
- (01 - 22) -
F
L
O
O
R T
Y
P
E
A
G
G
0
9
-1
4
LV
C
B
F
L
O
O
R T
Y
P
E
A
G
G
0
9
-1
4
LV
C
B
EXTERNAL OUTPUT
11-2.
OPERATION STATUS OUTPUT
An air conditioner operation status signal can be output.
Circuit diagram example
z
Relay spec.:
Max.24V DC, 10mA to less
than 500mA.
Field supply
Ex.)Display
Indoor unit
control PC board
Connected unit
Ex.)Relay unit
1
2
Signal
Relay
power
supply
V
Connector
10m*
24V DC
* Make the distance from the PC board to the connected unit within 10m.
ON
OFF
Operation
Stop
Indoor unit
Output signal
Parts (Optional)
z
Parts name
Model name
External connect kit
UTY-XWZXZ5
Wire (External output) : UTY-XWZXZ5
Summary of Contents for AG G09LVCB series
Page 2: ...1 INDOOR UNIT FLOOR TYPE AG G09LVCB AG G12LVCB AG G14LVCB DTR_AG004E_03 2013 01 21 ...
Page 33: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LVCN AO G12LVCN AO G14LVCN DTR_AO094E_02 2013 01 21 ...
Page 40: ... 02 06 OUTDOOR UNIT AO G09 14LVCN OUTDOOR UNIT AO G09 14LVCN MODEL AO G14LVCN ...
Page 47: ... 02 13 OUTDOOR UNIT AO G09 14LVCN OUTDOOR UNIT AO G09 14LVCN SOUND LEVEL CHECK POINT 88888 ...