C Remote Control Function
This server supports the Remote Control function.
When a personal computer (PC) is connected to the serial port of this server with an
RS-232C cross cable, the PC can be used to control the server power supply (turn
on/off and reset) remotely.
C.1
Preparation for Using Remote Control Function
To enable the remote control function, perform the following procedure.
• Configuring the BIOS
• Connecting the Server to a PC
• Configuring terminal software communication settings on the PC
■
Configuring the BIOS
To use the function of the server management port, perform the following setting using the BIOS Setup
Utility.
1
Turn on the server. Press the [F2] key during POST to start up the BIOS Setup
Utility.
2
Select the [Advanced] menu
→
the [Peripheral Configuration] submenu, and
set [Serial Multiplexer] to [iRMC].
3
From the [Exit] menu, select [Saving Changes & Exit] to exit the BIOS Setup
Utility.