background image

D2532 (RX100 S4)

 

9

Important notes

Notes on safety

Modules with electrostatic-sensitive components

Systems and components that might be damaged by electrostatic discharge 
(ESD) are marked with the following label:

Figure 1: ESD label

When you handle components fitted with ESDs, you must observe the following 
points under all circumstances:

You must always discharge yourself of static charges (e.g. by touching a 
grounded object) before working.

The equipment and tools you use must be free of static charges.

Remove the power plug from the power socket before inserting or removing 
boards containing ESDs.

Always hold boards with ESDs by their edges.

Never touch pins or conductors on boards fitted with ESDs.

Use a grounding cable designed for this purpose to connect yourself to the 
system unit as you install/deinstall the board.

Place all components on a static-safe base.

I

You will find a detailed description for handling ESD components in the 
relevant European or international standards (EN 61340-5-1, 
ANSI/ESD S20.20).

Summary of Contents for D2532

Page 1: ...D2532 for RX100 S4 Technical manual Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e mail email manuals fujitsu siemens com Tel 089 61001 155 Fax 49 700 372 00000 D2532 RX100 S4 Sprachen En Edition April 2007 ...

Page 2: ...according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2006 Fujitsu Siemens Computers Gmb...

Page 3: ...10 2 3 Environment Protection 11 3 Features 13 3 1 Overview 13 3 2 Main memory 15 3 3 PCI bus 15 3 4 Screen resolution 16 3 5 Temperature system monitoring 16 3 6 Connectors and jumpers 18 3 6 1 External connectors 21 4 SAS IME configuration program 23 5 Replacing the lithium battery 33 Abbreviations 35 ...

Page 4: ......

Page 5: ...system output on the monitor semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key symbols quotation mar...

Page 6: ......

Page 7: ...ure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packaging or in pa...

Page 8: ...m requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm lightning hazard Batteries V CAUTION Incorrect replacement of lithium battery may lead to a risk of explosion The batt...

Page 9: ... grounded object before working The equipment and tools you use must be free of static charges Remove the power plug from the power socket before inserting or removing boards containing ESDs Always hold boards with ESDs by their edges Never touch pins or conductors on boards fitted with ESDs Use a grounding cable designed for this purpose to connect yourself to the system unit as you install deins...

Page 10: ... insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp objects s...

Page 11: ...til they need to be used and should be switched off during long breaks and on completion of work Notes on packaging Please do not throw away the packaging You may need it later for transporting your system unit If possible the device should only be transported in its original packaging Notes on dealing with consumables Please dispose of printer consumables and batteries in accordance with local go...

Page 12: ...ling center in Paderborn Fujitsu Siemens Computers Recycling Center D 33106 Paderborn Germany Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device may not be disposed of with household rubbish This appliance is labelled in accordance with European Directive 2002 96 EC concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE The guideline determines the fram...

Page 13: ...775 Intel chipset Intel 3000 chipset Southbridge Intel ICH7R PXH V SAS controller LSI 1068 only SAS version On optional riser card 2 x PCI X 64 Bit 133 MHz slots or 1 x PCI Express x8 slot and 1 x PCI X 64 Bit 133 MHz slot Dual Gigabit LAN controller Broadcom 5715 iRMC onboard Server Management and graphic controller Main memory Up to 4 slots for main memory DDR II 533 PC2 4200 SDRAM unbuf fered M...

Page 14: ...rd port 1x mouse port 1x RS 232 C interface serial 9 pin 2x RJ45 LAN ports onboard LAN BIOS features Phoenix BIOS Power on self test System boot possible from CD DVD ROM hard disk LAN USB CMOS setup parameters Shadow RAM BIOS Shadow video BIOS IPMI V2 0 support DMI function support System security Power on Password and Setup Password Form factor 260 mm x 305 mm ...

Page 15: ...o riser cards are available The following tables show an overview of the PCI slots Riser card 1 Riser card 2 Assignment of the PCI interrupts The PCI interrupts are assigned automatically by the BIOS and no further settings are possible PCI bus Signal level Slot no Length PCI E x8 1 1x low profile or standard slot max length 175 mm 64 Bit 133 MHz PCI X 3 3 V 2 1x low profile slot max length 170 mm...

Page 16: ...puter hardware against damage caused by overheating In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The temperature and system monitoring are controlled by an onboard controller The following functions are supported Temperature monitoring Measurement of the processor temperature measurement of the ambient temperature...

