7-13. Human sensor for energy saving
If no one enters the room for approximately 20 minutes, the set temperature is automatically con-
trolled. (→hen someone comes back into the room, the human sensor detect this, and automatically
revert to the original settings.)
Operation mode
Operation details
(If there is no one in the room for a while)
Cool/Dry
The setting temperature is increased by maximum 2°C.
(Maximum setting temperature: 30°C)
Heat
The setting temperature is decreased by maximum 4°C.
(Minimum setting temperature: 16°C)
Auto
Energy saving function is performed automatically for the selected mode
(cool/heat/dry).
• Application range:
Vertical angle 90
°
Side view
Horizontal angle 100
°
Top view
90
°
6 m
50
°
50
°
6 m
Energy saving function may not work when the room temperature is very different from the tem-
perature defined in the temperature setting, such as when immediately after starting the operation.
• Details about detection with the human sensor:
The human sensor detects whether there are people in the room by looking for movement by peo-
ple in the room.
7-14. Outdoor unit low noise operation
The outdoor unit low noise operation functions by OUTDOOR UNIT LO→ NOISE button on the re-
mote controller.
This operation stops the PFC control, and changes the current value.
Operation mode
Current
Trigger condition
Release condition
Cooling/Dry mode
1.9 A
1.4 A
Heating mode
7-13. Human sensor for energy saving
- (04-29) -
7. Various control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Summary of Contents for AOHG07KGCA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 3 11 SR_CH01_AS069EG_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 3 11 SR_CH02_AS069EG_01 ...
Page 33: ...3 TROUBLESHOOTING 2022 03 25 SR_CH03_AS069EG_01 ...
Page 36: ......
Page 89: ...4 CONTROL AND FUNCTIONS 2022 03 25 SR_CH04_AS069EG_01 ...
Page 91: ...8 6 High temperature and high pressure release control heating mode 04 32 CONTENTS continued ...
Page 92: ......
Page 125: ...5 FILED WORKING 2022 03 25 SR_CH05_AS069EG_01 ...