KSP75-FP-011135
(
1
)
6. Lift the Lever(1) until it stops and remove the fiber from the cleaver. Be careful
not to touch the fiber to anything, as this can contaminate the end-face of the fiber.
7. The fiber scrap is put into the Fiber Scrap Box after cleaving. Properly dispose it.
6. Maintenance
Properly clean the cleaver to ensure consistent cleaving quality. If the cleaver does
not cleave properly after cleaning, rotate the blade or change the blade height. Refer
to 6-3.
NOTE:
Use the 1.5mm hex wrench, “HEX-01”, when changing the Blade
Position and Height. This is included with your cleaver.
6-1. Cleaning
Clean all parts that the optical fiber touches with an alcohol moistened gauze or a
cotton swab.
If the cleaver is exposed to water, dry it with a dry gauze to prevent any rust.
NOTE:
Do not to touch the blade during cleaning.
6-2. Change Blade Position
Check the bottom of the CT08. There is a Blade Rotating Dial(8) that changes the
blade position. The CT08 uses a circular blade that has 16 positions. Each position
can cleave 1,000 fibers. Rotate to the next number for a new blade position.
Procedure:
1. Check the Blade Positon Number(7) printed to the side of the blade.
2. Close the Lever(1) and then rotate the Blade Rotating Dial(8) in the direction of
the arrow until it clicks.
3. Check that the Blade Position(7) has advanced to next number.
6-3. Change Blade Height
The Blade height can be changed by rotating the Adjuster(10) located on the top of
the cleaver. It can be raised a total of 2 times.
Procedure:
1. Verify the position of the Blade Height Adjuster(10).
2. It is locked by the Adjuster Set Screw(11) to prevent turning. Fig.6-2.
3. Loosen the set screw with the HEX-01 and then rotate the Adjuster(10) one
mark. Do not rotate more than one mark at one time.
4. Tighten the Adjuster Set Screw(11). Overtightening may cause breakage.
NOTE:
Replace the blade after raising it 2 times, and after all 16 positions
have been used.
The Cleave Blade and Arm set for CT08 is user serviceable. Contact
your Fujikura distributor for details.
7. Cleaver Disposal
The CT08 contains no toxic substances and no recyclable material. If the CT08
needs to be disposed, it should be discarded as noncombustible material.
8. Contact Address
Inquiries concerning products should be made to the
nearest sales agency or one of the following:
Fujikura Europe Ltd.
C51 Barwell Business Park Leatherhead Road,
Chessington, Surrey KT9 2NY,UK
Tel. +44-20-8240-2000 (Service: +44-20-8240-2020)
Fax. +44-20-8240-2010 (Service: +44-20-8240-2029)
URL http://www.fujikura.co.uk
AFL
260 Parkway East Duncan, SC 29334, U.S.A.
Tel. +1-800-235-3423 (Service: +1-800-866-3602)
Fax. +1-800-926-0007 (Service: +1-800-433-5452)
P.O.Box 3127 Spartanburg, SC 29304-3127
URL http://www.AFLtele.com
Fujikura Asia Ltd.
438A Alexandra Road, Block Alexandra Techno Park
#08-03, Singapore 119967
Tel. +65-6278-8955 Fax. +65-6273-7705
URL http://www.fujikura.com.sg
Fujikura Ltd.
1-5-1 Kiba, Koto-ku, Tokyo, 135-8512, Japan
Tel. +81-3-5606-1164 Fax. +81-3-5606-1534
URL: https://www.fusionsplicer.fujikura.com
Fig.6-1 Changing the Blade Position
(7) Blade Position Number
(8)Blade Rotating Dial
(9)Arrow
Adjuster initial position
Rotate clockwise
to raise blade
height
(10)Adjuster
(10)Adjuster
(11)Adjuster Set Screw
Fig6-2. Blade Height changing
(5)Fiber Plate
[AD-50]
(6)Fiber Holder
(1)Lever
Fig.5-2 Cleaving