5.2.2 Heat Force Parameter Counter Reset
When driving the capping unit motor for a long time (for Initial Charge & cleaning or
continuous cleaning, etc.), a cool down period (a stand-by state) may be automatically taken
as the “heat generation control sequence”. This sequence prevents the motor from being
overheated and damaged due to long time operation. If the printer is turned off when this
sequence is on, the printer will be still in this sequence the next time the printer is turned on
and will enter a stand-by state. To prevent this from happening, reset the heat generation
control sequence counter after operating the capping unit motor for a long time.
a
1.
Select
1. Adjustment / Maintenance
Maintenance
Heat Force Parameter
Counter Reset
.
2.
Click
[Reset]
.
Figure 5-5. Heat Force Parameter Counter Reset Screen
C A U T I O N
Do not reset the heat generation control sequence counter to execute
continuous cleaning forcibly.
Summary of Contents for Frontier-S DX100
Page 13: ...13 DX100 Service Manual 7 3 Board Layout Diagram 299 7 4 Board Voltage List 303...
Page 14: ...C H A P T E R 1 PRODUCTDESCRIPTION...
Page 29: ...C H A P T E R 2 OPERATINGPRINCIPLES...
Page 46: ...C H A P T E R 3 TROUBLESHOOTING...
Page 76: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY...
Page 208: ...C H A P T E R 5 ADJUSTMENT...
Page 279: ...C H A P T E R 6 MAINTENANCE...
Page 296: ...C H A P T E R 7 APPENDIX...
Page 298: ...298 7 2Connector Summary DX100 Service Manual 7 2 Connector Summary PW sensor...
Page 302: ...302 7 3Board Layout Diagram DX100 Service Manual Power Supply Board...