Problem Solutions and Tips
Fault Clearing
12.1.8 RAID Controller Indicates the Added Drive to be
Incorrect
This error message can have the following cause:
RAID controller not configured for the drive
Installation was occured with the system switched off.
Ê
Configure the RAID controller retroactively for the drive. You will find infor-
mation on this topic in the RAID controller documentation
or
Ê
Re-install the drive with the system switched ON.
If the drive is still found to be incorrect, it must be replaced (see
Swap for SCSI Hard Disk Drive” on page 48
).
12.1.9 Storage Subsystem cannot be Switched OFF by
the Server
A server connected to another SCSI module is still switched ON
I
As long as one of the servers is switched ON, the storage subsystem
remains switched ON via TERMPower.
The ON/OFF switch is in the “local on” position
Ê
Set the ON/OFF switch to the “remote on” position (see
).