FUSION SPLICER 90S Rev5
73
Deleting Heater Mode
Heater mode can be erased. Follow the below steps to erase heater mode.
1.
Select the icon in the [Heater Mode] menu, to show the heater
mode details.
2.
Select [Sleeve Type] and change to [BLANK]
Detail of the parameter in Heater Mode Menu
The parameters in the Heater Mode Menu are listed below:
Parameter
Description
Sleeve type
Sets sleeve type. List of all heating modes are
displayed. Select a mode in the list and this is copied
to a user-programmable mode.
Mode Title1
Title of a heater mode that is displayed in the lower
right part of the monitor during the splicing/heating
process. Max number of characters used is 7.
Mode Title2
Description of a heater mode in the [Sleeve Type]
screen. Max number of characters used is 15.
Heat Time
Sets heating time from the beginning to the end (cool-
down completion). Heating time is automatically
adjusted with atmospheric conditions, such as
ambient temperature. Heating time may be longer or
shorter than [Heat time] set.
Heat Temperature
Sets heating temperature.
Finish Temperature
Sets the finish temperature. The buzzer beeps after
completion of the heating.
Caution
Do not touch the shrunken sleeve after removing the
fiber from the tube heater. It may be hot. Hot sleeves
easily deform and can cause some residual stress at
the splice point. Use J-plate to cool down the sleeve.