2-3. Combination of external input and output
By combining the function setting of the indoor unit and rotary switch setting of the External input
and output PCB, you can select various combinations of functions.
Combination examples of external input and output are as follows:
Mode
Function
setting
Rotary
SW
External input
Indoor unit
External input and output PCB
CN46
1
CN313
2
CN314
0-1
60—00
1
Operation/Stop
(Function setting 46-00)
or
Forced stop
(Function setting 46-02)
Operation/Stop
Not available
Operation
Stop
0-2
60-00
2
Forced thermostat Off
Not available
1
60-01
3
Mechanical cooling
Off
2
60-02
4
Forced thermostat Off
3
60-03
5
Mechanical cooling
On
4
60-04
6
Mechanical cooling
On
5
60-05
7
Forced thermostat Off
6
60-06
8
Forced thermostat Off
7
60-07
9
Mechanical cooling
Off
8
60-08
A
Forced thermostat Off
9
60-09
B
Forced thermostat Off
10
60-10
C
Forced thermostat Off
11
60-11
D
Forced thermostat Off
12
60-12
D
Forced thermostat Off
NOTE:
Input of Operation/Stop depends on the setting of function setting 46.
00: Operation/Stop mode 1 (R.C. enabled)
01: (Setting prohibited)
02: Forced stop
03: Operation/Stop mode 2 (R.C. disabled)
2-3. Combination of external input and output
- (05-17) -
2. External input and output
FI
EL
D
W
O
R
K
IN
G
FI
EL
D
W
O
R
K
IN
G
Summary of Contents for AOUH18LMAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 11 01 SR_CH01_AS052EF_01 ...
Page 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 11 17 SR_CH02_AS052EF_04 ...
Page 39: ...3 TROUBLESHOOTING 2021 11 17 SR_CH03_AS052EF_01 ...
Page 42: ......
Page 135: ...4 CONTROL AND FUNCTIONS 2021 11 17 SR_CH04_AS052EF_01 ...
Page 138: ......
Page 173: ...5 FILED WORKING 2021 11 17 SR_CH05_AS052EF_01 ...