8-3. Current release control
The rotation number of compressor is controlled so that the outdoor unit input current does not ex-
ceeds current limit value set according to the outdoor temperature.
The rotation number of compressor returns according to the operation mode, when the current be-
comes lower than the release value.
¢
Model: AOUH18LPAS1
Operation mode
Outdoor temp. (Ta)
Trigger condition
Release condition
Cooling
122.0°F (50°C) ≤ Ta
7.0 A
6.5 A
114.8°F (46°C) ≤ Ta < 122.0°F (50°C)
7.0 A
6.5 A
104.0°F (40°C) ≤ Ta < 114.8°F (46°C)
9.0 A
8.5 A
53.6°F (12°C) ≤ Ta < 104.0°F (40°C)
9.0 A
8.5 A
35.6°F (2°C) ≤ Ta < 53.6°F (12°C)
9.0 A
8.5 A
Ta < 35.6°F (2°C)
9.0 A
8.5 A
Heating
62.6°F (17°C) ≤ Ta
7.0 A
6.5 A
53.6°F (12°C) ≤ Ta < 62.6°F (17°C)
9.0 A
8.5 A
41.0°F (5°C) ≤ Ta < 53.6°F (12°C)
11.0 A
10.5 A
Ta < 41.0°F (5°C)
11.0 A
10.5 A
¢
Model: AOUH24LPAS1
Operation mode
Outdoor temp. (Ta)
Trigger condition
Release condition
Cooling
122.0°F (50°C) ≤ Ta
7.0 A
6.5 A
114.8°F (46°C) ≤ Ta < 122.0°F (50°C)
7.0 A
6.5 A
104.0°F (40°C) ≤ Ta < 114.8°F (46°C)
9.5 A
9.0 A
53.6°F (12°C) ≤ Ta < 104.0°F (40°C)
13.5 A
13.0 A
35.6°F (2°C) ≤ Ta < 53.6°F (12°C)
13.5 A
13.0 A
Ta < 35.6°F (2°C)
13.5 A
13.0 A
Heating
62.6°F (17°C) ≤ Ta
7.0 A
6.5 A
53.6°F (12°C) ≤ Ta < 62.6°F (17°C)
9.0 A
8.5 A
41.0°F (5°C) ≤ Ta < 53.6°F (12°C)
13.0 A
12.5 A
Ta < 41.0°F (5°C)
13.0 A
12.5 A
8-4. Cooling pressure over-rise protection
When the outdoor unit heat exchanger temperature reaches trigger condition below, the compressor
is stopped and trouble display is performed.
Trigger condition
149.0°F (65°C)
8-5. Compressor temperature protection
When the compressor temperature sensor detects higher than the trigger condition below, the com-
pressor is stopped. When the compressor temperature sensor detects the release condition, the pro-
tection is released.
Trigger condition
226.4°F (108°C)
Release condition
176.0°F (80°C)
(3 minutes after compressor stop)
8-3. Current release control
- (04-30) -
8. Various protections
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for AOUH18LPAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 10 12 SR_CH01_AS051EF_02 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2021 07 04 SR_CH02_AS051EF_01 ...
Page 33: ...3 TROUBLESHOOTING 2021 08 04 SR_CH03_AS051EF_01 ...
Page 36: ......
Page 95: ...4 CONTROL AND FUNCTIONS 2021 08 04 SR_CH04_AS051EF_01 ...
Page 129: ...5 FILED WORKING 2021 08 04 SR_CH05_AS051EF_01 ...