background image

1U030981

READ AND SAVE THESE INSTRUCTIONS.

Keep this manual in a convenient place for future reference.

FUJI INDUSTRIAL CO., LTD.

TABLE OF CONTENTS

Safety Instructions .................................................................................................. 2
Name of Parts ......................................................................................................... 4
Size & Dimensions .................................................................................................. 4
Range Hood Location ............................................................................................. 5
Installation ............................................................................................................... 6

1. Preparation ..................................................................................................... 6
2. Range Hood Mounting .................................................................................... 9
3. Connecting Power Supply Wires ................................................................... 11
4. Final Assembly and Check ............................................................................ 13
5. Explanation to the End User ......................................................................... 14

Circuit Diagram ..................................................................................................... 14

Installation Manual
RANGE HOOD

MODEL: BUF-03R

Summary of Contents for BUF-03R

Page 1: ...CO LTD TABLE OF CONTENTS Safety Instructions 2 Name of Parts 4 Size Dimensions 4 Range Hood Location 5 Installation 6 1 Preparation 6 2 Range Hood Mounting 9 3 Connecting Power Supply Wires 11 4 Final Assembly and Check 13 5 Explanation to the End User 14 Circuit Diagram 14 Installation Manual RANGE HOOD MODEL BUF 03R ...

Page 2: ...y When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 2 To reduce the risk of fire or electric shock do not use this product with any solid state speed control device 3 TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by a qualif...

Page 3: ... Do not vent exhaust air into spaces within walls ceilings or into attics crawl spaces or garages 6 Fasten the filter and other parts securely Incorrect attachment may result in personal injury or property damage 4 Use only for the purpose of kitchen ventilation 1 For general ventilating use only Do not use to exhaust hazardous or explosive material and vapors 7 Keep your hands and other objects a...

Page 4: ...4 NAME OF PARTS SIZE DIMENSIONS Accessories Accessories Accessories Accessories Accessories Unit inch Screw M5 30 Four 4 pieces Nut with plate Four 4 pieces ...

Page 5: ...weight of the BUF 03R range hood unit is BUF 03R 18 lbs 8 kg 4 Power requirements are AC120 V 60 Hz 1 8 Amp RANGE HOOD LOCATION CAUTION Check that the hood is correctly installed since incorrect installation could result in the detachment of the range hood and the unit could fall off To protect hands from injury wear working gloves when installing the range hood ...

Page 6: ... vertical or horizontal discharge run duct work between the hood location and a roof cap or wall cap For the best results in either directions use a minimum number of transitions and elbows Be sure to attach a roof cap or wall cap to avoid leaking rain in the end 2 The range hood unit must be mounted to a liner which has the following dimensions Install the liner securely after checking that the o...

Page 7: ...ith the exhaust pipe fixed on its top plate 2 Provide a transition duct not supplied to connect the exhaust pipe and external duct For the size of transition duct refer to Fig at right 3 Be sure to keep 1 3 16 overlapping length of the exhaust pipe and transition duct when installing 4 Skip to page 9 for mounting the range hood INSTALLATION continued ...

Page 8: ... and attach it as shown in Fig 4 Attach the range hood to the liner Refer to page 9 for details 5 Connect the exhaust pipe with the duct then make the duct joint secure and air tight using non flammable tape such as duct tape etc not supplied 6 Attach the exhaust pipe to the range hood with 4 screws M4 8 from out side of the wall 7 Connect the duct to out side wall cap not supplied CAUTION To prev...

Page 9: ...h sides have passed through the top of the liner turn them outward to secure the range hood on the liner temporarily Make sure that the top of the exhaust pipe is inserted into the bottom of the transition duct INSTALLATION continued 2 Remove 4 screws which are fixed to the front cover The front cover swings open 90 as shown in Fig ...

Page 10: ...careful not to damage the hinge part 4 Align 4 screw holes of the liner and range hood unit then fix securely using the supplied screws M5 30 and nuts NOTE Fasten all screws and nuts evenly 5 Make the duct joint secure and air tight using non flammable tape such as duct tape etc not supplied NOTE Make sure that the shutter installed in the exhaust pipe moves freely 1 2 ...

Page 11: ... electric shock or injury This range hood uses 120V AC Do not connect to other voltage since fire electric shock or damage could result 1 Remove the nut from the conduit connector at the end of power wiring WARNING Be sure to switch power OFF at service panel before wiring 2 Remove one screw fixing the wire cover and detach it 3 Connect the conduit through the connecting hole of the body using the...

Page 12: ... Connect wires tightly and securely using wire connectors not supplied Black to Black White to White Green to Green 5 Replace the wire cover with the screw removed previously Make sure that all wires are connected properly and enclosed inside of the wiring compartment ...

Page 13: ... the screws with the torque of 13 inch lbs 1 5 N m or less Be sure to connect the wire connector rightly Otherwise the range hood won t work properly 2 Check 1 Turn on the electrical circuit to the range hood 2 Make sure that the switch and light operate correctly Refer to page 4 of the Operation Manual 3 Check the ventilating functions at Hi Me and Lo positions 4 Make sure that the range hood has...

Page 14: ...The Installation Manual and Operation Manual should be given to the end user INSTALLATION continued CIRCUIT DIAGRAM Motor Connector Connector Terminal Capacitor Red Red Red White White Orange Brown Blue White Orange Brown Blue Green Green Black Black White Orange Brown Blue Green Black 120V 60Hz Bulb Max40W Control Switch ...

Page 15: ...Fuji Industrial USA Inc 16300 Christensen Rd Ste 212 Seattle WA 98188 3403 Telephone 1 888 547 9880 ...

Reviews: