12-19
12.3 Sub-scanning Unit
12
Removal
NOTE: Wear clean gloves when handling the steel belt and
pulley. Fingerprints on the belt and pulley may cause
slippage or corrosion of the belt.
1. Remove the frame
2. Loosen the three screws securing the motor bracket.
3. Move the motor bracket to loosen the belt tension
and tighten the one screw lightly.
4. Wear clean gloves and remove the belt.
5. Wipe the pulley surface clean with a cloth
moistened with alcohol solution (mixture of an
equal amount of alcohol and water).
12.3.3
Sub-scanning Steel Belt Replacement
LII429
Screws (3)
LII430
Bracket
Screw
LII431
Belt