182
4.5Disassembly and Assembly Procedure
DX100 Service Manual
4.5.7.5 Capping Unit
1.
Remove the Right IC Holder Cover Open Sensor.
2.
Remove the Top Cover.
3.
Remove the Upper Cover.
4.
5.
Remove the Right Frame.
6.
Remove the Maintenance Cartridge Cover.
7.
Remove the Trimmed Waste Paper Box.
8.
Remove the Front Cover.
9.
Disconnect the cable of the Capping Unit from the connector (CN203) of the Main
Board.
10. Release the cable of the Capping Unit from the four clamps and two wire saddles.
11. Remove the omega clamp, and release the cables.
Figure 4-146. Releasing the cable
Main Board
CN203
Clamp
Clamp
Clamp
Clamp
Wire saddles
Capping Unit
Omega clamp
Summary of Contents for Frontier-S DX100
Page 13: ...13 DX100 Service Manual 7 3 Board Layout Diagram 299 7 4 Board Voltage List 303...
Page 14: ...C H A P T E R 1 PRODUCTDESCRIPTION...
Page 29: ...C H A P T E R 2 OPERATINGPRINCIPLES...
Page 46: ...C H A P T E R 3 TROUBLESHOOTING...
Page 76: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY...
Page 208: ...C H A P T E R 5 ADJUSTMENT...
Page 279: ...C H A P T E R 6 MAINTENANCE...
Page 296: ...C H A P T E R 7 APPENDIX...
Page 298: ...298 7 2Connector Summary DX100 Service Manual 7 2 Connector Summary PW sensor...
Page 302: ...302 7 3Board Layout Diagram DX100 Service Manual Power Supply Board...