13
Description of Products
2.
Optional Components
Fiber Holder
Name
Model
Note
Fiber Holder
FH-100-060
60μm
Applicable Diameter: 55~71μm
FH-100-100
100μm
Applicable Diameter: 94~117μm
FH-100-125
125μm
Applicable Diameter: 118~39μm
FH-100-150
150μm
Applicable Diameter: 140~169μm
FH-100-180
180μm
Applicable Diameter: 170~199μm
FH-100-210
210μm
Applicable Diameter: 200~239μm
FH-100-250
250μm
Applicable Diameter: 240~289μm
FH-100-300
300μm
Applicable Diameter: 290~339μm
FH-100-350
350μm
Applicable Diameter
:
340~389μm
FH-100-400
400μm
Applicable Diameter: 390~489μm
FH-100-500
500μm
Applicable Diameter: 490~589μm
FH-100-600
600μm
Applicable Diameter: 590~689μm
FH-100-700
700μm
Applicable Diameter: 690~789μm
FH-100-800
800μm
Applicable Diameter: 790~889μm
FH-100-900
900μm
Applicable Diameter: 890~1000μm
FH-100-****
****um
Applicable Diameter: 1000~2000μm
FH-40-LT900
900μm
Loose Tube
Fiber holder placement for fibers with cladding larger than 250µm
• Please change the direction of the fiber holder as shown below when the size of
the fiber cladding is larger than 250µm. Better alignment and splicing
performance will be achieved for such large diameter fibers (LDF) when there is a
longer distance between the fiber holder clamps and the splicer’s alignment
V-grooves.
•Fiber holder position can be reversed on FSM-100M/P. Use this function to allow
fiber holder to be placed as far as possible from v-groove so that the fiber ends are
aligned accurately.
Set the fiber holder in reverse direction