No of SAS channels Bracket type S26361 D2607 Ax LSI SAS2008 8 low profile full height 1 HDD LED connector 3 SAS cable connectors 2 LEDs 1 2 3 ...

Page 34: ...ctor Type Description SAS MLC1 x4 SAS ports 0 3 SFF Mini SAS connector for SAS IO cable to backplane and HDDs SAS MLC2 x4 SAS ports 4 7 SFF 8087 Mini SAS connector for SAS IO cable to backplane and HDDs HDD LED HDD activity indication LED 8 pin connector Pin 6 to connect activity LED LED Description L1 HB Heart Beat L2 ERR Error Step 1 Unpack the controller Unpack the new controller in a static fr...

Page 35: ... the system board as shown in the figure above see your system board guide for information on the PCIe slot Press down gently but firmly to ensure the card is properly seated in the slot Secure the controller to the server chassis with the PCI card hold down latches Connect the SAS and or SATA HDDs located in the system to the SAS cable connector s on the controller Edge of Motherboard Edge of Mot...

Page 36: ...he LSI Logic Configuration Utility Run the LSI Logic Configuration Utility to configure the physical arrays and logical drives Press CTRL H immediately to run the utility when the following message appears on the screen Press Ctrl H to start LSI Logic Configuration Utility Step 6 Install the operating system driver The controller can operate under various operating systems To use these operating s...

Page 37: ...s in chapter Important information on page 9 The RAID controller RAID 5 6 SAS based on LSI MegaRAID is designed to drive the server s internal disk drives The RAID stack is based on LSI MegaRAID and offers powerful data throughput extensive fault tolerance and easy to use management Figure 11 RAID Ctrl SAS 6G 5 6 512 MB D2616 controller based on LSI SAS2108 ...

Page 38: ... card 8 lane 5 0 Gbit PCIe host bus 8 SAS SATA ports Each SAS SATA port supports SSP SMP and STP Support for the following STP features Addressing of SATA targets through expander Native Command Queuing NCQ Support of the following SSP features Wide port functionality 2 or 4 Phys from a single quad port Narrow port functionality 1 Phy Compatible with SATA target devices 2 Mini SAS 4i SFF 8087 conn...

Page 39: ...and indicators The following figure shows the location of the connectors and indicators on the SAS RAID controller Name Chip Cache No of SAS channels Bracket type S26361 D2616 Ax LSI SAS2108 512 MB 8 low profile full height 1 iBBU connector 3 SAS cable connectors 2 LEDs 4 HDD LED connector 1 2 3 4 ...

Page 40: ... Mini SAS connector for SAS IO cable to backplane and HDDs SAS MLC2 x4 SAS ports 4 7 SFF 8087 Mini SAS connector for SAS IO cable to backplane and HDDs HDD LED HDD activity indication LED 8 pin connector Pin 6 to connect activity LED iBBU 1 20 Connector to attach remote iBBU LED Description L1 HB Heart Beat L2 WP Write in cache pending L3 WA Warning 1 2 4 3 6 5 8 7 ...

Page 41: ... your data before you change your system configuration To install the new controller proceed as follows Step 1 Unpack the controller Unpack the new controller in a static free environment Remove it from the anti static bag and inspect it for damage If the controller appears to be damaged contact the Fujitsu support service Step 2 Prepare the server Turn off the server and remove the cover from the...

Page 42: ...bove see your system board guide for information on the PCIe slot Press down gently but firmly to ensure the card is properly seated in the slot Secure the controller to the server chassis with the PCI card hold down latches Connect the SAS and or SATA HDDs located in the system to the SAS cable connector s on the controller Edge of Motherboard Edge of Motherboard Press Here Press Here ...

Page 43: ...e WebBIOS Configuration Utility to configure the physical arrays and logical drives Press CTRL H immediately to run the utility when the following message appears on the screen Press Ctrl H for WebBIOS Step 6 Install the operating system driver The controller can operate under various operating systems To use these operating systems you must install software drivers The ServerView Suite DVD 1 incl...

