![Fujitsu Siemens Computers PRIMERGY RX100 S4 User Manual Download Page 183](http://html.mh-extra.com/html/fujitsu-siemens-computers/primergy-rx100-s4/primergy-rx100-s4_user-manual_2344450183.webp)
183
PRIMERGY RX100 S4 User’s Guide
Inst
a
llin
g I
n
te
rn
al O
p
tions
7
7.3.3 How to Install/Remove Memory Modules
1
Turn off the server and remove the top cover.
"7.2 Removing and Attaching the Top Cover" (pg.178)
2
Touch a metal part of the server to discharge static electricity.
3
Install or remove memory modules.
• Installing
Insert a memory module properly into the memory slot. The levers close.
If the levers are not closed completely, push them with your fingers.
• Removing
Open the levers on both ends.
4
Check that the memory module is inserted all the way.
5
Attach the top cover.
"7.2 Removing and Attaching the Top Cover" (pg.178)
• Make sure not to open the clips outward too quickly because the memory
module may pop up, which could cause damage.
• An improperly engaged memory module could cause a fire. Do not insert the
memory module on the wrong side.
Lever
Align notch