25
4. SETUP AND MAINTENANCE
4
<Channel Registration>
NOTE: Before channel registration, register the DX code and film
name.
1. Enter channel number to be registered in the “CH No.” box.
There are 128 film channels.
2. Enter film name in the box next to the “CH No.” box.
3. Select “Register”.
• The registered channel is added to the “Special Film CH
Selection” dialog box accessed from the “Process 1”
screen and used when the DX code cannot be read.
(See the “Operating Instructions” manual.)
4. Select the tone in the “Tone” box.
Tone: Color
Sepia 1
Sepia 2
B/W
5. Set up the “Balance/Slope” for Color and the “Balance” for
Sepia 1, 2 and B/W.
6. Enter the DX code registered in the “DX Code” box.
7. Click the [Register] button.
• The DX code is listed in the “Registered DX Code” box.
8. Click the [OK] button.
• Operation returns to the menu screen.
<Deleting>
1. Select the channel number to be deleted in the “CH No.” box.
• The DX code and name are displayed in the “Registered
DX Code” box.
2. Click the [Delete] button.
• The DX code is deleted.
3. Click the [OK] button.
• Operation returns to the menu screen.
4.3.5 Monotone Correction Setting (0224)
Monotone correction setup in this menu can be accessed from
the “Process 1” screen regardless of the film types (see the
“Operating Instructions” manual).
[Selection]
[Setup and Maintenance]
→
[02 Print Condition Setup and
Check]
→
[0224 Monotone Correction Setting]
[Procedure]
Fine-adjust the balance values for the correction type in the
“Monotone Correction” dialog box in the “Process 1” panel in this
mode.
1. Select the correction type to be adjusted in the “Input Type”
box.
Input Type: Negative
Reversal
2. Select the correction type to be adjusted in the “Correction”
box.
Correction: B/W
Sepia 1
Sepia 2
User B/W
User Sepia 1
3. Change the color balance values.
4. Click the [OK] button.
• Operation returns to the menu screen.
4.3.5