Page 44: ...IiBBU07 LSIiBBU08 supports remote connection to the Modular RAID Controller RAID Ctrl SAS 6G 5 6 512 MB D2616 The LSIiBBU07 LSIiBBU08 is not installed directly on the RAID controller Instead use one of the supplied cables to connect the LSIiBBU07 LSIiBBU08 to the RAID controller The battery backup unit must be mounted inside the chassis I Because server chassis vary there is no standard mounting o...

Page 45: ...d yourself then remove the LSIiBBU07 LSIiBBU08 from its package 2 Secure the LSIiBBU07 LSIiBBU08 to the server chassis as described in the server documentation 3 Insert the battery pack harness connector at the end of the colored wires into the J4 connector see figure 13 on the bottom of the LSIiBBU07 LSIiBBU08 4 Connect the cable from the cable connector see figure 13 on the LSIiBBU07 LSIiBBU08 t...

Page 46: ...46 Modular RAID Controllers Modular RAID 6Gb s SAS2 0 Figure 14 Installing the iBBU07 iBBU08 in a server chassis PIN1 Edge of Motherboard Edge of Motherboard ...

Page 47: ...rtant information on page 9 The RAID controller PY SAS RAID Mezz Card 6 Gb D3016 is designed to drive the BX400 and BX900 server s internal or external disk drives The RAID stack is based on LSI MegaRAID and offers powerful data throughput extensive fault tolerance and easy to use management Figure 15 PY SAS RAID Mezz Card 6 Gb D3016 with optional iBBU based on LSI SAS2108 ...

Page 48: ...llowing STP features Addressing of SATA targets through expander Native Command Queuing NCQ Support of the following SSP features Wide port functionality 2 or 4 Phys from a single quad port Narrow port functionality 1 Phy Compatible with SATA target devices 2 x SATA connectors for internal hard disk drives 1 x SAS lane each 1 x Midplane connector 4 x SAS lanes Hot plug drives SGPIO interfaces for ...

Page 49: ...ular RAID 6Gb s SAS2 0 4 3 3 Connectors and indicators The following figure shows the location of the connectors and indicators on the SAS RAID controller 1 iBBU 4 LED 2 SAS cable connectors 5 iBBU connector 3 SDB connector 1 2 3 4 5 ...

Page 50: ...ocal SAS SATA hard disk drives SAS1 x1 SAS1 SATA connectors to connect local SAS SATA hard disk drives SDB SAS side band signals 6 pin connector SAS side band connector BBU Connector for direct iBBU connection LED Description HB Heart Beat WP Write in cache pending WA Warning Step 1 Unpack the controller Unpack the new controller in a static free environment Remove it from the anti static bag and ...

Page 51: ...6 FW package xxxx Step 5 Run the WebBIOS Configuration Utility Run the WebBIOS Configuration Utility to configure the physical arrays and logical drives Press CTRL H immediately to run the utility when the following message appears on the screen Press Ctrl H for WebBIOS Step 6 Install the operating system driver The controller can operate under various operating systems To use these operating syst...

Page 52: ... The capabilities of the LSIiBBU08 include monitoring the battery status and power levels as well as the ability to recondition and calibrate the battery for improved reliability It maintains data in the cache in the case of powerfail see data sheet for hold time duration 4 3 5 2 Installation The LSIiBBU08 supports board to board connection to the modular RAID controller PY SAS RAID Mezz Card 6 Gb...

Page 53: ...screws that attach the LSIiBBU08 to the RAID Mezz Card To install the LSIiBBU08 to the RAID controller proceed as follows 1 Ground yourself then remove the LSIiBBU08 from its package 2 Align iBBU08 connector J1 with iBBU connector of RAID Mezz Card and fix the iBBU08 as described in the server documentation 1 2 2 2 ...

