background image

En-7

 CAUTION

  Install the Front panel and Intake grille securely. If installation is imperfect, the Front 

panel or Intake grille may fall off and cause injury.

9.  

REMOTE CONTROLLER INSTALLATION

 CAUTION

• Check that the indoor unit correctly receives the signal from the remote controller, 

then install the remote controller holder.

• Select the remote controller holder selection site by paying careful attention to the 

following:
Avoid places in direct sunlight.
Select a place that will not be affected by the heat from a stove, etc.

9.1.  Remote controller holder installation

• Install the remote controller a maximum distance of 22 ft. (7 m) from the remote control 

receiver. However, when installing the remote controller, check that it operates correctly.

• Install the remote controller holder to a wall, pillar, etc. with the tapping screw.

Remote controller holder 

fi

 xing

Remote controller 
holder

(1) Set

(2) Push

Remote 

controller 

Tapping 

screw 

(small)

Remote controller mounting

10. OPTIONAL KIT INSTALLATION

 This air conditioner can be connected with the following optional kits.
 •  Wired remote controller
 •  Simple remote controller
 •  External connect kit

10.1. 

Before installing wired remote controller

•  When you use wired remote controller, some functions may not be used.

Please use the recommended optional remote controller.

 CAUTION

•  Before installing, be sure to disconnect all power supply.
•  Don’t touch the heat exchanger.
•  During installing or removing operation, be sure not to have wire caught by parts or 

draw it hard. Or it may result troubles to the air-conditioner.

•  Avoid place in direct sunlight.
•  Select place that will not be affected by the heat from a stove, etc
•  Before setting up the optional kit, please con

fi

 rm whether air-conditioner can receive 

the signal.

•  Do not connect the wired remote controller to the terminal for power supply.
•  When connecting the wired remote controller with the indoor unit, use the connecting 

cable (supplied with wired remote controller or simple remote controller).

•  Recommended cable length of wired remote controller is 32 ft. (10 m). Make sure to 

do insulate of connecting part when extended the cable.

10.2. 

Remote controller cable modi

fi

 cation

(1) Use a tool to cut off the terminal on the end of the remote controller cable, and then 

remove the insulation from the cut end of the cable.

(2) Connect the remote controller cable and connecting cable.

(supplied with wired remote controller)

Important:

 Be sure to insulate the connection between the wires.

Connecting cable

White

Red

White

Red

Black

Black

Insulated 
connection

Remote 
controller cable

Remote 
controller cable

13/16 in.  (20 mm)

Overlap the insulation

Vinyl tape

Wrap with cloth tape 

Cloth tape

Drain hose

Connection cable

Pipe

Drain hose

Check the following:

GOOD

Drain hose

Saddle

Lifted up

Wave

End in water

Drain hose

Connection pipe

Wall pipe

Connection cable

Left piping

For connection from the left rear

Pipe

Connection pipe 

(heat insulation)

Indoor unit pipe

(heat insulation)

PROHIBITED

Bind the pipes together 

so that there is no gap.

8.  FRONT PANEL REMOVAL AND INSTALLATION

8.1. Intake grille removal

(1)  Open the intake grille.
(2)  Pull down the knob.
(3)  Lift the intake grille upward, until the axle at the top of the intake grille is removed.

8.2. Intake grille installation

(1)  The 

fi

 xing axle of the intake grille is installed on the Panel.

(2)  Lay down the intake grille.

8.3. Front panel removal

(1)  Remove intake grille (Reference the intake grille removal.)
(2)  Remove 6 screws.
(3)   The thumb is hung on the lower part as shown in the 

fi

 gure, and it pulls to the front, 

pushing [

] mark , and bottom hooks (2 position) is removed from wall hook bracket.

(4)  The front panel is pulled to the front, raising the upper surface, and a front panel is 

removed.

8.4. Front panel installation

(1)  First, 

fi

 t the lower part of the front panel, and insert top and bottom hooks. (3 top 

sides)

(2)  Attach the 6 screws.
(3)  Attach the intake grille.

Top holes (two sides)

Top hole (center)

Top hook (center)

Front panel

Indoor unit

Top hooks

(2 sides)

Wall hook bracket

Front panel

Push

[

] mark

Screws (6 position)

Push

Front panel

Front panel

Bearing

Mounting shaft

Intake grille

Intake grille

Knob

9318739183_IM.indb   7

9318739183_IM.indb   7

11/19/2014   6:04:32 PM

11/19/2014   6:04:32 PM

Summary of Contents for 9318739183

Page 1: ... strong wood or metal frame to provide added support In a Room Properly insulate any tubing run inside a room to prevent sweating that can cause drip ping and water damage to walls and floors In an Area with High Winds Securely anchor the outdoor unit down with bolts and a metal frame Provide a suitable air baffle In a Snowy Area for Heat Pump type Systems Install the outdoor unit on a raised plat...

Page 2: ...gerant R410A have a different charging port thread diameter to pre vent erroneous charging with conventional refrigerant R22 and for safety Therefore check beforehand The charging port thread diameter for R410A is 1 2 20 UNF Be more careful that foreign matter oil water etc does not enter the piping than with refrigerant R22 models Also when storing the piping securely seal the opening by pinching...

Page 3: ...s or flammable dust or volatile inflammables such as paint thinner or gasoline If gas leaks and settles around the unit it can cause a fire Area where animals may urinate on the unit or ammonia may be generated Do not use the unit for special purposes such as storing food raising animals grow ing plants or preserving precision devices or art objects It can degrade the quality of the preserved or s...

Page 4: ...ping cut off the piping outlet cutting groove with a hacksaw CAUTION Insert the drain hose and drain cap into the drain port making sure that it comes in contact with the back of the drain port and then mount it If the drain hose is not connected properly leaking will occur Attach the Drain hose insulation to the drain hose Drain hose insulation Drain hose For left piping and left rear piping alig...

Page 5: ...ct with a flame CAUTION Connect the piping so that the control box cover can easily be removed for servic ing when necessary In order to prevent water from leaking into the control box make sure that the pip ing is well insulated When the flare nut is tightened properly by your hand hold the body side coupling with a wrench then tighten with a torque wrench See the table below for the flare nut ti...

Page 6: ... m M4 screw 11 to 16 1 2 to 1 8 CAUTION Attach the cable clamp firmly by holding the connection cable and make sure that the clamp is fixed securely Incomplete attachment of the cable clamp might cause a malfunction of the open panel Match the terminal block numbers and connection cable colors with those of the outdoor unit Erroneous wiring may cause burning of the electric parts Connect the conne...

Page 7: ...or simple remote controller Recommended cable length of wired remote controller is 32 ft 10 m Make sure to do insulate of connecting part when extended the cable 10 2 Remote controller cable modification 1 Use a tool to cut off the terminal on the end of the remote controller cable and then remove the insulation from the cut end of the cable 2 Connect the remote controller cable and connecting cab...

Page 8: ...onnecting cable to control board connector 1 Pass the cable from the hole in the back of indoor unit 2 Connect the cable to the control board connector 3 Hook the cable to the rib connect the cable rib CN6 CN16 CN14 PCB hole Option type Connector No Wired remote controller Simple remote controller CN6 External input CN14 External output CN16 4 Use cable clamper and screw to fasten the cable of wir...

Page 9: ...do not know the air conditioner custom code setting try each of the custom codes A B C D until you find the code which operates the air conditioner STEP 2 Selecting the Function Number and Setting Value 1 Press the SET TEMP buttons to select the function number Press the MODE button to switch between the left and right digits 2 Press the FAN button to proceed to setting the value Press the FAN but...

Page 10: ...nges When High insulation 01 is selected Overheating overcooling is prevented at the start up All room temp control settings Function 30 31 92 93 will reset to No correction 0 0 F 0 0 C Factory setting Function Number Setting Value Setting Description 95 00 Standard insulation 01 High insulation Room temperature control for indoor unit sensor Depending on the installed environment correction of th...

Page 11: ...ress the test run button with the tip of a ballpoint pen etc Transmitter section TEST RUN button To end test operation press the remote controller START STOP button When the air conditioner is running by pressing the TEST RUN button the OPERA TION Lamp and TIMER Lamp will simultaneously flash slowly Using the wired remote control Option For the operation method refer to the operating manual 1 Stop...

Page 12: ... temp sensor error 8 4 Current sensor error 8 6 Discharge pressure sensor error Suction pressure sensor error High pressure switch error 9 4 Trip detection 9 5 Compressor rotor position detection error 9 7 Outdoor unit fan motor error 9 9 4 way valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Di...

Reviews: