background image

S PLIT TYPE

AIR CONDITIONER

CASSETTE

type (

6

0Hz)

Models

Indoor unit

Outdoor unit

AUU36RC
AUU42RC

AOU42RC

AOU36RC

Summary of Contents for AUU36RC

Page 1: ...S PLIT TYPE AIR CONDITIONER CASSETTE type 60Hz Models Indoor unit Outdoor unit AUU36RC AUU42RC AOU42RC AOU36RC ...

Page 2: ... 790 AIR CIRCULATION H INDOOR m3 h 1000 1700 1012 1720 OUTDOOR 3470 DIMENSIONS IN 11 21 32 x 32 5 8 x32 5 8 NET GRILLE 1 3 8 x 37 x 37 H x W x D mm OUT 45 11 32 x 37 x 14 9 16 WEIGHT NET GROSS IN 88 117 OUT 220 251 100 114 243 273 110 124 MAX PIPE LENGTH HEIGHT ft m 164 99 REMOTE CONTROLLER TYPE WIRED TYPE Hermetic type Permanent Split Condenser 2 pole Single phase Induction motor CODE ZR40K3 PFV ...

Page 3: ...40mm 29 17 32 750mm 29 17 32 750mm 11 21 32 296mm 2 3 8 60mm Drain pipe I D 32mm 298 5mm 11 3 4 250mm 9 27 32 305 5mm 12 248 5mm 9 25 32 4 23 32 120mm 5 29 32 150mm 3 5 8 92mm 2 3 8 60mm 12 305 5mm 11 3 4 298 5mm 9 25 32 248 5mm 4 23 32 120mm 5 29 32 150mm 5 127mm 11 7 32 285mm Drain pipe I D 32mm ...

Page 4: ...C I R C U I T D I A G R A M Models AUU36RC AUU42RC Model AOU36RC ...

Page 5: ...Model AOU42RC ...

Page 6: ...Y S T E M D I A G R A M Refrigerant pipe ø 19 05mm 3 4 Refrigerant pipe ø 9 53mm 3 8 COOL HEAT Charging valve Muffler Compressor 4 way valve Accumulator Charging valve Dryer Expansion valve Strainer OUTDOOR UNIT INDOOR UNIT Evaporator Condenser High pressure switch ...

Page 7: ...Outdoor heat exchanger temperature sensor open Outdoor heat exchanger temperature sensor shortcircuited Power source connection error Float switch operated Outdoor temperature sensor open Outdoor temperature sensor shortcircuited Discharge pipe temperature sensor open Discharge pipe temperature sensor shortcircuited Outdoor high pressure abnormal Discharge pipe temperature abnormal Model abnormal ...

Page 8: ... 41 40 39 P64 P65 P65 P66 P47 25 43 53 57 P04 RESET AN2 33 P56 45 15 I NTP1 BUZ 13 12 11 10 P31 P32 P33 P34 9 P30 P03 47 44 I NTP0 34 P57 20 19 18 21 22 23 24 P46 P44 P45 P43 P40 P41 P42 46 I NTP2 14V NC IC 1 7 uPA2003GR 13 4 12 5 C 1 2 4 8 NO1 NO2 NO3 ZONE CONTROL SWITCHING ROOM TEMPERATURE CORRECTION HEATING OPERATION ROOM TEMPERATURE CORRECTION HEATING OPERATION CN6 1 CN6 2 UL1015 AWG22 BLACK U...

Page 9: ...AN202K C44 0 1 F C41 C40 C39 C38 0 01 F x 4 0 01 F x 4 C54 C51 C52 C53 5V C43 0 1 F IC6 PST 600C 5V 1 3 2 5V C42 0 1 F R26 1 0K 1 10W 5V 10K 1 10W x 4 R47 R51 R52 R76 R80 1 0K 1 10W R77 1 0K 1 10W R78 1 0K 1 10W R79 1 0K 1 10W R37 R38 R39 R43 10K 1 10W x 4 R30 R31 R33 R32 1 0K 1 10W x 4 R11 R12 R13 1 0K 1 10W x 3 SW1 DSS804 1 2 3 4 5 6 7 8 CN14 B5P SHF 1AA CN14 1 CN14 5 CN14 4 CN14 3 CN14 2 TEST 5...

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ...odel AOY36ACG3L 39 39 41 45 45 817 405 809 810 48 55 18 259 29 185 816 819 806 821 820 109 111 818 334 107 108 12 20 788 16 361 808 21 15 826 807 26 646 790 19 620 54 333 2 178 2 320 1 844 Model AOU36RC ...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...nforcement T A 9362738002 9362738002 472 2 Grille Reinforcement T B 9362739009 9362739009 472 3 Grille Reinforcement T C 9362740005 9362740005 472 4 Grille Reinforcement T D 9362741002 9362741002 472 5 Grille Reinforcement T E 9362742009 9362742009 474 Turbo Fan Assy 9362803014 9362803014 476 2 Special Washer 9362756006 9362756006 477 Bellmouth B 9362774000 9362774000 479 Float Switch 9703285004 9...

Page 19: ...02 344 2 4 Way Valve 9353532008 354 Pressure Switch 9703667008 9704045003 381 4 Spacer 0600118075 0600118075 450 Discharge Pipe A 9370951028 527 Protection Net 9352163012 9352163012 575 Condensing Pipe C 9363460001 9363460001 620 Inlet Pipe Cond Assy 9353183002 9353183002 380 Locking Spacer 313209391403 313209391403 646 Compressor Cover B 9364089003 9364089003 678 Bracket Thermistor 313557406106 3...

Page 20: ...13714181904 313035356905 Large 313361275805 Small 313005446653 313005446759 9704339010 9363173000 1 each INDOOR UNIT ACCESSORIES Binder Coupler heat insulation Remote control unit cord clamp Special nut A large flange Special nut B small flange Remote control unit Template 9363265002 Blower cover insulation 9363168006 Hook wire STANDARD ACCESSORIES ...

Page 21: ...40100 301463040100 313035356905 313035356905 303020200114 303020200114 313005074759 313005074759 AOU42RC Power cap Auxiliary pipe assembly Edge cover Tapping screw Binder Putty Coupler heat insulation OUTDOOR UNIT ACCESSORIES Cap drain Pipe drain Flexible tube 313728031005 313013042915 313166024302 ...

Page 22: ...RICA INC 353 ROUTE 46W FAIRFIELD N J 07004 Parts Orders Parts maybe ordered from FUJITSU GENERAL AMERICA INC 353 RTE 46 W FAIRFIELD NJ 07004 PHONE 1 973 575 0380 Specify complete Parts No Model Descripation to ensure correct parts are supplied FAX 1 973 575 2194 ...