Page 54: ... Ctrl SAS 6G 1GB D3116 is designed to drive the server s internal disk drives The RAID stack is based on LSI MegaRAID and offers powerful data throughput extensive fault tolerance and easy to use management Figure 16 RAID Ctrl SAS 6G 1GB D3116 controller based on LSI SAS2208 I Depending on the target system the following bracket types are offered Full height perforated Full height not perforated L...

Page 55: ...lane 5 0 8 0 Gbit PCIe host bus 8 SAS SATA ports Each SAS SATA port supports SSP SMP and STP Support for the following STP features Addressing of SATA targets through expander Native Command Queuing NCQ Support of the following SSP features Wide port functionality 2 or 4 Phys from a single quad port or or 8 Phys over two quad ports Narrow port functionality 1 Phy Compatible with SATA target device...

Page 56: ...connectors and indicators on the SAS RAID controller Name Chip PCIe Cache No of SAS channels Bracket type S26361 D3116 Bx LSI SAS2208 PCIe 2 0 1 GB 8 low profile full height S26361 D3116 Cx LSI SAS2208 PCIe 3 0 1 GB 8 low profile full height 1 HDD LED connector 4 FBU connector on TFM 2 TFM indicator LEDs 5 Indicator LEDs 3 TFM optional 6 SAS cable connectors ...

Page 57: ...ckplane and HDDs SAS MLC2 x4 SAS ports 4 7 SFF 8087 Mini SAS connector for SAS IO cable to backplane and HDDs HDD LED HDD activity indication LED 6 pin connector Pin 4 to connect activity LED FBU 1 6 Connector on TFM to attach FBU LED Description L1 HB Heart Beat L2 SE0 Error for Power PC0 L3 SE1 Error for Power PC1 LED Description L1 green Power available L2 blue TFM FBU status L3 yellow Cache of...

Page 58: ...f the controller appears to be damaged contact the Fujitsu support service Step 2 Prepare the server Turn off the server and remove the cover from the chassis Step 3 Install the new SAS RAID controller Insert the controller in a suitable PCIe slot on the system board Press down gently but firmly to ensure the controller is properly seated in the slot Secure the controller to the server chassis wit...

Page 59: ...ebBIOS Configuration Utility to configure the physical arrays and logical drives Press CTRL H immediately to run the utility when the following message appears on the screen Press Ctrl H for WebBIOS Step 6 Install the operating system driver The controller can operate under various operating systems To use these operating systems you must install software drivers The ServerView Suite DVD 1 include...

Page 60: ...l battery backup unit after a limited time without restored power the cached data is lost However CacheVault technology safely stores the contents of DRAM on NAND flash for up to three years 4 4 5 2 Installation The FBU supports remote connection to the Modular RAID Controller RAID Ctrl SAS 6G 1GB D3116 The FBU is not installed directly on the RAID controller Instead use one of the supplied cables...

Page 61: ...connecting the FBU from to the TFM remove AC power from your system To install the TFM and FBU proceed as follows Figure 17 Installing the TFM Ê Ground yourself then fit the spacer bolts on the TFM on SAS RAID controller 1 Ê Secure the TFM on the controller with the three screws from the TFM kit 2 Ê Remove the FBU from its package ...

Page 62: ...own 1 Push in the FBU until it locks in place 2 Figure 19 Connecting the FBU adapter cable to the FBU Ê Connect the cable end of the FBU cable to the FBU adapter cable as shown Ê Secure the FBU to the server chassis as described in the server documentation Ê Connect the loose end of the FBU adapter cable to the TFM on the RAID controller see section Connectors and indicators on page 56 ...

Page 63: ... Important information on page 9 The RAID controller PY SAS RAID HDD Module D2816 is designed to drive the BX920 server s internal or BX400 BX900 external disk drives The RAID stack is based on LSI MegaRAID and offers powerful data throughput extensive fault tolerance and easy to use management Figure 20 PY SAS RAID HDD Module D2816 controller based on LSI SAS2208 ...

