![Fujitsu Siemens Computers PRIMERGY RX100 S4 User Manual Download Page 237](http://html.mh-extra.com/html/fujitsu-siemens-computers/primergy-rx100-s4/primergy-rx100-s4_user-manual_2344450237.webp)
237
PRIMERGY RX100 S4 User’s Guide
9
O
p
eration
a
nd
Mainten
ance
■
Message Recorded on System Event Log (SEL)
The following messages may be recorded when System Event Log (SEL) is displayed using ServerView
supplied with the server or Server Management Tools. It is not a problem for the server operation even if
the message is recorded.
■
Server Management Tools Error Messages
The following error messages may appear while executing Server Management Tools. Perform the
corresponding resolution listed in the table. If messages other than the following are displayed, contact
an office listed in the "Contact Information" of "Start Guide".
table: A Message on ServerView and Server Management Tools
Message displayed by
ServerView
Message displayed by Server
Management Tools
Explanations
Controller access degraded or
unavailable
ControllerAccessDegradedOrUnava
ilable-Asserted
This message shows that restart
process of Remote Management
Controller (iRMC) installed on the
server systemboard by default has
been executed. It is not a problem
for the continuous server operation.
table: List of Server Management Tools Error Messages
Message
Resolution
Write protect error writing drive A.
Abort, Retry, Fail?
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
Not ready writing drive A.
Abort, Retry, Fail?
The floppy disk is not inserted into the floppy disk drive.
Insert the proper floppy disk ("Server Management Tools"
disk), and then press the [R] key.
ERROR: Fail to create data file.
The following are possible causes. Check the floppy disk
status again.
• The floppy disk is not inserted into the floppy disk drive.
Insert the proper floppy disk, and then retry.
• The floppy disk is write-protected. Disable the write-
protect and retry.
• There is an error in the contents of the floppy disk. Create
the "Server Management Tools" disk again. If this
occurred while recovering BIOS information, configure
the information using the BIOS Setup Utility. Then store
the BIOS information.
ERROR: Fail to write 1st CMOS data into data
file. nn
ERROR: Fail to write 2nd CMOS data into data
file. nn
ERROR: Fail to write ESCD data into the data
file. nn
ERROR: Fail to write SEEPROM data into the
data file. nn
ERROR: Fail to open data file.
The file for recovering the BIOS information does not exist
on this floppy disk. Insert the floppy disk on which the BIOS
information was stored, and then retry.
ERROR: Fail to write 1st CMOS data into
system. nn
The following are possible causes. Check the floppy disk
status again.
• The floppy disk is not inserted into the floppy disk drive.
Insert the proper floppy disk, and then retry.
• A different model or an unsupported version of BIOS
information. Insert the proper floppy disk, and then retry.
• There is an error in the contents of the floppy disk. Create
the "Server Management Tools" disk again. If this
occurred while recovering BIOS information, configure
the information using the BIOS Setup Utility. Then store
the BIOS information.
ERROR: Fail to write 2nd CMOS data into
system file. nn
ERROR: Fail to write ESCD data into system file.
nn
ERROR: Fail to write SEEPROM data into
system. nn