54
Function Introduction
3.
IPA Data (FSM-100P/100P+ Only)
3-1.
IPA Data
The splicer aligns theta by using the memorized IPA data of each fiber.
PAS is recommended for the PANDA fiber alignment. The alignment of high speed
and accuracy is enabled.
Please use the IPA mode when PANDA alignment is impossible.
Method of acquiring Fiber Profiling Data
The fiber to memorize the profile data is set on the left side with glass clamping.
On the right side, the PM fiber that profiled data is already memorized in the
splicer with glass clamping. More accurate align can be done by connecting
with the light source and the power meter and executing this IPA data. To
acquire more accurate IPA data, use the light source and PER meter for precise
alignment.
(1)
Select the IPA Data in the Fiber Data Learning menu.
Select the saving area for the IPA data and input the data name.
Execute the acquiring of IPA data according to the guidance.
The fiber is rotated.
And, fiber information is
memorized.