Page 64: ...CIe host bus 6 SAS SATA ports 2 2 ports for Storage Blade Connection and 2 ports for Blade internal HDD Connection Each SAS SATA port supports SSP SMP and STP Support for the following STP features Addressing of SATA targets through expander Native Command Queuing NCQ Support of the following SSP features Wide port functionality 2x2 Phys from a single quad port Narrow port functionality 1 Phy Comp...

Page 65: ...icators on the SAS RAID controller Name Chip PCIe Cache No of SAS channels S26361 D2816 Ax LSI SAS2208 PCIe 2 0 512 MB 2 2 ports for Storage Blade Connection 2 ports for Blade internal HDD Connection S26361 D2816 Cx LSI SAS2208 PCIe 3 0 512 MB 2 2 ports for Storage Blade Connection 2 ports for Blade internal HDD Connection 1 FBU connector 3 Indicator LEDs 2 TFM indicator LEDs ...

Page 66: ...ription L1 H322 Heart Beat L2 H321 Error for Power PC1 L3 H320 Error for Power PC0 L4 H102 Power available L5 H101 Status L6 H100 Cache offload fault Step 1 Unpack the controller Unpack the new controller in a static free environment Remove it from the anti static bag and inspect it for damage If the controller appears to be damaged contact the Fujitsu support service Step 2 Prepare the server Shu...

Page 67: ...un the WebBIOS Configuration Utility to configure the physical arrays and logical drives Press CTRL H immediately to run the utility when the following message appears on the screen Press Ctrl H for WebBIOS Step 6 Install the operating system driver The controller can operate under various operating systems To use these operating systems you must install software drivers The ServerView Suite DVD 1...

Page 68: ...technology offers CacheVault technology transfers the contents of the DRAM cache to NAND flash using power from the supercap module in the event of a power or server failure With a traditional battery backup unit after a limited time without restored power the cached data is lost However CacheVault technology safely stores the contents of DRAM on NAND flash for up to three years 4 5 5 2 Installati...

Page 69: ...llers 69 Modular RAID 6Gb s SAS2 0 Figure 21 LSI FBU02A module Ê Install the FBU into the system and connect it to the SAS RAID controller as described in the PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual ...

Page 70: ...chapter Important information on page 9 The RAID controller PY SAS RAID HDD Module w o Cache D2837 is designed to drive the BX400 and BX900 server s internal disk drives The RAID stack is based on LSI MegaRAID and offers powerful data throughput extensive fault tolerance and easy to use management Figure 22 PY SAS RAID HDD Module w o Cache D2837 based on LSI SAS2208 ...

Page 71: ... Support for the following STP features Addressing of SATA targets through expander Native Command Queuing NCQ Support of the following SSP features Wide port functionality 2x2 Phys from a single quad port Narrow port functionality 1 Phy Compatible with SATA target devices SGPIO interfaces for signaling of SAS SATA ports Drive spin up sequencing control Hot plug drives 1 5 Gbit s 3 0 Gbit s and 6 ...

Page 72: ...SAS2 0 4 6 3 Connectors and indicators The following figure shows the location of the connectors and indicators on the SAS controller Indicators 1 Indicators LED Description L1 H322 Heart Beat L2 H321 Error for Power PC1 L3 H320 Error for Power PC0 ...

Page 73: ...d contact the Fujitsu support service Step 2 Prepare the server Shut down and power off the server and remove the server blade from the chassis Step 3 Install the new SAS RAID controller Refer to the server blade specific Options Guide or Upgrade and Maintenance Manual Step 4 Power up the server Replace the server cover and reinstall the server blade to the chassis Start up the server Ensure that ...

Page 74: ...tep 6 Install the operating system driver The controller can operate under various operating systems To use these operating systems you must install software drivers The ServerView Suite DVD 1 includes drivers for the supported operating systems along with documentation You can view the supported operating systems and download the latest drivers for RAID adapters on the website at http ts fujitsu ...

