62S_Rev3
50
Splice Menu
Composition of Splice Menu
Common parameters for the modes for splicing and machine setting can be set.
1.
Press MENU key at [READY], [PAUSE] or [FINISH] state to open [Splice Menu].
2.
Move cursor by pressing Up/Down Arrow key to a parameter to be selected.
3.
Press ENT key to change values and settings.
Setting parameters
Parameter
Description
Select Splice
Mode
Mode according to the fiber to splice can be chosen.
Pause1
f "Pause1” is set to “ON”, the splicing operation pauses when fibers are
forwarded to gap-set position. Cleave angles are displayed during the pause.
Pause2
If “Pause 2” is set to "ON", the splicing operation pauses after fiber alignment
is completed. With ECF “ON”, core-to-core alignment is made after this
pause.
Auto Start
Trigger
Select of "On", and "OFF" can be performed.
Memory
A situation can be checked after splicing with this machine.
Splice Memory
Comment
A comment can be added to the memory saved at the time of the end
of connection.