11. Safety devices
Type of
protection
Protection form
Model
AOYG07KMCC
AOYG09KMCC
Circuit protection
Current fuse (Main PCB)
250 V, 20 A
250 V, 5 A
Fan motor
protection
Thermal protection
Activate
100±15 °C
Fan motor stop
Reset
95±10 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Type of
protection
Protection form
Model
AOYG12KMCC
AOYG14KMCC
Circuit protection
Current fuse (Main PCB)
250 V, 20 A
250 V, 5 A
Fan motor
protection
Thermal protection
Activate
100±15 °C
Fan motor stop
Reset
95±10 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart