9.2.2 Error Messages
This section explains the error messages for this server.
■
POST Error Messages
This section explains error messages of Power On Self Test: a device check performed during the server
startup (POST).
If an error occurs during POST, the following messages are displayed.
table: List of POST Error Messages
Message
Contents
Failure Fixed Disk
A IDE device error has occurred. Check the settings of "Parallel
ATA" in the [Main] menu on the BIOS Setup Utility. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
Stuck Key
A Keyboard error has occurred. Remove objects, if any, that are
pressing against any keys on the keyboard. Check to see
whether the keyboard is connected properly. If the message still
appears even after the server has been restarted, replace the
keyboard. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
Keyboard error
Keyboard controller error
A Keyboard controller error has occurred. Remove objects, if
any, that are pressing against any keys on the keyboard. Check
to see whether the keyboard is connected properly. If the
message still appears, replace the keyboard. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of "Start Guide".
System RAM Failed at offset: ********h
A memory error has occurred. Turn the server off and check that
the memory modules are installed properly. If the message
appears even after the server is turned on again, check the error
log and replace the memory modules (
Modules" (pg.181)). If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
Shadow Ram Failed at offset: ********h
Extended RAM Failed at address line: ****h
Memory type mixing detected.
The installing composition of the memory is wrong. Check if
the same type of memory modules are installed in slots in the
same bank. If the message still appears even after the proper
installation, replace the memory modules (
Memory Modules" (pg.181)). If the message still appears, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
Memory decreased in Size
A memory error has occurred. Accessible memory capacity has
become smaller than installed memory capacity due to a
memory module error. Check the error log and replace the
defective memory module (
"7.3 Installing Memory Modules"
(pg.181)). If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".