Page 75: ...er PRAID EP400i EP420i D3216 is designed to drive the server s internal disk drives The RAID stack is based on LSI MegaRAID and offers powerful data throughput extensive fault tolerance and easy to use management Figure 23 PRAID EP400i EP420i based on LSI SAS3108 I Depending on the target system the following bracket types are offered Full height perforated Full height not perforated Low profile p...

Page 76: ...tions Provides a full featured hardware based RAID solution that supports RAID levels 0 1 1E 5 6 10 50 and 60 Six I2 C interfaces used for Serial Boot strap ROM connection memory detection PCI E SMBus connectivity battery smart charger control and SAS sideband control Integrated dual UART for MegaRAID diagnostic use only Two banks of SGPIO signals to accompany the two sets of x4 SAS SATA ports 16M...

Page 77: ...ors and indicators The following figure shows the location of the connectors and indicators on the SAS RAID controller Figure 24 PRAID EP400i EP420i board layout 1 SAS cable connectors 2 TFM optional 3 FBU connector on TFM 4 HDD LED connector 5 RAID controller indicator ...

Page 78: ...nector for SAS IO cable to backplane and HDDs SAS MLC2 x4 SAS ports 4 7 SFF 8643 Mini SAS HD 4i connector for SAS IO cable to backplane and HDDs HDD LED HDD activity indication LED 6 pin connector Pin 4 to connect activity LED FBU 1 6 Connector on TFM to attach FBU LED Description L1 green blinking Heart Beat Step 1 Unpack the controller Unpack the new controller in a static free environment Remov...

Page 79: ...ge similar to the following is displayed LSI MegaRAID SAS MFI BIOS Version NTxx Build date Copyright c 2014 LSI Corporation HA x Bus x Dev y PRAID EP400i EP420i D3216 FW package xxxx Step 5 Run the BIOS Configuration Utility Run the BIOS Configuration Utility to configure the physical arrays and logical drives Press CTRL R immediately to run the utility when the following message appears on the sc...

Page 80: ...traditional battery backup unit after a limited time without restored power the cached data is lost However CacheVault technology safely stores the contents of DRAM on NAND flash for up to three years 5 1 5 2 Installation The FBU supports remote connection to the Modular RAID Controller PRAID EP400i EP420i The FBU is not installed directly on the RAID controller Instead use one of the supplied cab...

Page 81: ...AC power from your system I Depending on the controller cache size two different TFM kits are available Installing the TFM Figure 25 Installing the TFM A Ê Ground yourself then fit the two spacer bolts on the controller Name Cache TFM kit PRAID EP400i S26361 D3216 Axx 1 GB PRAID EP400i TFM LSZ 03 25444 05 PRAID EP420i S26361 D3216 Bxx 2 GB PRAID EP420i TFM LSZ 03 25444 01 ...

Page 82: ...82 Modular RAID Controllers Modular RAID 12Gb s SAS3 0 Figure 26 Installing the TFM B Ê Secure the PRAID EP400i EP420i TFM on the controller with the two screws from the TFM kit ...

Page 83: ...BU can be different depending on your server Refer to your server s Upgrade and Maintenance Manual for mounting details Ê Remove the FBU from its package Figure 27 Installing the FBU in the FBU holder Ê At a slight angle fit the FBU under both retaining brackets of the FBU holder as shown Push in the FBU until it locks in place ...

Page 84: ... the FBU cable to the FBU adapter cable as shown Ê Secure the FBU to the server chassis as described in the server documentation Connecting the FBU adapter cable Figure 29 Connecting the FBU adapter cable Ê Connect the loose end of the FBU adapter cable to the TFM on the RAID controller see section Connectors and indicators on page 77 ...

