![Fujitsu AOTG30KMTA Design & Technical Manual Download Page 67](http://html.mh-extra.com/html/fujitsu/aotg30kmta/aotg30kmta_design-and-technical-manual_2344075067.webp)
- 63 -
O
U
T
D
OOR UNIT
AOTG30, 34KMT
A
10. Safety devices
Type of
protection
Protection form
Model
AOTG30KMTA
AOTG34KMTA
Circuit protection
Current fuse (Near the terminal)
250 V, 25 A
250 V, 25 A
Current fuse (Filter PCB)
250 V, 10 A
250 V, 10 A
Current fuse (Main PCB)
250 V, 3.15 A
250 V, 3.15 A
Fan motor
protection
Thermal protection
Activate
150±15 °C
Fan motor stop
—
Reset
120±15 °C
Fan motor restart
—
Thermistor protection
Activate
—
More than 80 °C
Fan motor speed down
Reset
—
80 °C or less
Fan motor speed recover
Compressor
protection
Terminal protection
program
(Compressor temp.)
Activate
120 °C
Compressor stop
Reset
80 °C
Compressor restart
Thermal protection
program
(Discharge temp.)
Activate
110°C
Compressor stop
Reset
After 7 minutes
Compressor restart
High pressure
protection
Pressure switch
Activate
4.2±0.1 MPa
Compressor stop
Reset
3.2±0.15 MPa
Compressor restart
Low pressure
protection
Pressure sensor
Activate
0.12 MPa
Compressor stop
Reset
0.15 MPa
Compressor restart
Summary of Contents for AOTG30KMTA
Page 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASTG30KMTA ASTG34KMTA ...
Page 15: ... 11 WALL MOUNTED ASTG30 34KMTA 5 Wiring diagram ...
Page 21: ... 17 WALL MOUNTED ASTG30 34KMTA 8 2 Sound level check point 0 8 m 1 m Microphone Microphone ...
Page 44: ... 40 WALL MOUNTED ASTG30 34KMTA ...
Page 45: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOTG30KMTA AOTG34KMTA ...
Page 56: ... 52 OUTDOOR UNIT AOTG30 34KMTA 3 Refrigerant circuit 3 1 Model AOTG30KMTA ...
Page 57: ... 53 OUTDOOR UNIT AOTG30 34KMTA 3 2 Model AOTG34KMTA ...
Page 58: ... 54 OUTDOOR UNIT AOTG30 34KMTA 4 Wiring diagrams 4 1 Model AOTG30KMTA ...
Page 59: ... 55 OUTDOOR UNIT AOTG30 34KMTA 4 2 Model AOTG34KMTA ...