Page 2: ...IOS Update zu unseren Mainboards finden Sie im Internet http www fujitsu siemens com mainboards Are there any technical problems or other questions you need clarified Please contact your sales partner your sales outlet You will find further information in the manuals Safety and Ergonomics The latest information and updates e g BIOS update on our mainboards can be found on the Internet under http w...

Page 3: ......

Page 4: ... impreso sobre papel reciclado Questo manuale è stato stampato su carta da riciclaggio Denna handbok är tryckt på recyclingpapper Dit handboek werd op recycling papier gedrukt Herausgegeben von Published by Fujitsu Siemens Computers GmbH Bestell Nr Order No A26361 D1501 Z120 1 7419 Printed in the Federal Republic of Germany AG 0203 02 03 A26361 D1501 Z120 1 7419 ...

Page 5: ...Mainboard D1501 Technisches Handbuch Technical Manual Deutsch English Ausgabe Februar 2003 February 2003 edition ...

Page 6: ... technische Änderungen vorbehalten Dieses Handbuch wurde erstellt von cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Intel Pentium and Celeron are registered trademarks of Intel Corporation USA Microsoft MS MS DOS and Windows are registered trademarks of Microsoft Corporation PS 2 and OS 2 Warp are registered trademarks of International Business Machines Inc All other trademar...

Page 7: ...ts and connectors 6 Temperature System monitoring 7 IDE connector 8 LAN connector 8 PCI bus interrupts 9 SCSI HostRAID configuration programme 9 SCSI Disk Utilities 16 Jumper settings 17 Clear CMOS RAM JP 14 17 Boot Block JP 15 17 BMC Power On Control JP 16 17 Add on modules 18 Installing the processor with heat sink and fan 19 Upgrading main memory 21 Replacing lithium battery 22 Glossary 23 ...

Page 8: ......

Page 9: ...ies you make via the keyboard Text in italics indicates commands or menu items Quotation marks indicate names of chapters or terms Important notes With the mainboard installed you must open the system to access the mainboard How to dismantle and reassemble the system is described in the operating manual accompanying the system Connecting cables for peripherals must be adequately shielded to avoid ...

Page 10: ...the mains outlet so that system and mainboard are totally disconnected from the mains voltage Be careful with the locking mechanisms catches centring pins etc when you replace the mainboard or components on it for example memory modules or processors Never use sharp objects screwdrivers for leverage Boards with electrostatic sensitive devices ESD are identifiable by the label shown When you handle...

Page 11: ...a 320 capable Host RAID implemented with SCSI Controller The RAID levels 0 1 and 10 are supported Video Controller ATI Rage XL with 8 Mbyte SDRAM Gigabit LAN controller Intel 82540EM 10 100 1000 MBit s IDE hard disk controller connected to PCI bus for up to two IDE hard disks mode capable supports PIO modes 3 and 4 Floppy disk drive controller possible formats 720 Kbyte 1 44 Mbyte Flash BIOS syste...

Page 12: ...ar with integrated battery backup 1 internal USB port 1 external parallel port ECP and EPP compatible two external serial ports COM1 and COM2 two external USB ports USB Universal Serial Bus 1 LAN connector RJ45 1 VGA port two external PS 2 ports for keyboard and mouse ...

Page 13: ...Serial interface 1 COM1 6 Parallel port 7 Serial interface 2 COM2 8 LAN connector 9 USB ports A and B 10 VGA port Baseboard management controller format 60 x 50 mm Interrupt Controller Chipset Winbond W83910F and W24100S EEPROM 2 Mbyte Winbond W39F010P 80 pin connector quartz frequency 40 000 MHz and 32 768 KHz Installing on the mainboard 2 screws M2x5 mm ...

Page 14: ...IMM 4 19 20 1 SMBTerm 2 USB ports 3 Power supply monitoring 4 Power supply ATX 5 Floppy Disk Drive 6 IDE drives 1 and 2 primary 7 IDE drives 3 and 4 secondary 8 IPMB 9 SMB 1 10 JP16 11 Cover monitoring 12 JP15 13 SCSI connection 14 Connector for front panel 15 VCC_RSB Remote Service Board 16 Buzzer 17 System fan 18 Power supply 12 V for processor 19 Processor fan 20 JP14 ...

Page 15: ...he fan monitoring function Blocked fans are operated with 12 V pulse voltage An attempt is made to restart a blocked system fan with a cyclical voltage pulse If the system fan is removed with the device switched off this results in an error message when the device is switched on again This is indicated optically by the flashing of the system error LED on the control panel In addition an entry is g...

Page 16: ...nector Ê The system is equipped with two independent ATA 100 interfaces The Chip disk is always to be connected on the Primary IDE connector The CD ROM DVD CD RW drive is to be connected on the Secondary IDE connector LAN connector This mainboard has an Intel gigabit LAN controller This LAN controller supports the transfer rates of 10 Mbit s 100 Mbit s and 1 Gbit s The LAN controller is equipped w...

Page 17: ...e listing the SCSI devices connected is displayed i If an SCSI BIOS error message appears or problems arise with SCSI devices please read the documentation of your SCSI device If you are unable to trace or rectify the error please contact your dealer or our customer service centre Working with the keyboard Use the following keys when running the programme ËÊ to select an entry Ú to accept a select...

