U41169-J-Z156-4-74
89
Fault Clearing
Problem Solutions and Tips
12.1.4 Storage Subsystem Switches OFF
Temperature too high
The temperature sensors have measured an increased temperature and the
server has shut down the system.
Ê
Wait until the storage subsystem has cooled down.
12.1.5 System does not Start Up after New Drives have
been Installed
SCSI configuration incorrect (disk array controller)
Ê
Call up the configuration menu and check the drive settings (device config-
uration) and the additional settings (advanced configuration options).
12.1.6 Hard Disk Drive Operating Indication does not
Come ON
Ê
Check whether the hard disk drive has been correctly installed and locked
(see
section “Fitting/Removing Drive/Blank Insert” on page 44
Hard disk unit or SCSI backplane is defective
Ê
Replace the hard disk unit. If the operating indication is still OFF, the SCSI
backplane is defective. Contact the service organization.
12.1.7 Drives “dead” on System Start
Incorrect cabling
Ê
Ensure that the cabling and SCSI channel assignment correspond to the
original status.
Configuration of the disk array controller incorrect
Ê
Call up the RAID utility from the configuration disk or from the controller
BIOS of the RAID controller, and correct the settings for the drives.
You will find further notes in the disk array controller documentation.