93
FMPC
8.2.4
Timer Setup (414)
[Selection]
“4 Setup and Maintenance” - “1 System Operation
Setup and Check” - “4 Timer Setup”
[Procedure]
The present date/time, timer ON date/time and
preheat setup times are setup.
1
To update “Present Date/Time”, change the date
and time, and click [OK].
NOTE:
To cancel the update, press the [Cancel] button.
2
To change the timer date and time, check the
day of the week and enter the time in the “Timer
ON Date/Time Setting” box.
3
Setup the preheat timer by following the steps on
the next page, if necessary.
IMPORTANT
The ON time for a night-time preheating
operation must not overlap with the ON time of
the weekly timer since night-time preheating
takes priority and shuts down all power when it is
set OFF.
If, for instance, the calendar timer is set to 5:00
AM and night-time preheating is turned ON at
3:30 AM, all the power will be shut down two
hours later at 5:30 AM.
NOTE:
Night-time preheating is usually conducted when
the room temperature drops below 10 °C (50 °F) at
night and the temperature is not controlled for 8 or
more hours.
(1) Select “YES” for “Preheat Setting”.
• The 1st and 2nd preheat setting boxes appear.
(2) Move the cursor to “1st Preheat” and enter the
time.
(3) Move the cursor to “2nd Preheat” and enter the
time.
NOTE:
• For preheating only once, set the same time for
both the first and second times.
• Select “NO” when no preheat timer is used.
• The second preheating timer is ignored if the
first and second times overlap.
<Example>
1st. preheat time: 2:00 AM
2nd. preheat time: 3:00 AM
With the above settings, night-time preheating
will occur from 2:00 AM to 4:00 AM (2 hours).
4
Click [OK].
• Operation returns to the “4 Setup and
Maintenance” screen.
distributed by www.minilablaser.com