Page 18: ...mpted to store them Ê To quit the Configuration programme press the ESC key until a corresponding message is displayed Select Yes to quit Ê Activating and Configurating Host RAID To configurate HostRAID select the menu entry Configure View HostRAID Settings If this entry is not displayed you have to activate HostRAID with the entry Enable HostRAID Support Now the exsisting SCSI hard disks and alra...

Page 19: ... Sync Transfer Rate MB Sec 320 Packetized Yes QAS Yes Initiate wide negotiation Yes Enabled Enable disconnection Yes Enabled Send Start Unit Command Yes BIOS Multiple LUN Support No Include in BIOS Scan Yes Advanced Configuration Press Enter Reset SCSI Bus at IC Initialization Enabled Display Ctrl A Message During BIOS Initialization Enabled Extended Int 13 Translation for DOS Drives 1Gbyte Enable...

Page 20: ...f the SCSI controller must be enabled The default setting is Enabled The terminating resistor of the SCSI controller is enabled With F6 you can reset to the default setting Additional Options Master SCSI Controller These settings display from which of the available SCSI controller the BIOS is loaded As long as the onboard SCSI controller AIC 7901 is activated only this one is the master controller...

Page 21: ...e SCSI controller attempts 16 bit data transfer Wide negotiation instead of 8 bit data transfer As a result two byte are transferred simultaneously via the SCSI bus instead of one byte Enable disconnection The default setting is Yes enabled This permits SCSI devices to enable the SCSI bus during command execution A typical example of this is a tape device that has no need to access the SCSI bus du...

Page 22: ... still invoke the SCSI configuration programme by pressing CTRL and A at system bootup Extended Int 13 Translation for DOS Drives 1Gbyte The default setting is Enabled Normally only drives with a capacity of up to 1 Gbyte can be accessed Enabling this option allows drives of up to 8 Gbyte capacity 2 Gbyte partition to be supported under MS DOS 5 0 or higher The SCSI controller BIOS must be enabled...

Page 23: ...l drivers to access drives if the Int 13 support of the U320 SCSI controller is disabled Domain Validation The default setting is Enabled The SCSI controller checks with a short test whether the transmission rate set under Sync Transfer Rate is possible If errors occur the transmission rate is reduced as far as no more errors occur Support Removable Disks under Int 13 as Fixed Disks This option al...

Page 24: ...erify and Format Disk Verify With Verify you can have a selected hard disk drive checked All defects that are detected will be entered in the existing error list for the hard disk Format Disk With Format Disk a selected hard disk is formatted in low level format Normally hard disks are already formatted in low level format You should use this menu item only if you want to erase the hard disk compl...

Page 25: ...the old system BIOS after an attempt to update has failed To restore the old system BIOS you need a Flash BIOS Diskette please call our customer service centre 1 2 The System is started with the system BIOS from the mainboard default setting 2 3 The system boots from the Flash BIOS floppy disk from Drive A and reprograms the system BIOS on the board BMC Power On Control JP 16 The jumper JP16 allow...

Page 26: ...MM 1 DIMM 2 DIMM 3 DIMM 4 1 4 5 6 3 8 7 2 1 Socket for processor with heat sink 2 Location bank 1 for main memory 3 Location bank 2 for main memory 4 Location bank 3 for main memory 5 Location bank 4 for main memory 6 Baseboard management controller BMC 7 Lithium battery 8 PCI slots 1 2 3 4 5 The PCI slots 2 5 are supplied with 5 V main voltage the PCI slot 1 with 3 3 V PCI slot 1 supports a Zero ...

Page 27: ...nting heat sink If you are installing the heat sink you must ensure a good heat contact between heat sink and the processor s surface It is essential to use heat conducting material between the processor and the heat sink If you remove the heat sink you must clean it e g with benzine and apply new heat conducting paste before you remount it Please note that depending on the heat sink used differen...

Page 28: ...sink Ê Remove the protection cover from the underside of the heat sink When using the previous heat sink Ê Apply an even coat of heat conducting paste to the entire surface of the processor and mount the heat sink on it Ê Fix the heat sink with the supplied retaining springs ...

Page 29: ...d memory modules are not allowed and lead to a device failure DIMM memory modules must meet the PC2100 specification Installing a memory module 2 2 Ê Push the holders on each side of the memory slot outwards Ê Push the memory module into the location 1 Ê At the same time flip the both lateral holders upwards until the memory module snaps in place 2 Removing a memory module 1 1 Ê Push the clips on ...

Page 30: ...hium battery may be replaced only with an identical battery or with a type recommended by the manufacturer Do not throw lithium batteries into the household waste They must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top The lithium battery holder exists in different designs that...

Page 31: ...U Central Processing Unit RAMDAC Random Access Memory Digital Analogue Converter CNR Communication Network Riser RDRAM Rambus Dynamic Random Access Memory C RIMM Continuity Rambus Inline Memory Module RIMM Rambus Inline Memory Module DIMM Dual Inline Memory Module RTC Real Time Clock ECC Error Correcting Code SB Soundblaster EEPROM Electrical Erasable Programmable Read Only Memory SDRAM Synchronou...

Page 32: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...