Page 17: ... Should this happen all fans monitored by this sensor run at maximum speed to achieve the greatest possible protection of the hardware Voltage monitoring When voltage exceeds warning level high an alert will be generated System Event Log SEL All monitored events of the system board are recorded in the System Event Log ...

Page 18: ...A10 SAS version and S26361 D2532 B10 SATA version Figure 2 Schematic overview of the system board D2532 1 CN26 front panel connector 2 CN17 SAS SATA backplane connector 3 CN25 power connector for CPU 1 CPU DIMM2B DIMM1B DIMM2A DIMM1A JP3 CN26 CN25 IDE 1 CN20 JP1 3 4 5 6 7 8 9 14 13 12 11 10 16 15 17 19 21 22 23 20 CN22 CN19 CN18 CN16 CN13 CN17 CN11 CN15 24 2 18 ...

Page 19: ... IDE 1 connector 10 Mouse keyboard connector 11 VGA COM1 connector 12 Global Error LED Identifications LED 13 LAN 1 connector Server Management LAN 14 LAN 2 connector 15 USB connector 16 USB connector 17 Slot for riser card 18 Battery 19 CN11 SATA BP LED connector 20 SAS SATA 2 connector 21 SAS SATA 1 connector 22 SATA 3 connector only SATA version 23 CN12 PSU I2 C connector 24 CN11 PSU ATX connec...

Page 20: ...with jumpers The system board is supplied with all jumpers set on the following positions Figure 3 Jumper default settings JP1 Boot Block JP3 Password Skip 1 2 Normal boot default 2 3 BIOS recovery 1 2 Disable default 2 3 Enable JP3 CN26 CN25 JP1 CN13 CN17 CN15 ...

Page 21: ...ly LAN port 1 can be exclusive for management or be shared with the standard OS LAN connectors On this system board you will find the dual Gigabit LAN controller Broadcom 5715 This LAN controller supports the transfer rates of 10 Mbit s 100 Mbit s and 1 Gbit s The LAN controller supports WOL function through Magic Packet It is also possible to boot a device without its own boot hard disk via LAN H...

Page 22: ...th two LEDs light emitting diode indicating the transfer rate and the activity Figure 5 LAN connector 1 LAN link aktivity green on LAN connection off no LAN connection flashing LAN transfer 2 LAN transfer rate off transfer rate 10 Mbit s or no connection green on transfer rate 100 Mbit s yellow on transfer rate 1000 Mbit s 1 2 ...

Page 23: ... configuration program This program allows you to change almost all of the option settings of the SAS controller When you boot the system a SAS BIOS message listing the SAS devices connected is displayed I If a SAS BIOS error message appears or problems arise with SAS devices please read the documentation of your SAS device If you are unable to trace or rectify the error please contact your dealer...

Page 24: ... available SAS controllers are displayed LSI Logic MPT Setup Utility Adapter List Global Properties ____________________________________________________________________________ Adapter PCI PCI PCI PCI FW Revision Status Boot Bus Dev FNC Slot Order SAS1068 02 08 00 00 1 10 01 00 IR Enabled 0 ____________________________________________________________________________ Esc Exit Menu F1 Shift 1 Help A...

Page 25: ...__________________________________________________________________________ Adapter Properties SAS1068 PCI Slot 00 PCI Address Bus dev Func 02 08 00 MPT Firmware Revision 1 10 01 00 IR SAS Address 5003005F FFFFFFF0 Status Enabled Boot Order 0 Boot Support Enabled BIOS OS RAID Properties SAS Topology Advanced Adapter Properties ________________________________________________________________________...

Page 26: ... Create Integrated Mirror Array of 2 disks plus an optional hot spare Data on the primary disk may be migrated Create IME Volume Create Integrated Mirrored Enhanced Array of 3 to 8 disks including an optional hot spare ALL DATA on array disks will be DELETED Create IS Volume Create Integrated array of 2 to 8 disks ALL DATA on array disks will be DELETED ____________________________________________...

Page 27: ...l Manage Array Slot Device Identifier RAID Hot Drive Pred Size Num Disk Spr Status Fail MB 4 SEAGATE ST373454SS 1501 Yes No Primary No 34332 5 SEAGATE ST3146854SS 1501 Yes No Secondary No 34332 ______________________________________________________________________________ Esc Exit Menu F1 Shift 1 Help Enter Select Item Alt N Next Array C Create an array I Only two RAIDs can be configured on the SA...