Page 85: ...C with 72 bit DDRIII interface that drives 1GB cache memory It supports 1 5Gb s 3 0Gb s 6 0Gb s and 12Gb s SAS SATA and solid state drives SSDs with different RAID levels It includes onboard flash for performing DDR3 SDRAM cache offload function to protect data cache in case of host power failure Furthermore it includes monitoring and control circuitry for the remotely located SuperCap Module as w...

Page 86: ...ations Provides a full featured hardware based RAID solution that supports RAID levels 0 1 5 6 10 50 and 60 Six I2 C interfaces used for Serial Boot strap ROM connection memory detection PCI E SMBus connectivity battery smart charger control and SAS sideband control Integrated dual UART for MegaRAID diagnostic use only Two banks of SGPIO signals to accompany the two sets of x4 SAS SATA ports 16MB ...

Page 87: ... following figure shows the location of the connectors and indicators on the SAS RAID controller Figure 31 PRAID EM400i board layout 1 HSEC8 connector for PCIe 2 UART connector 3 SuperCap Module connector 4 Indicators 5 2x SAS connectors port 0 1 6 SAS connector port 4 7 H100 H101 H322 H102 ...

Page 88: ...D One surface mounted BLUE LED H101 indicates activity on ONFI interface When LED is on it indicates that either Cache Offload from DDR3 memory to NAND Flash or Restore Operation from NAND flash to DDR3 memory is in progress H102 green Power LED One surface mounted GREEN LED H102 indicates the status of back up Power When LED is on it indicates that SuperCap backup Power is enabled and SuperCap is...

Page 89: ...W package xxxx Step 5 Run the BIOS Configuration Utility Run the BIOS Configuration Utility to configure the physical arrays and logical drives Press CTRL R immediately to run the utility when the following message appears on the screen Press Ctrl R to Run MegaRAID Configuration Utility Step 6 Install the operating system driver The controller can operate under various operating systems To use the...

Page 90: ...8 to 8 port SAS SATA bridge built on the LSI SAS3108 dual core It supports 1 5Gb s 3 0Gb s 6 0Gb s and 12Gb s SAS SATA and solid state drives SSDs with different RAID levels The MPI solution offered with this design includes a basic integrated RAID IR capability consisting of RAID 0 1 and 1E provided at no charge beyond the silicon cost IR operation requires no Cache but does require a small non v...

Page 91: ...vides a 40 bit or a 72 bit 1866 MHz DDR3 SDRAM interface with a hardware RAID assist engine for parity calculations Six I2 C interfaces used for Serial Boot strap ROM connection memory detection PCI E SMBus connectivity battery smart charger control and SAS sideband control Integrated dual UART for MegaRAID diagnostic use only Two banks of SGPIO signals to accompany the two sets of x4 SAS SATA por...

Page 92: ...The following figure shows the location of the connectors and indicators on the SAS RAID controller Figure 33 PRAID CM400i board layout 1 HSEC8 connector for PCIe 2 UART connector 3 SuperCap Module connector 4 Indicator H322 Heart Beat 5 2x SAS connectors port 0 1 6 SAS connector port 4 7 ...

Page 93: ...anti static bag and inspect it for damage If the controller appears to be damaged contact the Fujitsu support service Step 2 Prepare the server Shut down and power off the server Step 3 Install the new SAS RAID controller Refer to your server specific Upgrade and Maintenance Manual for information on the PCIe slot and installing the controller Step 4 Power up the server Start up the server Ensure ...

Page 94: ... Utility Step 6 Install the operating system driver The controller can operate under various operating systems To use these operating systems you must install software drivers The ServerView Suite DVD 1 includes drivers for the supported operating systems along with documentation You can view the supported operating systems and download the latest drivers for RAID adapters on the website at http t...

Page 95: ... controller PRAID CP400i D3307 is a dual PHY SAS PCIe RAID controller and is used in a system with a PCIe slot PCIe goes beyond the PCI specification in that it is intended as a unifying I O architecture for various systems Figure 34 PRAID CP400i I Depending on the target system the following bracket types are offered Full height perforated Full height not perforated Low profile perforated ...

Page 96: ...ort 12Gb s SAS3 and 6Gb s SATA interface Six I2C interfaces used for Serial Boot strap ROM connection PCI E SMBus connectivity and SAS sideband control Integrated dual UART for MegaRAID diagnostic use only Two banks of SGPIO signals to accompany the two sets of x4 SAS SATA ports 16MB Flash 1kB Bootstrap EEPROM Raid key chip onboard Provides a full featured hardware based RAID solution that support...

Page 97: ...35 PRAID CP400i board layout Connectors 1 HDD LED connector 2 Indicators 3 SAS connectors Connector Type Description SAS MLC1 x4 SAS ports 0 3 SFF 8643 Mini SAS HD 4i connector for SAS IO cable to backplane and HDDs SAS MLC2 x4 SAS ports 4 7 SFF 8643 Mini SAS HD 4i connector for SAS IO cable to backplane and HDDs HDD LED HDD activity indication LED 6 pin connector Pin 4 to connect activity LED ...

Page 98: ...anti static bag and inspect it for damage If the controller appears to be damaged contact the Fujitsu support service Step 2 Prepare the server Shut down and power off the server Step 3 Install the new SAS RAID controller Refer to your server specific Upgrade and Maintenance Manual for information on the PCIe slot and installing the controller Step 4 Power up the server Start up the server Ensure ...

Page 99: ... Utility Step 6 Install the operating system driver The controller can operate under various operating systems To use these operating systems you must install software drivers The ServerView Suite DVD 1 includes drivers for the supported operating systems along with documentation You can view the supported operating systems and download the latest drivers for RAID adapters on the website at http t...

Page 100: ...afety notes in chapter Important information on page 9 The RAID controller PRAID EP420e brings 12Gb s Serial Attached SCSI and 6Gb s SATA III performance to workstation and server designs Figure 36 PRAID EP420e I Depending on the target system the following bracket types are offered Full height perforated Low profile perforated ...

Page 101: ... PCIe x8 lane width PCIe 3 0 performance up to 8Gb s per lane Support for 2 GB DDR3 at 1866 MHz with ONFI cache offload support Two external connectors Support for RAID levels 0 1 5 6 10 50 and 60 Advanced array configuration and management utilities Support for global hot spares and dedicated hot spares Support for user defined strip sizes 64 KB 128 KB 256 KB 512 KB or 1024 KB Mounting holes for ...

Page 102: ...The following TFM kit is available Figure 37 PRAID EP420e with installed TFM Name Chip PCIe No ofSAS channels Bracket type PRAID EP420e LSI SAS3108 PCIe 3 0 8 low profile full height Name Cache TFM kit PRAID EP420e 2 GB PRAID EP420i TFM LSZ 03 25444 01 1 Connector for FBU adapter cable ...

Page 103: ... LED1 connector 2 HDD LED2 connector 3 CacheVault Flash Module ONFI interface 4 Cache write pending connector 5 Two SAS connectors Connector Type Description HDD LED1 Global hard disk drive HDD activity 2 pin connector Connects to an LED that indicates activity on the drives connected to the controller HDD LED2 Global drive fault LED 2 pin connector Connects to an LED that indicates activity on th...

Page 104: ...NFI interface 80 pin connector Connects the RAID controller to a TFM optional Cache write pending connector 2 pin connector Connector for an LED mounted on the system enclosure The LED indicates that the data in the cache has yet to be written to the storage devices SAS MLC1 x4 SAS ports 0 3 SFF 8644 Mini SAS HD 4e connector for SAS IO cable to backplane and HDDs SAS MLC2 x4 SAS ports 4 7 SFF 8644...

Page 105: ... a message similar to the following is displayed LSI MegaRAID SAS MFI BIOS Version NTxx Build date Copyright c 2014 LSI Corporation HA x Bus x Dev y PRAID EP420e Dnnnn FW package xxxx Step 5 Run the BIOS Configuration Utility Run the BIOS Configuration Utility to configure the physical arrays and logical drives Press CTRL R immediately to run the utility when the following message appears on the s...

Page 106: ...with the same TFM as for PRAID EP420i Please proceed in the same way as described in section Installing an optional TFM FBU on page 80 I The FBU type the FBU mounting position and the FBU adapter cable may be different for your server Please refer to your server specific Upgrade and Maintenance Manual for detailed information ...

Page 107: ...on on page 9 The RAID controller PRAID EP440i is designed to drive the server s internal disk drives The RAID stack is based on LSI MegaRAID and offers powerful data throughput extensive fault tolerance and easy to use management Figure 39 PRAID EP440i I Depending on the target system the following bracket types are offered Full height perforated Low profile perforated ...

Page 108: ...d 6Gb s SATA3 interface Provides a 1866 MHz DDR3 SDRAM interface with a hardware RAID assist engine for parity calculations Provides a full featured hardware based RAID solution that supports RAID levels 0 1 1E 5 6 10 50 and 60 Six I2 C interfaces used for Serial Boot strap ROM connection memory detection PCI E SMBus connectivity battery smart charger control and SAS sideband control Integrated du...

Page 109: ...lowing figure shows the location of the connectors on the SAS RAID controller Figure 40 PRAID EP440i board layout Name Chip PCIe Cache No ofSAS channels Bracket type PRAID EP440i LSI SAS3108 PCIe 3 0 4 GB 8 low profile full height 1 Global Drive Activity LED connector 2 SAS cable connectors 3 assembled TFM ...

Page 110: ...l Drive Activity LED cable To activate the HDD activity indicator at the front of the system a cable must be connected to the Global Drive Activity LED connector of the RAID controller PRAID EP440i see figure 40 Figure 41 Connecting the Global Drive Activity LED cable variant 1 ...

Page 111: ...e Activity LED cable variant 2 Ê Connect the 2 pin connector 2 of the Global Drive Activity LED cable with the marking plugged to pin 1 Ê Connect the 4 pin connector 1 of the Global Drive Activity LED cable to the system board Please refer to the system specific manual to locate the connector ...

Page 112: ...If the controller appears to be damaged contact the Fujitsu support service Step 2 Prepare the server Turn off the server and remove the cover from the chassis Step 3 Install the new SAS RAID controller Insert the controller in a suitable PCIe slot on the system board Press down gently but firmly to ensure the controller is properly seated in the slot Secure the controller to the server chassis wi...

Page 113: ...ity to configure the physical arrays and logical drives Press CTRL R immediately to run the utility when the following message appears on the screen Press Ctrl R to Run MegaRAID Configuration Utility Step 6 Install the operating system driver The controller can operate under various operating systems To use these operating systems you must install software drivers The ServerView Suite DVD 1 includ...

Page 114: ...ter a limited time without restored power the cached data is lost However CacheVault technology safely stores the contents of DRAM on NAND flash for up to three years 5 6 5 2 Installation The FBU supports remote connection to the RAID controller PRAID EP440i The FBU is not installed directly on the RAID controller Instead use one of the supplied cables to connect the FBU to the TFM on the RAID con...

Page 115: ...BU can be different depending on your server Refer to your server s Upgrade and Maintenance Manual for mounting details Ê Remove the FBU from its package Figure 43 Installing the FBU in the FBU holder Ê At a slight angle fit the FBU under both retaining brackets of the FBU holder as shown Push in the FBU until it locks in place ...

Page 116: ...e end of the FBU cable to the FBU adapter cable as shown Ê Secure the FBU to the server chassis as described in the server documentation Connecting the FBU adapter cable Figure 45 Connecting the FBU adapter cable Ê Connect the loose end of the FBU adapter cable to the TFM on the RAID controller see section Connectors on page 109 ...