Page 28: ...e SAS1068 02 08 00 Info I_ Enclosure Direct Attach Devices Controller I_ Bay 0 SEAGATE ST3146854SS 1501 SAS I_ Bay 1 SEAGATE ST336754SS 1501 SAS I_ Bay 2 SEAGATE ST336754SS 1501 SAS I_ Bay 4 RAID Physical Disk SAS I_ Bay 5 RAID Physical Disk SAS I_ IM VOL LSILOGICLogical Volume 3000 I_ SEAGATE ST373454SS 1501 I_ SEAGATE ST3146854SS 1501 _____________________________________________________________...

Page 29: ... 01 CHS Mapping SCSI Plug and Play Mapping Advanced Device Properties Spinup Properties PHY Properties Restore Defaults ______________________________________________________________________________ Esc Exit Menu F1 Shift 1 Help Enter Select Item Change Item CHS Mapping SCSI Plug and Play Mapping it is recommended don t change this setting or Alternate CHS Mapping Menu Advanced Device Properties s...

Page 30: ...is adapter 24 IO Timeout for Block Devices 10 IO Timeout for Block Devices Removable 10 IO Timeout for Sequential Devices 10 IO Timeout for Other Devices 10 LUNs to Scan for Block Devices All LUNs to Scan for Block Devices Removable All LUNs to Scan for Sequential Devices All LUNs to Scan for Other Devices All Removable Media support None Restore Defaults __________________________________________...

Page 31: ...Target devices to Spinup 0 ______________________________________________________________________________ Esc Exit Menu F1 Shift 1 Help Spinup Delay Defines the intervals for the spinup of the hard disks The default setting is 2 When this feature is enabled the SAS devices which support this function are not started by switching on the server until they receive a Start Unit command from BIOS of th...

Page 32: ...________________________________________ PHY 0 1st of 8 PHYs SAS Port 0 Link Status Enabled 3 0 Gbps Discovery Status 000000 Device Identifier SEAGATE ST3146854SS 1501 Scan Order 0 Device Information SAS SAS Address 5000C500 0000EB39 ______________________________________________________________________________ Esc Exit Menu F1 Shift 1 Help Enter Reset Phy error logs Alt N Next Phy Alt P Previous ...

Page 33: ...cal battery or a battery type recommended by the manufacturer CR2032 Do not throw lithium batteries into the trashcan It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 6 Replacing the lithium battery holder is similar Ê Press the locking spring into direction of of t...

Page 34: ......

Page 35: ... valid for the described system board AC Alternating Current ACPI Advanced Configuration and Power management Interface ANSI American National Standards Institute ASR R Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port...

Page 36: ...C Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EFI Extensible Firmware Interface EGB Elektrostatisch gefährdete Bauteile EMI Electromagnetic interference EMRL Embedded RAID Logic EMV Elektromagnetische Verträglichkeit electromagnetic compatibility EPROM Erasable Programmable Read Only Memory ESD ElectroStatic Discharge elektrostatische Entladung ...

Page 37: ...cuit Emulation IDE Integrated intelligent Drive Electronics IEC International Electrotechnical Commission IME Integrated Mirroring Enhanced IOOP Intelligent Organisation Of PCI IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller ISO International Organisation for Standardisation ...

Page 38: ...Maskable Interrupt OEM Original Equipment Manufacturer OHCI Open Host Controller Interface OS Operating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analyzing PIO Programmed Input Output PDB Power Distribution Board PLD Programmable Logic Device PS U Power Supply Unit PWM Pulse Wide Modulation ...

Page 39: ...stances Waste from Electric and Electronic Equipment EU Directive RoMB RAID on Motherboard RSB Remote Service Board RST ReSeT RTC Real Time Clock SAS Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SEL System Event Log SHDG Server Hardware Design Guide ...

Page 40: ...SMP Symmetrical Multi Processing UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WEEE Waste from Electric and Electronic Equipment EU Directive WfM Wired for Management WOL Wake up On LAN ...

Page 41: ...0 S4 Technical manual D2532 RX100 S4 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 Munich Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com ...

Page 42: ......

Page 43: ...0 S4 Technical manual D2532 RX100 S4 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 Munich Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com ...

Page 44: ......

Page 45: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Reviews: